Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for mmt-7306_firmware by medtronic

    FKIE_CVE-2022-32537

    Vulnerability from fkie_nvd - Published: 2022-12-12 13:15 - Updated: 2026-06-17 04:47
    Summary
    A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
    Impacted products
    Vendor Product Version
    medtronic guardian_link_2_transmitter_mmt-7730_firmware -
    medtronic guardian_link_2_transmitter_mmt-7730 -
    medtronic guardian_link_2_transmitter_mmt-7731_firmware -
    medtronic guardian_link_2_transmitter_mmt-7731 -
    medtronic guardian_link_2_transmitter_mmt-7738_firmware -
    medtronic guardian_link_2_transmitter_mmt-7738 -
    medtronic guardian_link_2_transmitter_mmt-7775_firmware -
    medtronic guardian_link_2_transmitter_mmt-7775 -
    medtronic guardian_link_3_transmitter_mmt-7810_firmware -
    medtronic guardian_link_3_transmitter_mmt-7810 -
    medtronic guardian_link_3_transmitter_mmt-7811_firmware -
    medtronic guardian_link_3_transmitter_mmt-7811 -
    medtronic minimed_620g_mmt-1750_firmware -
    medtronic minimed_620g_mmt-1750 -
    medtronic minimed_630g_mmt-1715_firmware -
    medtronic minimed_630g_mmt-1715 -
    medtronic minimed_630g_mmt-1754_firmware -
    medtronic minimed_630g_mmt-1754 -
    medtronic minimed_630g_mmt-1755_firmware -
    medtronic minimed_630g_mmt-1755 -
    medtronic minimed_640g_mmt-1711_firmware -
    medtronic minimed_640g_mmt-1711 -
    medtronic minimed_640g_mmt-1712_firmware -
    medtronic minimed_640g_mmt-1712 -
    medtronic minimed_640g_mmt-1751_firmware -
    medtronic minimed_640g_mmt-1751 -
    medtronic minimed_640g_mmt-1752_firmware -
    medtronic minimed_640g_mmt-1752 -
    medtronic minimed_670g_mmt-1740_firmware -
    medtronic minimed_670g_mmt-1740 -
    medtronic minimed_670g_mmt-1741_firmware -
    medtronic minimed_670g_mmt-1741 -
    medtronic minimed_670g_mmt-1742_firmware -
    medtronic minimed_670g_mmt-1742 -
    medtronic minimed_670g_mmt-1760_firmware -
    medtronic minimed_670g_mmt-1760 -
    medtronic minimed_670g_mmt-1761_firmware -
    medtronic minimed_670g_mmt-1761 -
    medtronic minimed_670g_mmt-1762_firmware -
    medtronic minimed_670g_mmt-1762 -
    medtronic minimed_670g_mmt-1780_firmware -
    medtronic minimed_670g_mmt-1780 -
    medtronic minimed_670g_mmt-1781_firmware -
    medtronic minimed_670g_mmt-1781 -
    medtronic minimed_670g_mmt-1782_firmware -
    medtronic minimed_670g_mmt-1782 -
    medtronic mmt-1151_firmware -
    medtronic mmt-1151 -
    medtronic mmt-1152_firmware -
    medtronic mmt-1152 -
    medtronic mmt-1351_firmware -
    medtronic mmt-1351 -
    medtronic mmt-1352_firmware -
    medtronic mmt-1352 -
    medtronic mmt-7306_firmware -
    medtronic mmt-7306 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Minimed 600 Series Insulin Pump",
              "vendor": "Medtronic",
              "versions": [
                {
                  "status": "affected",
                  "version": "620G, 630G, 640G, 670G"
                }
              ]
            }
          ],
          "source": "security@medtronic.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7730_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1C5AA07C-EB49-4DB1-91C5-5B7FF9BC60DE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7730:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "615FEF55-7051-4CE2-9D10-2D8643C8E599",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7731_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1E499AF-6392-4D48-A2AA-6DF89B725CF5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7731:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "60CD7CC1-83A0-4890-9C3D-80CFC435469A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7738_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D61D148-8A08-402B-8252-A0C7E2C1606D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7738:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A183442-FB5F-4BD0-A390-05E1D2BB9B9B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7775_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53B3B95A-1706-45A3-A70E-1B598F7E6E24",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7775:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8CB928B7-ABD2-40A7-9CBE-DA77A2FB3FC6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7810_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "795ADE03-3C93-48DB-B0C0-9D732A56619A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_3_transmitter_mmt-7810:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "209B1C70-6ABE-4AAE-B413-36BCED848C1E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7811_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "827E4A1F-E3A7-4BC1-8671-2E29A9690885",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:guardian_link_3_transmitter_mmt-7811:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A710ACB1-FB33-4410-ACB5-628BEF78B2DF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_620g_mmt-1750_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52100FBF-B15B-4C23-AF3E-D5B08A20138C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_620g_mmt-1750:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1C6E5125-613D-4318-8894-A0EA7E70A23A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1715_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D7A62CB9-0CB5-4E69-865B-6DCCC5E52623",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1715:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71B6DDBD-7710-48F0-AE17-666B0ABD85C7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1754_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD1DAC2D-E81E-4A9F-8EC3-475B68D08E4D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1754:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3AD50208-75AD-4201-B50B-9B3C2B92D4B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1755_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E7195EE-CFDC-4592-A40C-E4C809B3A299",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1755:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EFB1067F-85DD-4AC3-9A2D-96AF7487A169",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1711_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1DE3A51F-C0B9-4FE8-937F-3D0A65447B86",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1711:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "79D08E98-E921-48B6-860F-941AEAE6A1C6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1712_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D58A6AA9-E899-4EB0-B43A-5B55142037C9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1712:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "45D90195-01D6-40BC-B4CF-36FA555D1EC2",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1751_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB9F223A-63E6-4A62-B7D1-BA58547E8611",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1751:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "256F9F01-2109-4857-ABE5-3EA1284F8D93",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1752_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DF1C533C-43A1-407D-88DF-C9467D2B63E8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1752:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6685F923-556D-4274-99B4-6DB7A2FC75B8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1740_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22187A09-60DA-4359-B310-F9C982795EEF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1740:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E0000AE0-FD3F-4CC8-B00D-A1C58EE1BB1B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1741_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F8B6AAF-5043-48B7-A638-98F3624202ED",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1741:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "12584AA5-E57C-473A-8E1F-4398ADADFCD7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1742_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5AEA1F9-2259-44F7-B175-0C26ECDF228A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1742:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49C86FAB-7C0D-4F81-9CA2-2AF809760029",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1760_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF1A796D-25D0-4640-BF69-DE2886608F9B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1760:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F110C3E4-808E-4DF0-9952-E3C38EA36D66",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1761_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A4235875-59AE-42FB-B66C-03EDE76B12F0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1761:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A78FB8FF-C0C1-4678-B686-295ED7040659",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1762_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7BC3BEE-987F-4B65-9FE3-604FCB2487BC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1762:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "81B931BE-24E0-4D5F-866D-E715E4673474",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1780_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "665944D0-B221-4BC3-BE1B-0A6F77B4BCF1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1780:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9123F954-4788-417D-B06C-3EA8F9C08165",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1781_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52C27006-E33E-4025-B20A-60A2D9DB451B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1781:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48985412-63A5-4296-9EBD-7FBE617E5FC1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1782_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0BB979C-5A06-4975-83B7-D92A29E1FC03",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1782:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EEE3ED1A-6C7D-4D7F-A650-E905C8E92C2C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:mmt-1151_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9700FDA5-541C-48FF-A0FE-5B14B6B8A60A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:mmt-1151:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3056ECAE-8567-4704-ABEB-F07E2E16D50A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:mmt-1152_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5B8B0E02-BA08-4EBF-9D71-AD1B35252E5F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:mmt-1152:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5037978F-0204-4304-83BC-4201CCDCEB5C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:mmt-1351_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB0E24E7-9E50-4BA3-9F8A-4B44F84BF765",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:mmt-1351:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E08AC3AC-ED38-43FA-932E-93821076040D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:mmt-1352_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B54B7156-1903-4274-9743-9D69DF1D52D6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:mmt-1352:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08D75197-E41F-47BD-8079-38DB5659CF21",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:medtronic:mmt-7306_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0967A9CC-66FF-4C20-80BA-BEA5945EB793",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:medtronic:mmt-7306:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F3D5290-AC9A-4687-B634-CFF21FEB84FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance"
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad que podr\u00eda permitir que un usuario no autorizado conozca aspectos del protocolo de comunicaci\u00f3n utilizado para emparejar componentes del sistema mientras la bomba se empareja con otros componentes del sistema. La explotaci\u00f3n requiere proximidad de se\u00f1al inal\u00e1mbrica cercana con el paciente y el dispositivo; Se requieren conocimientos t\u00e9cnicos avanzados para su explotaci\u00f3n. Consulte el Bolet\u00edn de seguridad de productos de Medtronic para obtener orientaci\u00f3n."
        }
      ],
      "id": "CVE-2022-32537",
      "lastModified": "2026-06-17T04:47:29.910",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 3.6,
            "source": "security@medtronic.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-32537",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-29T14:44:04.441292Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-12-12T13:15:12.263",
      "references": [
        {
          "source": "security@medtronic.com",
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01"
        },
        {
          "source": "security@medtronic.com",
          "url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/minimed-600-series-communication-issue.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
        }
      ],
      "sourceIdentifier": "security@medtronic.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-693"
            }
          ],
          "source": "security@medtronic.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2022-32537 (GCVE-0-2022-32537)

    Vulnerability from nvd – Published: 2022-11-17 20:47 – Updated: 2026-05-07 14:30
    VLAI
    Title
    Medtronic MiniMed 600 Series Pump System Communication Issue
    Summary
    A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-29 14:44 UTC
    CWE
    Assigner
    Medtronic CNA under the icscert root
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Medtronic Minimed 600 Series Insulin Pump Affected: 620G, 630G, 640G, 670G
    Create a notification for this product.
    Date Public
    2022-09-20 19:31
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:46:43.499Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-32537",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-29T14:44:04.441292Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-29T14:44:21.348Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Minimed 600 Series Insulin Pump",
              "vendor": "Medtronic",
              "versions": [
                {
                  "status": "affected",
                  "version": "620G, 630G, 640G, 670G"
                }
              ]
            }
          ],
          "datePublic": "2022-09-20T19:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\u003cbr\u003e"
                }
              ],
              "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-07T14:30:25.630Z",
            "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
            "shortName": "Medtronic"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01"
            },
            {
              "url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/minimed-600-series-communication-issue.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Medtronic MiniMed 600 Series Pump System Communication Issue",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "assignerShortName": "Medtronic",
        "cveId": "CVE-2022-32537",
        "datePublished": "2022-11-17T20:47:05.258Z",
        "dateReserved": "2022-06-07T21:26:39.432Z",
        "dateUpdated": "2026-05-07T14:30:25.630Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-32537 (GCVE-0-2022-32537)

    Vulnerability from cvelistv5 – Published: 2022-11-17 20:47 – Updated: 2026-05-07 14:30
    VLAI
    Title
    Medtronic MiniMed 600 Series Pump System Communication Issue
    Summary
    A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-29 14:44 UTC
    CWE
    Assigner
    Medtronic CNA under the icscert root
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Medtronic Minimed 600 Series Insulin Pump Affected: 620G, 630G, 640G, 670G
    Create a notification for this product.
    Date Public
    2022-09-20 19:31
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:46:43.499Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-32537",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-29T14:44:04.441292Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-29T14:44:21.348Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Minimed 600 Series Insulin Pump",
              "vendor": "Medtronic",
              "versions": [
                {
                  "status": "affected",
                  "version": "620G, 630G, 640G, 670G"
                }
              ]
            }
          ],
          "datePublic": "2022-09-20T19:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\u003cbr\u003e"
                }
              ],
              "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-07T14:30:25.630Z",
            "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
            "shortName": "Medtronic"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01"
            },
            {
              "url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/minimed-600-series-communication-issue.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Medtronic MiniMed 600 Series Pump System Communication Issue",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "assignerShortName": "Medtronic",
        "cveId": "CVE-2022-32537",
        "datePublished": "2022-11-17T20:47:05.258Z",
        "dateReserved": "2022-06-07T21:26:39.432Z",
        "dateUpdated": "2026-05-07T14:30:25.630Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }