Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for mguard_delta_tx\/tx_vpn_firmware by phoenixcontact

    CVE-2018-5441 (GCVE-0-2018-5441)

    Vulnerability from nvd – Published: 2018-01-30 20:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a PHOENIX CONTACT mGuard Affected: PHOENIX CONTACT mGuard
    Date Public
    2018-01-30 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.317Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "102907",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/102907"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PHOENIX CONTACT mGuard",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "PHOENIX CONTACT mGuard"
                }
              ]
            }
          ],
          "datePublic": "2018-01-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-354",
                  "description": "CWE-354",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-16T13:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "102907",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/102907"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5441",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PHOENIX CONTACT mGuard",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "PHOENIX CONTACT mGuard"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-354"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "102907",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/102907"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
                },
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2018-001",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5441",
        "datePublished": "2018-01-30T20:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.317Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5441 (GCVE-0-2018-5441)

    Vulnerability from cvelistv5 – Published: 2018-01-30 20:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a PHOENIX CONTACT mGuard Affected: PHOENIX CONTACT mGuard
    Date Public
    2018-01-30 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.317Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "102907",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/102907"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PHOENIX CONTACT mGuard",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "PHOENIX CONTACT mGuard"
                }
              ]
            }
          ],
          "datePublic": "2018-01-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-354",
                  "description": "CWE-354",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-16T13:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "102907",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/102907"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5441",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PHOENIX CONTACT mGuard",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "PHOENIX CONTACT mGuard"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-354"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "102907",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/102907"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-030-01"
                },
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2018-001",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2018-001"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5441",
        "datePublished": "2018-01-30T20:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.317Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }