    CVE-2025-13902 (GCVE-0-2025-13902)

    Vulnerability from nvd – Published: 2026-03-10 17:06 – Updated: 2026-03-10 18:19
    VLAI
    Summary
    CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13902",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T18:17:03.131045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T18:19:19.395Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M241/M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.13.12"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M258/LMC058",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
                }
              ],
              "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T17:11:39.985Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2025-13902",
        "datePublished": "2026-03-10T17:06:00.208Z",
        "dateReserved": "2025-12-02T16:20:41.599Z",
        "dateUpdated": "2026-03-10T18:19:19.395Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13901 (GCVE-0-2025-13901)

    Vulnerability from nvd – Published: 2026-03-10 17:02 – Updated: 2026-03-10 17:25
    VLAI
    Summary
    CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-404 - Improper Resource Shutdown or Release
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Modicon M241/M251 Affected: Versions prior to 5.4.13.12
    Create a notification for this product.
    Schneider Electric Modicon M262 Affected: Versions prior to 5.4.10.12
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T17:24:36.387715Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T17:25:20.028Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M241/M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.13.12"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M262",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.10.12"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
                }
              ],
              "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-404",
                  "description": "CWE-404 Improper Resource Shutdown or Release",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T17:12:53.896Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2025-13901",
        "datePublished": "2026-03-10T17:02:22.998Z",
        "dateReserved": "2025-12-02T16:20:27.551Z",
        "dateUpdated": "2026-03-10T17:25:20.028Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-6528 (GCVE-0-2024-6528)

    Vulnerability from nvd – Published: 2024-07-11 09:03 – Updated: 2024-08-01 21:41
    VLAI
    Summary
    CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-6528",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-29T20:04:30.600996Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-29T20:04:38.247Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:41:03.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M241 / M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M258 / LMC058",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M262",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload.\n\n"
                }
              ],
              "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-11T09:03:27.074Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-6528",
        "datePublished": "2024-07-11T09:03:27.074Z",
        "dateReserved": "2024-07-05T09:35:52.875Z",
        "dateUpdated": "2024-08-01T21:41:03.525Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22699 (GCVE-0-2021-22699)

    Vulnerability from nvd – Published: 2021-05-26 19:19 – Updated: 2024-08-03 18:51
    VLAI
    Summary
    Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 Affected: Modicon M241/M251 logic controllers firmware prior to V5.1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.223Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-26T19:19:13.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2021-22699",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20: Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05",
                  "refsource": "MISC",
                  "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22699",
        "datePublished": "2021-05-26T19:19:13.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-03T18:51:07.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7488 (GCVE-0-2020-7488)

    Vulnerability from nvd – Published: 2020-04-22 18:51 – Updated: 2026-05-28 20:29
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions) Affected: EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.616Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-7488",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T20:28:35.740115Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T20:29:31.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-22T18:51:26.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7488",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7488",
        "datePublished": "2020-04-22T18:51:26.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2026-05-28T20:29:31.517Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-7487 (GCVE-0-2020-7487)

    Vulnerability from nvd – Published: 2020-04-22 18:50 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.
    Severity
    No CVSS data available.
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions) Affected: EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:18.793Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345: Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-22T18:50:25.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7487",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-345: Insufficient Verification of Data Authenticity"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7487",
        "datePublished": "2020-04-22T18:50:25.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:18.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6820 (GCVE-0-2019-6820)

    Vulnerability from nvd – Published: 2019-05-22 19:40 – Updated: 2026-05-28 19:28
    VLAI
    Summary
    A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 Affected: Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.357Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6820",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T19:28:33.142905Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T19:28:52.915Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T19:40:20.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6820",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6820",
        "datePublished": "2019-05-22T19:40:20.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-28T19:28:52.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2017-6030 (GCVE-0-2017-6030)

