Search

Find a vulnerability

Search criteria

    82 vulnerabilities found for modicon_m580_firmware by schneider-electric

    CVE-2023-25620 (GCVE-0-2023-25620)

    Vulnerability from nvd – Published: 2023-04-19 08:17 – Updated: 2025-02-05 14:58
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Date Public
    2023-04-10 18:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.224Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25620",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T14:57:44.416842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T14:58:06.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to SV3.51"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to V4.10"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All "
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "datePublic": "2023-04-10T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
                }
              ],
              "value": "\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-12T03:15:17.732Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-25620",
        "datePublished": "2023-04-19T08:17:57.240Z",
        "dateReserved": "2023-02-09T13:42:27.387Z",
        "dateUpdated": "2025-02-05T14:58:06.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25619 (GCVE-0-2023-25619)

    Vulnerability from nvd – Published: 2023-04-19 07:53 – Updated: 2025-02-05 15:08
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Date Public
    2023-04-10 18:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.427Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25619",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T15:07:54.659345Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-754",
                    "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T15:08:51.526Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to SV3.51"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to V4.10"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All "
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "datePublic": "2023-04-10T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
                }
              ],
              "value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-12T03:15:17.732Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-25619",
        "datePublished": "2023-04-19T07:53:15.405Z",
        "dateReserved": "2023-02-09T13:42:27.387Z",
        "dateUpdated": "2025-02-05T15:08:51.526Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7475 (GCVE-0-2020-7475)

    Vulnerability from nvd – Published: 2020-03-23 18:56 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10) Affected: EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:18.769Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-23T18:56:18.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7475",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01",
                  "refsource": "MISC",
                  "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7475",
        "datePublished": "2020-03-23T18:56:18.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:18.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6857 (GCVE-0-2019-6857)

    Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:41
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.438Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6857",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:39:16.673211Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:41:14.779Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-21T23:03:43.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6857",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6857",
        "datePublished": "2020-01-06T22:57:05.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:41:14.779Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-6856 (GCVE-0-2019-6856)

    Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:37
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6856",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:36:59.205058Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:37:57.750Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-21T23:04:36.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6856",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6856",
        "datePublished": "2020-01-06T22:57:02.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:37:57.750Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2018-7794 (GCVE-0-2018-7794)

    Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.272Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-7794",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:08.954870Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:11.611Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-06T22:57:09.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7794",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7794",
        "datePublished": "2020-01-06T22:57:09.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:11.611Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-6851 (GCVE-0-2019-6851)

    Vulnerability from nvd – Published: 2019-10-29 14:55 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-538 - File and Directory Information Exposure
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.388Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-538",
                  "description": "CWE-538: File and Directory Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:55:35.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6851",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-538: File and Directory Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6851",
        "datePublished": "2019-10-29T14:55:35.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.388Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6850 (GCVE-0-2019-6850)

    Vulnerability from nvd – Published: 2019-10-29 14:54 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 Affected: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.356Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:54:39.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6850",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200: Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6850",
        "datePublished": "2019-10-29T14:54:39.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.356Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6849 (GCVE-0-2019-6849)

    Vulnerability from nvd – Published: 2019-10-29 14:53 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 Affected: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:53:44.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6849",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200: Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6849",
        "datePublished": "2019-10-29T14:53:44.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6848 (GCVE-0-2019-6848)

    Vulnerability from nvd – Published: 2019-10-29 14:53 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info) Affected: Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:18:21.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6848",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6848",
        "datePublished": "2019-10-29T14:53:10.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6847 (GCVE-0-2019-6847)

    Vulnerability from nvd – Published: 2019-10-29 14:52 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.413Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:18:02.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6847",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6847",
        "datePublished": "2019-10-29T14:52:24.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6846 (GCVE-0-2019-6846)

    Vulnerability from nvd – Published: 2019-10-29 14:51 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:51:31.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6846",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6846",
        "datePublished": "2019-10-29T14:51:31.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6845 (GCVE-0-2019-6845)

    Vulnerability from nvd – Published: 2019-10-29 14:49 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:49:49.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6845",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6845",
        "datePublished": "2019-10-29T14:49:49.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.391Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6844 (GCVE-0-2019-6844)

    Vulnerability from nvd – Published: 2019-10-29 14:48 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.430Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:17:33.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6844",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6844",
        "datePublished": "2019-10-29T14:48:44.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.430Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6843 (GCVE-0-2019-6843)

    Vulnerability from nvd – Published: 2019-10-29 14:48 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.371Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:17:13.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6843",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6843",
        "datePublished": "2019-10-29T14:48:04.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.371Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6842 (GCVE-0-2019-6842)

    Vulnerability from nvd – Published: 2019-10-29 14:47 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.358Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:16:32.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6842",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6842",
        "datePublished": "2019-10-29T14:47:16.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.358Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6841 (GCVE-0-2019-6841)

    Vulnerability from nvd – Published: 2019-10-29 14:46 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.395Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:16:12.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6841",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6841",
        "datePublished": "2019-10-29T14:46:24.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.395Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25620 (GCVE-0-2023-25620)

    Vulnerability from cvelistv5 – Published: 2023-04-19 08:17 – Updated: 2025-02-05 14:58
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Date Public
    2023-04-10 18:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.224Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25620",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T14:57:44.416842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T14:58:06.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to SV3.51"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to V4.10"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All "
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "datePublic": "2023-04-10T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
                }
              ],
              "value": "\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-12T03:15:17.732Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-25620",
        "datePublished": "2023-04-19T08:17:57.240Z",
        "dateReserved": "2023-02-09T13:42:27.387Z",
        "dateUpdated": "2025-02-05T14:58:06.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25619 (GCVE-0-2023-25619)

    Vulnerability from cvelistv5 – Published: 2023-04-19 07:53 – Updated: 2025-02-05 15:08
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Date Public
    2023-04-10 18:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.427Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25619",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T15:07:54.659345Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-754",
                    "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T15:08:51.526Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to SV3.51"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "prior to V4.10"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All "
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "datePublic": "2023-04-10T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
                }
              ],
              "value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-12T03:15:17.732Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-25619",
        "datePublished": "2023-04-19T07:53:15.405Z",
        "dateReserved": "2023-02-09T13:42:27.387Z",
        "dateUpdated": "2025-02-05T15:08:51.526Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7475 (GCVE-0-2020-7475)

    Vulnerability from cvelistv5 – Published: 2020-03-23 18:56 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10) Affected: EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:18.769Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-23T18:56:18.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7475",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01",
                  "refsource": "MISC",
                  "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7475",
        "datePublished": "2020-03-23T18:56:18.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:18.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7794 (GCVE-0-2018-7794)

    Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.272Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-7794",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:08.954870Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:11.611Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-06T22:57:09.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7794",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7794",
        "datePublished": "2020-01-06T22:57:09.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:11.611Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-6857 (GCVE-0-2019-6857)

    Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:41
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.438Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6857",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:39:16.673211Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:41:14.779Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-21T23:03:43.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6857",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6857",
        "datePublished": "2020-01-06T22:57:05.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:41:14.779Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-6856 (GCVE-0-2019-6856)

    Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:37
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
    Affected: Modicon M340
    Affected: Modicon Quantum
    Affected: Modicon Premium (see security notification for specific versions)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6856",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:36:59.205058Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:37:57.750Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
              "vendor": "Schneider Electric SE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580"
                },
                {
                  "status": "affected",
                  "version": "Modicon M340"
                },
                {
                  "status": "affected",
                  "version": "Modicon Quantum"
                },
                {
                  "status": "affected",
                  "version": "Modicon Premium (see security notification for specific versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-21T23:04:36.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6856",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580"
                              },
                              {
                                "version_value": "Modicon M340"
                              },
                              {
                                "version_value": "Modicon Quantum"
                              },
                              {
                                "version_value": "Modicon Premium (see security notification for specific versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric SE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6856",
        "datePublished": "2020-01-06T22:57:02.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:37:57.750Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-6851 (GCVE-0-2019-6851)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:55 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-538 - File and Directory Information Exposure
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.388Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-538",
                  "description": "CWE-538: File and Directory Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:55:35.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6851",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-538: File and Directory Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6851",
        "datePublished": "2019-10-29T14:55:35.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.388Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6850 (GCVE-0-2019-6850)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:54 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 Affected: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.356Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:54:39.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6850",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200: Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6850",
        "datePublished": "2019-10-29T14:54:39.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.356Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6849 (GCVE-0-2019-6849)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:53 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 Affected: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:53:44.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6849",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200: Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6849",
        "datePublished": "2019-10-29T14:53:44.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6848 (GCVE-0-2019-6848)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:53 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info) Affected: Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:18:21.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6848",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6848",
        "datePublished": "2019-10-29T14:53:10.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6847 (GCVE-0-2019-6847)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:52 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-755 - Improper Handling of Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Affected: Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.413Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755: Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-19T12:18:02.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6847",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-755: Improper Handling of Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6847",
        "datePublished": "2019-10-29T14:52:24.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6846 (GCVE-0-2019-6846)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:51 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:51:31.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6846",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6846",
        "datePublished": "2019-10-29T14:51:31.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6845 (GCVE-0-2019-6845)

    Vulnerability from cvelistv5 – Published: 2019-10-29 14:49 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.
    Severity
    No CVSS data available.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions) Affected: Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-29T14:49:49.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6845",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6845",
        "datePublished": "2019-10-29T14:49:49.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.391Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",