CVE-2020-28214 (GCVE-0-2020-28214)
Vulnerability from nvd – Published: 2020-12-11 00:51 – Updated: 2026-05-28 20:12
VLAI
Summary
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-760 - Use of a One-Way Hash with a Predictable Salt
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221 (all references, all versions) |
Affected:
Modicon M221 (all references, all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:58.330Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-28214",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:12:35.109774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:12:55.037Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221 (all references, all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221 (all references, all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-760",
"description": "CWE-760: Use of a One-Way Hash with a Predictable Salt",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:30:49.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-28214",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221 (all references, all versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M221 (all references, all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-760: Use of a One-Way Hash with a Predictable Salt"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-28214",
"datePublished": "2020-12-11T00:51:01.000Z",
"dateReserved": "2020-11-05T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:12:55.037Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7568 (GCVE-0-2020-7568)
Vulnerability from nvd – Published: 2020-11-19 21:10 – Updated: 2026-05-29 14:52
VLAI
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:50:47.160253Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:52:14.827Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:14.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7568",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7568",
"datePublished": "2020-11-19T21:10:33.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:52:14.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7567 (GCVE-0-2020-7567)
Vulnerability from nvd – Published: 2020-11-19 21:10 – Updated: 2026-05-29 14:49
VLAI
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.454Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:47:15.785310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:49:08.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:08.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7567",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-311: Missing Encryption of Sensitive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7567",
"datePublished": "2020-11-19T21:10:27.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:49:08.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7566 (GCVE-0-2020-7566)
Vulnerability from nvd – Published: 2020-11-19 21:10 – Updated: 2026-05-29 18:27
VLAI
Summary
A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-334 - Small Space of Random ValuesÊ
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T18:26:48.987306Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T18:27:20.594Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-334",
"description": "CWE-334: Small Space of Random Values\u00ca",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7566",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-334: Small Space of Random Values\u00ca"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7566",
"datePublished": "2020-11-19T21:10:22.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T18:27:20.594Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7565 (GCVE-0-2020-7565)
Vulnerability from nvd – Published: 2020-11-19 21:10 – Updated: 2026-05-29 13:28
VLAI
Summary
A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7565",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:27:45.918932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:28:02.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:30:55.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7565",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7565",
"datePublished": "2020-11-19T21:10:09.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:28:02.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7489 (GCVE-0-2020-7489)
Vulnerability from nvd – Published: 2020-04-22 18:15 – Updated: 2026-05-28 20:30
VLAI
Summary
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions) |
Affected:
SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.769Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7489",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:30:08.104474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:30:39.144Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027) vulnerability exists on EcoStruxure Machine Expert \u2013 Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T18:15:57.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7489",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027) vulnerability exists on EcoStruxure Machine Expert \u2013 Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7489",
"datePublished": "2020-04-22T18:15:57.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:30:39.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6820 (GCVE-0-2019-6820)
Vulnerability from nvd – Published: 2019-05-22 19:40 – Updated: 2026-05-28 19:28
VLAI
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 |
Affected:
Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.357Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6820",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T19:28:33.142905Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T19:28:52.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:40:20.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6820",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
"version": {
"version_data": [
{
"version_value": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6820",
"datePublished": "2019-05-22T19:40:20.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-28T19:28:52.915Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7823 (GCVE-0-2018-7823)
Vulnerability from nvd – Published: 2019-05-22 19:37 – Updated: 2024-08-05 06:37
VLAI
Summary
A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message.
Severity
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.690Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:37:45.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7823",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7823",
"datePublished": "2019-05-22T19:37:45.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.690Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7822 (GCVE-0-2018-7822)
Vulnerability from nvd – Published: 2019-05-22 19:37 – Updated: 2024-08-05 06:37
VLAI
Summary
An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic.
Severity
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.180Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:37:16.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7822",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7822",
"datePublished": "2019-05-22T19:37:16.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7821 (GCVE-0-2018-7821)
Vulnerability from nvd – Published: 2019-05-22 19:36 – Updated: 2026-05-29 14:12
VLAI
Summary
An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Multiple Vulnerabilities
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.137Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7821",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:10:11.118524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:12:29.726Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:36:47.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7821",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7821",
"datePublished": "2019-05-22T19:36:47.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:12:29.726Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-10953 (GCVE-0-2019-10953)
Vulnerability from nvd – Published: 2019-04-17 14:02 – Updated: 2026-06-04 18:42
VLAI
Summary
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION CWE-400
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03 | |
| http://www.securityfocus.com/bid/108413 | vdb-entryx_refsource_BID |
| https://github.com/cisagov/CSAF/blob/develop/csaf… |
Impacted products
12 products
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | 1SAP120600R0071 PM554-TP-ETH |
Affected:
Multiple
|
|
| Phoenix Contact | 2700974 ILC 151 ETH |
Affected:
Multiple
|
|
| Phoenix Contact | ILC 191 ETH 2TX |
Affected:
Multiple
|
|
| Schneider Electric | Modicon M221 |
Affected:
0 , < v1.10.0.0
(custom)
Unaffected: v1.10.0.0 |
|
| Schneider Electric | EcoStruxure Machine Expert – Basic |
Affected:
0 , < v1.0
(custom)
Unaffected: v1.0 |
|
| Siemens | 6ES7211-1AE40-0XB0 Simatic S7-1211 |
Unaffected:
Multiple
|
|
| Siemens | 6ES7314-6EH04-0AB0 Simatic S7-314 |
Unaffected:
Multiple
|
|
| Siemens | 6ED1052-1CC01-0BA8 Logo! 8 |
Unaffected:
Multiple
|
|
| WAGO | 750-889 Controller KNX IP |
Affected:
Multiple
|
|
| WAGO | 750-8100 Controller PFC100 |
Affected:
Multiple
|
|
| WAGO | 750-880 Controller ETH |
Affected:
Multiple
|
|
| WAGO | 750-831 Controller BACnet/IP |
Affected:
Multiple
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108413"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-10953",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:42:08.076750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:45:20.435Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1SAP120600R0071 PM554-TP-ETH",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "2700974 ILC 151 ETH",
"vendor": "Phoenix Contact",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC 191 ETH 2TX",
"vendor": "Phoenix Contact",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M221",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.10.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "v1.10.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Machine Expert \u2013 Basic",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "v1.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ES7211-1AE40-0XB0 Simatic S7-1211",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ES7314-6EH04-0AB0 Simatic S7-314",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ED1052-1CC01-0BA8 Logo! 8",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-889 Controller KNX IP",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-8100 Controller PFC100",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-880 Controller ETH",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-831 Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matthias Niedermaier (Hochschule Augsburg), Jan-Ole Malchow (Freie Universita\u0308t Berlin), and Florian Fischer (Hochschule Augsburg) reported this vulnerability to CISA."
},
{
"lang": "en",
"type": "finder",
"value": "Mikael Vingaard found and reported to CISA additional devices containing this vulnerability."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.\u003c/p\u003e"
}
],
"value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-04T18:42:43.045Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108413"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2019/icsa-19-106-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eFixes are available in\u0026nbsp; Schneider Electric\n\nModicon M221 firmware v1.10.0.0 and EcoStruxure Machine Expert \u2013 Basic v1.0 software (formerly SoMachine Basic) using either of the following options:\u003cbr\u003e\u003cbr\u003eUse this link to download the Machine Expert Basic software.\u003c/p\u003e\u003cp\u003eOr run the Schneider Electric Software Update tool in order to download and install EcoStruxure Machine Expert \u2013 Basic v1.0 software.\u003c/p\u003e\u003cp\u003eFor additional information, see the Schneider Electric security notice SEVD-2019-045-01. (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-045-01)\u003c/p\u003e\u003cp\u003eSchneider Electric strongly recommends following industry cybersecurity best practices, such as:\u003c/p\u003e\u003cul\u003e\u003cli\u003ePhysical controls should be in place so no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.\u003c/li\u003e\u003cli\u003eAll controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.\u003c/li\u003e\u003cli\u003eAll programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices it is intended.\u003c/li\u003e\u003cli\u003eAll methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) should be scanned before use in terminals or any node connected to these networks.\u003c/li\u003e\u003cli\u003eLaptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Fixes are available in\u00a0 Schneider Electric\n\nModicon M221 firmware v1.10.0.0 and EcoStruxure Machine Expert \u2013 Basic v1.0 software (formerly SoMachine Basic) using either of the following options:\n\nUse this link to download the Machine Expert Basic software.\n\n\n\nOr run the Schneider Electric Software Update tool in order to download and install EcoStruxure Machine Expert \u2013 Basic v1.0 software.\n\n\n\nFor additional information, see the Schneider Electric security notice SEVD-2019-045-01. (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-045-01)\n\n\n\nSchneider Electric strongly recommends following industry cybersecurity best practices, such as:\n\n * Physical controls should be in place so no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.\n * All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.\n * All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices it is intended.\n * All methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) should be scanned before use in terminals or any node connected to these networks.\n * Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation."
}
],
"source": {
"advisory": "ICSA-19-106-03",
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eABB concludes the reported behavior is not a vulnerability but is due to a misconfiguration of the PLC watchdog, which was left in the default factory settings. This has led to a configuration that does not match the expectations expressed in the test cases and the result is the PLC not reacting as intended. This misconfiguration can be fixed by setting an appropriate combination of task priority, task cycle time, and watchdog settings. Please see the \u201cOnboard Ethernet Handling in CPU Firmware\u201d chapter (System Technology for AC500 V2 Products \u0026gt; System Technology of CPU and Overall System \u0026gt; Onboard Technologies \u0026gt; Ethernet \u0026gt; Ethernet Protocols and Ports for AC500 V2 Products \u0026gt; Onboard Ethernet Handling in CPU Firmware) for further guidance.\u003c/span\u003e"
}
],
"value": "ABB concludes the reported behavior is not a vulnerability but is due to a misconfiguration of the PLC watchdog, which was left in the default factory settings. This has led to a configuration that does not match the expectations expressed in the test cases and the result is the PLC not reacting as intended. This misconfiguration can be fixed by setting an appropriate combination of task priority, task cycle time, and watchdog settings. Please see the \u201cOnboard Ethernet Handling in CPU Firmware\u201d chapter (System Technology for AC500 V2 Products \u003e System Technology of CPU and Overall System \u003e Onboard Technologies \u003e Ethernet \u003e Ethernet Protocols and Ports for AC500 V2 Products \u003e Onboard Ethernet Handling in CPU Firmware) for further guidance."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhoenix Contact acknowledges this as a \u201cknown, won\u2019t fix\u201d issue for old products. Currently available products provide countermeasures to mitigate the impact on the safety-related functionality. Phoenix Contact urges users to adhere to the\u0026nbsp;Application note 107913_en_01.\u003c/p\u003e\u003cp\u003eMore information can be found in the\u003cspan\u003e\u0026nbsp;\u003c/span\u003e\u003ca href=\"https://cert.vde.com/en-us/advisories/vde-2018-012\"\u003eVDE CERT advisory\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Phoenix Contact acknowledges this as a \u201cknown, won\u2019t fix\u201d issue for old products. Currently available products provide countermeasures to mitigate the impact on the safety-related functionality. Phoenix Contact urges users to adhere to the\u00a0Application note 107913_en_01.\n\n\n\nMore information can be found in the\u00a0 VDE CERT advisory https://cert.vde.com/en-us/advisories/vde-2018-012 ."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eSiemens has investigated the vulnerability report on PLC cycle time influences and concludes the report does not demonstrate a valid vulnerability for Siemens PLCs.\u003c/span\u003e"
}
],
"value": "Siemens has investigated the vulnerability report on PLC cycle time influences and concludes the report does not demonstrate a valid vulnerability for Siemens PLCs."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWAGO recommends users operate the devices in closed networks or protect them with a firewall against unauthorized access. Another recommended mitigation is to limit network traffic via the switch rate limit feature according to application needs.\u003c/span\u003e\u003cbr\u003e\u003cspan\u003ePlease also consult the product manuals on the WAGO website, as this is a known problem for some devices. Links to product manuals and specific instructions about how to limit switch rates can be found in the\u003cspan\u003e\u0026nbsp;\u003c/span\u003e\u003c/span\u003e\u003ca href=\"https://cert.vde.com/de-de/advisories/vde-2018-013\"\u003eVDE CERT advisory\u003c/a\u003e\u003cspan\u003e.\u003c/span\u003e"
}
],
"value": "WAGO recommends users operate the devices in closed networks or protect them with a firewall against unauthorized access. Another recommended mitigation is to limit network traffic via the switch rate limit feature according to application needs.\nPlease also consult the product manuals on the WAGO website, as this is a known problem for some devices. Links to product manuals and specific instructions about how to limit switch rates can be found in the\u00a0 VDE CERT advisory https://cert.vde.com/de-de/advisories/vde-2018-013 ."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.2"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-10953",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers",
"version": {
"version_data": [
{
"version_value": "Multiple"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108413"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-10953",
"datePublished": "2019-04-17T14:02:15.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2026-06-04T18:42:43.045Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7792 (GCVE-0-2018-7792)
Vulnerability from nvd – Published: 2018-08-29 21:00 – Updated: 2026-05-29 14:03
VLAI
Summary
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Permissions, Privileges, and Access Control
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.723Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:01:27.327782Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:03:17.593Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Permissions, Privileges, and Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7792",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Permissions, Privileges, and Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7792",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:03:17.593Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7791 (GCVE-0-2018-7791)
Vulnerability from nvd – Published: 2018-08-29 21:00 – Updated: 2026-05-29 13:59
VLAI
Summary
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Permissions, Privileges, and Access Control
- CWE-284 - Improper Access Control
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7791",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:56:29.398277Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:59:17.157Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Permissions, Privileges, and Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7791",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Permissions, Privileges, and Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7791",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:59:17.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7790 (GCVE-0-2018-7790)
Vulnerability from nvd – Published: 2018-08-29 21:00 – Updated: 2026-05-29 13:55
VLAI
Summary
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Information Management Error
- CWE-294 - Authentication Bypass by Capture-replay
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.565Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7790",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:52:53.696411Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:55:56.843Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Information Management Error vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Management Error",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7790",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Information Management Error vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Management Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7790",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:55:56.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7789 (GCVE-0-2018-7789)
Vulnerability from nvd – Published: 2018-08-29 20:00 – Updated: 2026-05-29 13:50
VLAI
Summary
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.
Severity
4.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Improper Check for Unusual or Exceptional Conditions
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02 | x_refsource_MISC |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/105171 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.299Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105171"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:42:20.871154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:50:59.507Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-30T19:57:02.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105171"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-21T00:00:00",
"ID": "CVE-2018-7789",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105171"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7789",
"datePublished": "2018-08-29T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:50:59.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-28214 (GCVE-0-2020-28214)
Vulnerability from cvelistv5 – Published: 2020-12-11 00:51 – Updated: 2026-05-28 20:12
VLAI
Summary
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-760 - Use of a One-Way Hash with a Predictable Salt
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221 (all references, all versions) |
Affected:
Modicon M221 (all references, all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:58.330Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-28214",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:12:35.109774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:12:55.037Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221 (all references, all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221 (all references, all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-760",
"description": "CWE-760: Use of a One-Way Hash with a Predictable Salt",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:30:49.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-28214",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221 (all references, all versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M221 (all references, all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-760: Use of a One-Way Hash with a Predictable Salt"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-28214",
"datePublished": "2020-12-11T00:51:01.000Z",
"dateReserved": "2020-11-05T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:12:55.037Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7568 (GCVE-0-2020-7568)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:10 – Updated: 2026-05-29 14:52
VLAI
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:50:47.160253Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:52:14.827Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:14.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7568",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7568",
"datePublished": "2020-11-19T21:10:33.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:52:14.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7567 (GCVE-0-2020-7567)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:10 – Updated: 2026-05-29 14:49
VLAI
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.454Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:47:15.785310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:49:08.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:08.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7567",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-311: Missing Encryption of Sensitive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7567",
"datePublished": "2020-11-19T21:10:27.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:49:08.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7566 (GCVE-0-2020-7566)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:10 – Updated: 2026-05-29 18:27
VLAI
Summary
A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-334 - Small Space of Random ValuesÊ
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T18:26:48.987306Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T18:27:20.594Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-334",
"description": "CWE-334: Small Space of Random Values\u00ca",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:31:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7566",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-334: Small Space of Random Values\u00ca"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7566",
"datePublished": "2020-11-19T21:10:22.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T18:27:20.594Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7565 (GCVE-0-2020-7565)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:10 – Updated: 2026-05-29 13:28
VLAI
Summary
A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7565",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:27:45.918932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:28:02.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:30:55.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7565",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7565",
"datePublished": "2020-11-19T21:10:09.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:28:02.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-7489 (GCVE-0-2020-7489)
Vulnerability from cvelistv5 – Published: 2020-04-22 18:15 – Updated: 2026-05-28 20:30
VLAI
Summary
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions) |
Affected:
SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.769Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7489",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:30:08.104474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:30:39.144Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027) vulnerability exists on EcoStruxure Machine Expert \u2013 Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T18:15:57.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7489",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027) vulnerability exists on EcoStruxure Machine Expert \u2013 Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7489",
"datePublished": "2020-04-22T18:15:57.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:30:39.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6820 (GCVE-0-2019-6820)
Vulnerability from cvelistv5 – Published: 2019-05-22 19:40 – Updated: 2026-05-28 19:28
VLAI
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 |
Affected:
Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.357Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6820",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T19:28:33.142905Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T19:28:52.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:40:20.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6820",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
"version": {
"version_data": [
{
"version_value": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6820",
"datePublished": "2019-05-22T19:40:20.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-28T19:28:52.915Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7823 (GCVE-0-2018-7823)
Vulnerability from cvelistv5 – Published: 2019-05-22 19:37 – Updated: 2024-08-05 06:37
VLAI
Summary
A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message.
Severity
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.690Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:37:45.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7823",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7823",
"datePublished": "2019-05-22T19:37:45.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.690Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7822 (GCVE-0-2018-7822)
Vulnerability from cvelistv5 – Published: 2019-05-22 19:37 – Updated: 2024-08-05 06:37
VLAI
Summary
An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic.
Severity
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.180Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:37:16.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7822",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7822",
"datePublished": "2019-05-22T19:37:16.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7821 (GCVE-0-2018-7821)
Vulnerability from cvelistv5 – Published: 2019-05-22 19:36 – Updated: 2026-05-29 14:12
VLAI
Summary
An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Multiple Vulnerabilities
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0 |
Affected:
SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.137Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7821",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:10:11.118524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:12:29.726Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:36:47.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7821",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0",
"version": {
"version_data": [
{
"version_value": "SoMachine Basic and Modicon M221, SoMachine Basic, all versions Modicon M221, all references, all versions prior to firmware V1.10.0.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7821",
"datePublished": "2019-05-22T19:36:47.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:12:29.726Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-10953 (GCVE-0-2019-10953)
Vulnerability from cvelistv5 – Published: 2019-04-17 14:02 – Updated: 2026-06-04 18:42
VLAI
Summary
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION CWE-400
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03 | |
| http://www.securityfocus.com/bid/108413 | vdb-entryx_refsource_BID |
| https://github.com/cisagov/CSAF/blob/develop/csaf… |
Impacted products
12 products
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | 1SAP120600R0071 PM554-TP-ETH |
Affected:
Multiple
|
|
| Phoenix Contact | 2700974 ILC 151 ETH |
Affected:
Multiple
|
|
| Phoenix Contact | ILC 191 ETH 2TX |
Affected:
Multiple
|
|
| Schneider Electric | Modicon M221 |
Affected:
0 , < v1.10.0.0
(custom)
Unaffected: v1.10.0.0 |
|
| Schneider Electric | EcoStruxure Machine Expert – Basic |
Affected:
0 , < v1.0
(custom)
Unaffected: v1.0 |
|
| Siemens | 6ES7211-1AE40-0XB0 Simatic S7-1211 |
Unaffected:
Multiple
|
|
| Siemens | 6ES7314-6EH04-0AB0 Simatic S7-314 |
Unaffected:
Multiple
|
|
| Siemens | 6ED1052-1CC01-0BA8 Logo! 8 |
Unaffected:
Multiple
|
|
| WAGO | 750-889 Controller KNX IP |
Affected:
Multiple
|
|
| WAGO | 750-8100 Controller PFC100 |
Affected:
Multiple
|
|
| WAGO | 750-880 Controller ETH |
Affected:
Multiple
|
|
| WAGO | 750-831 Controller BACnet/IP |
Affected:
Multiple
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108413"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-10953",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:42:08.076750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:45:20.435Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1SAP120600R0071 PM554-TP-ETH",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "2700974 ILC 151 ETH",
"vendor": "Phoenix Contact",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC 191 ETH 2TX",
"vendor": "Phoenix Contact",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M221",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.10.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "v1.10.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Machine Expert \u2013 Basic",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "v1.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ES7211-1AE40-0XB0 Simatic S7-1211",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ES7314-6EH04-0AB0 Simatic S7-314",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "6ED1052-1CC01-0BA8 Logo! 8",
"vendor": "Siemens",
"versions": [
{
"status": "unaffected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-889 Controller KNX IP",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-8100 Controller PFC100",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-880 Controller ETH",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-831 Controller BACnet/IP",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "Multiple"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matthias Niedermaier (Hochschule Augsburg), Jan-Ole Malchow (Freie Universita\u0308t Berlin), and Florian Fischer (Hochschule Augsburg) reported this vulnerability to CISA."
},
{
"lang": "en",
"type": "finder",
"value": "Mikael Vingaard found and reported to CISA additional devices containing this vulnerability."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.\u003c/p\u003e"
}
],
"value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-04T18:42:43.045Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108413"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2019/icsa-19-106-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eFixes are available in\u0026nbsp; Schneider Electric\n\nModicon M221 firmware v1.10.0.0 and EcoStruxure Machine Expert \u2013 Basic v1.0 software (formerly SoMachine Basic) using either of the following options:\u003cbr\u003e\u003cbr\u003eUse this link to download the Machine Expert Basic software.\u003c/p\u003e\u003cp\u003eOr run the Schneider Electric Software Update tool in order to download and install EcoStruxure Machine Expert \u2013 Basic v1.0 software.\u003c/p\u003e\u003cp\u003eFor additional information, see the Schneider Electric security notice SEVD-2019-045-01. (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-045-01)\u003c/p\u003e\u003cp\u003eSchneider Electric strongly recommends following industry cybersecurity best practices, such as:\u003c/p\u003e\u003cul\u003e\u003cli\u003ePhysical controls should be in place so no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.\u003c/li\u003e\u003cli\u003eAll controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.\u003c/li\u003e\u003cli\u003eAll programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices it is intended.\u003c/li\u003e\u003cli\u003eAll methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) should be scanned before use in terminals or any node connected to these networks.\u003c/li\u003e\u003cli\u003eLaptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Fixes are available in\u00a0 Schneider Electric\n\nModicon M221 firmware v1.10.0.0 and EcoStruxure Machine Expert \u2013 Basic v1.0 software (formerly SoMachine Basic) using either of the following options:\n\nUse this link to download the Machine Expert Basic software.\n\n\n\nOr run the Schneider Electric Software Update tool in order to download and install EcoStruxure Machine Expert \u2013 Basic v1.0 software.\n\n\n\nFor additional information, see the Schneider Electric security notice SEVD-2019-045-01. (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-045-01)\n\n\n\nSchneider Electric strongly recommends following industry cybersecurity best practices, such as:\n\n * Physical controls should be in place so no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.\n * All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.\n * All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices it is intended.\n * All methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) should be scanned before use in terminals or any node connected to these networks.\n * Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation."
}
],
"source": {
"advisory": "ICSA-19-106-03",
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eABB concludes the reported behavior is not a vulnerability but is due to a misconfiguration of the PLC watchdog, which was left in the default factory settings. This has led to a configuration that does not match the expectations expressed in the test cases and the result is the PLC not reacting as intended. This misconfiguration can be fixed by setting an appropriate combination of task priority, task cycle time, and watchdog settings. Please see the \u201cOnboard Ethernet Handling in CPU Firmware\u201d chapter (System Technology for AC500 V2 Products \u0026gt; System Technology of CPU and Overall System \u0026gt; Onboard Technologies \u0026gt; Ethernet \u0026gt; Ethernet Protocols and Ports for AC500 V2 Products \u0026gt; Onboard Ethernet Handling in CPU Firmware) for further guidance.\u003c/span\u003e"
}
],
"value": "ABB concludes the reported behavior is not a vulnerability but is due to a misconfiguration of the PLC watchdog, which was left in the default factory settings. This has led to a configuration that does not match the expectations expressed in the test cases and the result is the PLC not reacting as intended. This misconfiguration can be fixed by setting an appropriate combination of task priority, task cycle time, and watchdog settings. Please see the \u201cOnboard Ethernet Handling in CPU Firmware\u201d chapter (System Technology for AC500 V2 Products \u003e System Technology of CPU and Overall System \u003e Onboard Technologies \u003e Ethernet \u003e Ethernet Protocols and Ports for AC500 V2 Products \u003e Onboard Ethernet Handling in CPU Firmware) for further guidance."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhoenix Contact acknowledges this as a \u201cknown, won\u2019t fix\u201d issue for old products. Currently available products provide countermeasures to mitigate the impact on the safety-related functionality. Phoenix Contact urges users to adhere to the\u0026nbsp;Application note 107913_en_01.\u003c/p\u003e\u003cp\u003eMore information can be found in the\u003cspan\u003e\u0026nbsp;\u003c/span\u003e\u003ca href=\"https://cert.vde.com/en-us/advisories/vde-2018-012\"\u003eVDE CERT advisory\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Phoenix Contact acknowledges this as a \u201cknown, won\u2019t fix\u201d issue for old products. Currently available products provide countermeasures to mitigate the impact on the safety-related functionality. Phoenix Contact urges users to adhere to the\u00a0Application note 107913_en_01.\n\n\n\nMore information can be found in the\u00a0 VDE CERT advisory https://cert.vde.com/en-us/advisories/vde-2018-012 ."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eSiemens has investigated the vulnerability report on PLC cycle time influences and concludes the report does not demonstrate a valid vulnerability for Siemens PLCs.\u003c/span\u003e"
}
],
"value": "Siemens has investigated the vulnerability report on PLC cycle time influences and concludes the report does not demonstrate a valid vulnerability for Siemens PLCs."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWAGO recommends users operate the devices in closed networks or protect them with a firewall against unauthorized access. Another recommended mitigation is to limit network traffic via the switch rate limit feature according to application needs.\u003c/span\u003e\u003cbr\u003e\u003cspan\u003ePlease also consult the product manuals on the WAGO website, as this is a known problem for some devices. Links to product manuals and specific instructions about how to limit switch rates can be found in the\u003cspan\u003e\u0026nbsp;\u003c/span\u003e\u003c/span\u003e\u003ca href=\"https://cert.vde.com/de-de/advisories/vde-2018-013\"\u003eVDE CERT advisory\u003c/a\u003e\u003cspan\u003e.\u003c/span\u003e"
}
],
"value": "WAGO recommends users operate the devices in closed networks or protect them with a firewall against unauthorized access. Another recommended mitigation is to limit network traffic via the switch rate limit feature according to application needs.\nPlease also consult the product manuals on the WAGO website, as this is a known problem for some devices. Links to product manuals and specific instructions about how to limit switch rates can be found in the\u00a0 VDE CERT advisory https://cert.vde.com/de-de/advisories/vde-2018-013 ."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.2"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-10953",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers",
"version": {
"version_data": [
{
"version_value": "Multiple"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
},
{
"name": "108413",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108413"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-10953",
"datePublished": "2019-04-17T14:02:15.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2026-06-04T18:42:43.045Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7792 (GCVE-0-2018-7792)
Vulnerability from cvelistv5 – Published: 2018-08-29 21:00 – Updated: 2026-05-29 14:03
VLAI
Summary
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Permissions, Privileges, and Access Control
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.723Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:01:27.327782Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:03:17.593Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Permissions, Privileges, and Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7792",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Permissions, Privileges, and Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7792",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:03:17.593Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7791 (GCVE-0-2018-7791)
Vulnerability from cvelistv5 – Published: 2018-08-29 21:00 – Updated: 2026-05-29 13:59
VLAI
Summary
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Permissions, Privileges, and Access Control
- CWE-284 - Improper Access Control
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7791",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:56:29.398277Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:59:17.157Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Permissions, Privileges, and Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7791",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Permissions, Privileges, and Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7791",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:59:17.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7790 (GCVE-0-2018-7790)
Vulnerability from cvelistv5 – Published: 2018-08-29 21:00 – Updated: 2026-05-29 13:55
VLAI
Summary
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Information Management Error
- CWE-294 - Authentication Bypass by Capture-replay
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/105182 | vdb-entryx_refsource_BID |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.565Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7790",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:52:53.696411Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:55:56.843Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Information Management Error vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Management Error",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-31T09:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "105182",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105182"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-22T00:00:00",
"ID": "CVE-2018-7790",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Information Management Error vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Management Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105182",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105182"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-235-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7790",
"datePublished": "2018-08-29T21:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:55:56.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7789 (GCVE-0-2018-7789)
Vulnerability from cvelistv5 – Published: 2018-08-29 20:00 – Updated: 2026-05-29 13:50
VLAI
Summary
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.
Severity
4.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- Improper Check for Unusual or Exceptional Conditions
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02 | x_refsource_MISC |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/105171 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M221, all references, all versions prior to firmware V1.6.2.0 |
Affected:
Modicon M221, all references, all versions prior to firmware V1.6.2.0
|
Date Public
2018-08-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.299Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105171"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:42:20.871154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:50:59.507Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
],
"datePublic": "2018-08-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-30T19:57:02.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105171"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-08-21T00:00:00",
"ID": "CVE-2018-7789",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions prior to firmware V1.6.2.0",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions prior to firmware V1.6.2.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric\u0027s Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"
},
{
"name": "105171",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105171"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7789",
"datePublished": "2018-08-29T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:50:59.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}