    Vulnerability from nvd – Published: 2017-06-30 02:35 – Updated: 2026-06-04 21:40
    VLAI
    Title
    Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
    Summary
    A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Date Public
    2017-06-29 00:00
    Credits
    David Formby and Raheem Beyah of Georgia Tech and Fortiphyd Logic, Inc. reported the identified vulnerabilities.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.582Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2017-6030",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:20:18.684514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:22:59.394Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M221",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "1.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M241",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "4.0.5.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "4.0.5.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "David Formby and Raheem Beyah of Georgia Tech and Fortiphyd Logic, Inc. reported the identified vulnerabilities."
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\u003c/p\u003e"
                }
              ],
              "value": "A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-343",
                  "description": "CWE-343",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-04T21:40:02.867Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-089-02.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\u003c/p\u003e\u003cp\u003eSoMachineBasic, Version 1.5, is available at the following location:\u003c/p\u003e\u003cp\u003ehttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u0026nbsp;\u003c/p\u003e\u003cp\u003eSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\u003c/p\u003e\u003cul\u003e\u003cli\u003eVerify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\u003c/li\u003e\u003cli\u003eLimit traffic on the local network with managed switches\u003c/li\u003e\u003cli\u003eWhere possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\u003c/li\u003e\u003cli\u003eDo not grant [network] access to unknown computers\u003c/li\u003e\u003cli\u003eWhen remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Schneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\n\n\n\nSoMachineBasic, Version 1.5, is available at the following location:\n\n\n\nhttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u00a0\n\n\n\nSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\n\n  *  Verify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\n  *  Limit traffic on the local network with managed switches\n  *  Where possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\n  *  Do not grant [network] access to unknown computers\n  *  When remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\n\n\n\n\nSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/"
            }
          ],
          "source": {
            "advisory": "ICSA-17-089-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric Modicon PLCs Predictable Value Range from Previous Values",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6030",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-343"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6030",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2026-06-04T21:40:02.867Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2017-6028 (GCVE-0-2017-6028)

    Vulnerability from nvd – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
    VLAI
    Summary
    An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modicon PLCs Affected: Schneider Electric Modicon PLCs
    Date Public
    2017-06-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.367Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modicon PLCs",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modicon PLCs"
                }
              ]
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-06-30T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6028",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-522"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6028",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2024-08-05T15:18:49.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-6026 (GCVE-0-2017-6026)

    Vulnerability from nvd – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
    VLAI
    Summary
    A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modicon PLCs Affected: Schneider Electric Modicon PLCs
    Date Public
    2017-06-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.435Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              },
              {
                "name": "45918",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45918/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modicon PLCs",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modicon PLCs"
                }
              ]
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-330",
                  "description": "CWE-330",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-12-01T10:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            },
            {
              "name": "45918",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45918/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6026",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-330"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                },
                {
                  "name": "45918",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45918/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6026",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2024-08-05T15:18:49.435Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-13902 (GCVE-0-2025-13902)

    Vulnerability from cvelistv5 – Published: 2026-03-10 17:06 – Updated: 2026-03-10 18:19
    VLAI
    Summary
    CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13902",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T18:17:03.131045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T18:19:19.395Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M241/M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.13.12"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M258/LMC058",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
                }
              ],
              "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T17:11:39.985Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2025-13902",
        "datePublished": "2026-03-10T17:06:00.208Z",
        "dateReserved": "2025-12-02T16:20:41.599Z",
        "dateUpdated": "2026-03-10T18:19:19.395Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13901 (GCVE-0-2025-13901)

    Vulnerability from cvelistv5 – Published: 2026-03-10 17:02 – Updated: 2026-03-10 17:25
    VLAI
    Summary
    CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-404 - Improper Resource Shutdown or Release
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Modicon M241/M251 Affected: Versions prior to 5.4.13.12
    Create a notification for this product.
    Schneider Electric Modicon M262 Affected: Versions prior to 5.4.10.12
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T17:24:36.387715Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T17:25:20.028Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M241/M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.13.12"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M262",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 5.4.10.12"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
                }
              ],
              "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-404",
                  "description": "CWE-404 Improper Resource Shutdown or Release",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T17:12:53.896Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2025-13901",
        "datePublished": "2026-03-10T17:02:22.998Z",
        "dateReserved": "2025-12-02T16:20:27.551Z",
        "dateUpdated": "2026-03-10T17:25:20.028Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-6528 (GCVE-0-2024-6528)

    Vulnerability from cvelistv5 – Published: 2024-07-11 09:03 – Updated: 2024-08-01 21:41
    VLAI
    Summary
    CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-6528",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-29T20:04:30.600996Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-29T20:04:38.247Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:41:03.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M241 / M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M258 / LMC058",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Controllers M262",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload.\n\n"
                }
              ],
              "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-11T09:03:27.074Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-6528",
        "datePublished": "2024-07-11T09:03:27.074Z",
        "dateReserved": "2024-07-05T09:35:52.875Z",
        "dateUpdated": "2024-08-01T21:41:03.525Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22699 (GCVE-0-2021-22699)

    Vulnerability from cvelistv5 – Published: 2021-05-26 19:19 – Updated: 2024-08-03 18:51
    VLAI
    Summary
    Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 Affected: Modicon M241/M251 logic controllers firmware prior to V5.1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.223Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-26T19:19:13.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2021-22699",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M241/M251 logic controllers firmware prior to V5.1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20: Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05",
                  "refsource": "MISC",
                  "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22699",
        "datePublished": "2021-05-26T19:19:13.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-03T18:51:07.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7488 (GCVE-0-2020-7488)

    Vulnerability from cvelistv5 – Published: 2020-04-22 18:51 – Updated: 2026-05-28 20:29
    VLAI
    Summary
    A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions) Affected: EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.616Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-7488",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T20:28:35.740115Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T20:29:31.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319: Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-22T18:51:26.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7488",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7488",
        "datePublished": "2020-04-22T18:51:26.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2026-05-28T20:29:31.517Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-7487 (GCVE-0-2020-7487)

    Vulnerability from cvelistv5 – Published: 2020-04-22 18:50 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.
    Severity
    No CVSS data available.
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions) Affected: EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:18.793Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345: Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-22T18:50:25.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7487",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-345: Insufficient Verification of Data Authenticity"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7487",
        "datePublished": "2020-04-22T18:50:25.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:18.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6820 (GCVE-0-2019-6820)

    Vulnerability from cvelistv5 – Published: 2019-05-22 19:40 – Updated: 2026-05-28 19:28
    VLAI
    Summary
    A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 Affected: Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.357Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-6820",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T19:28:33.142905Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T19:28:52.915Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T19:40:20.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6820",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6820",
        "datePublished": "2019-05-22T19:40:20.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2026-05-28T19:28:52.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2017-6030 (GCVE-0-2017-6030)

    Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2026-06-04 21:40
    VLAI
    Title
    Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
    Summary
    A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Date Public
    2017-06-29 00:00
    Credits
    David Formby and Raheem Beyah of Georgia Tech and Fortiphyd Logic, Inc. reported the identified vulnerabilities.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.582Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2017-6030",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:20:18.684514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:22:59.394Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M221",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "1.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M241",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "4.0.5.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M251",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "4.0.5.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "David Formby and Raheem Beyah of Georgia Tech and Fortiphyd Logic, Inc. reported the identified vulnerabilities."
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\u003c/p\u003e"
                }
              ],
              "value": "A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-343",
                  "description": "CWE-343",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-04T21:40:02.867Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-089-02.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\u003c/p\u003e\u003cp\u003eSoMachineBasic, Version 1.5, is available at the following location:\u003c/p\u003e\u003cp\u003ehttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u0026nbsp;\u003c/p\u003e\u003cp\u003eSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\u003c/p\u003e\u003cul\u003e\u003cli\u003eVerify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\u003c/li\u003e\u003cli\u003eLimit traffic on the local network with managed switches\u003c/li\u003e\u003cli\u003eWhere possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\u003c/li\u003e\u003cli\u003eDo not grant [network] access to unknown computers\u003c/li\u003e\u003cli\u003eWhen remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Schneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\n\n\n\nSoMachineBasic, Version 1.5, is available at the following location:\n\n\n\nhttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u00a0\n\n\n\nSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\n\n  *  Verify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\n  *  Limit traffic on the local network with managed switches\n  *  Where possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\n  *  Do not grant [network] access to unknown computers\n  *  When remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\n\n\n\n\nSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/"
            }
          ],
          "source": {
            "advisory": "ICSA-17-089-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric Modicon PLCs Predictable Value Range from Previous Values",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6030",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-343"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6030",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2026-06-04T21:40:02.867Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2017-6028 (GCVE-0-2017-6028)

    Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
    VLAI
    Summary
    An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modicon PLCs Affected: Schneider Electric Modicon PLCs
    Date Public
    2017-06-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.367Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modicon PLCs",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modicon PLCs"
                }
              ]
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-06-30T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6028",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-522"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6028",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2024-08-05T15:18:49.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-6026 (GCVE-0-2017-6026)

    Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
    VLAI
    Summary
    A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modicon PLCs Affected: Schneider Electric Modicon PLCs
    Date Public
    2017-06-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:18:49.435Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
              },
              {
                "name": "97254",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97254"
              },
              {
                "name": "45918",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45918/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modicon PLCs",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modicon PLCs"
                }
              ]
            }
          ],
          "datePublic": "2017-06-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-330",
                  "description": "CWE-330",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-12-01T10:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
            },
            {
              "name": "97254",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97254"
            },
            {
              "name": "45918",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45918/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2017-6026",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modicon PLCs",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modicon PLCs"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-330"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
                },
                {
                  "name": "97254",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97254"
                },
                {
                  "name": "45918",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45918/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2017-6026",
        "datePublished": "2017-06-30T02:35:00.000Z",
        "dateReserved": "2017-02-16T00:00:00.000Z",
        "dateUpdated": "2024-08-05T15:18:49.435Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }