Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for melsec_iq-rj71pn92_firmware by mitsubishielectric

    FKIE_CVE-2020-5658

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:22
    Summary
    Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de errores de administraci\u00f3n de recursos en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a un atacante remoto no autenticado detener las funciones de red de los productos por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5658",
      "lastModified": "2026-06-17T03:22:03.230",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:34.103",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5657

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:22
    Summary
    Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Una neutralizaci\u00f3n inapropiada de los delimitadores de argumentos en una vulnerabilidad de comando (\"Argument Injection\") en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a los atacantes no autenticados en la red adyacente detener las funciones de red de los productos por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5657",
      "lastModified": "2026-06-17T03:22:03.110",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "ADJACENT_NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 3.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 6.5,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:34.023",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-88"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5656

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:22
    Summary
    Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de control de acceso inapropiado en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a un atacante remoto no autenticado detener las funciones de red de los productos o ejecutar un programa malicioso por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5656",
      "lastModified": "2026-06-17T03:22:02.413",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:33.960",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5655

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:21
    Summary
    NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de eliminaci\u00f3n de referencias de puntero NULL en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a un atacante remoto no autenticado detener las funciones de red de los productos por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5655",
      "lastModified": "2026-06-17T03:21:48.503",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:33.900",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5654

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:21
    Summary
    Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de fijaci\u00f3n de sesi\u00f3n en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a un atacante remoto no autenticado detener las funciones de red de los productos por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5654",
      "lastModified": "2026-06-17T03:21:47.623",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:33.837",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-384"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5653

    Vulnerability from fkie_nvd - Published: 2020-11-02 21:15 - Updated: 2026-06-17 03:21
    Summary
    Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71eip91_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9596438-7894-4689-BB8B-5FC2C26A1298",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71eip91:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "668C0031-6B41-487A-958C-E2C8A04E902B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rj71pn92_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F81F4A0C-68C9-474F-A695-CC7A2CB234D4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rj71pn92:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82DE76F0-810F-460A-933B-41E341125A9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81dl96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EDBB7DF2-C0D9-4F19-966A-C1EFF42BE6D2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81dl96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EC1B4D6-10A5-4DDE-BCF3-01CAE5389232",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81mes96n_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7285B9D4-9913-4421-9B47-DA4E9E7C6371",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81mes96n:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F76CBB13-1949-4941-A985-CB75D0109E47",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-rd81opc96_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14A32E47-C23B-4D2C-9B7E-1C080B1D7011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-rd81opc96:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48B179ED-8ACC-45EB-92A8-476A4F9F98E4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer en la funci\u00f3n TCP/IP incluida en el firmware de la serie MELSEC iQ-R (los 2 d\u00edgitos del n\u00famero de serie son \"02\" o anteriores del EtherNet/IP Network Interface Module First RJ71EIP91, los 2 d\u00edgitos del n\u00famero de serie es \"01\" o anteriores del PROFINET IO Controller Module First RJ71PN92, los 2 d\u00edgitos del n\u00famero de serie son \"08\" o anteriores del High Speed Data Logger Module First RD81DL96, los 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores del MES Interface Module First RD81MES96N, y los primeros de 2 d\u00edgitos del n\u00famero de serie son \"04\" o anteriores a OPC UA Server Module First RD81OPC96), permite a un atacante remoto no autenticado detener las funciones de red de los productos o ejecutar un programa malicioso por medio de un paquete especialmente dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-5653",
      "lastModified": "2026-06-17T03:21:45.983",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-02T21:15:33.757",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-120"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2020-5658 (GCVE-0-2020-5658)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Resource Management Errors
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Resource Management Errors",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:54.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5658",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Resource Management Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5658",
        "datePublished": "2020-10-30T03:35:54.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5657 (GCVE-0-2020-5657)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5657",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5657",
        "datePublished": "2020-10-30T03:35:54.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5656 (GCVE-0-2020-5656)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Fails to restrict access
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.477Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Fails to restrict access",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5656",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Fails to restrict access"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5656",
        "datePublished": "2020-10-30T03:35:53.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5655 (GCVE-0-2020-5655)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • NULL Pointer Dereference
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.490Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL Pointer Dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5655",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "NULL Pointer Dereference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5655",
        "datePublished": "2020-10-30T03:35:53.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.490Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5654 (GCVE-0-2020-5654)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Session fixation
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.640Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Session fixation",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:52.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5654",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Session fixation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5654",
        "datePublished": "2020-10-30T03:35:52.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.640Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5653 (GCVE-0-2020-5653)

    Vulnerability from nvd – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Buffer Overflow
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:52.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5653",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5653",
        "datePublished": "2020-10-30T03:35:52.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.391Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5658 (GCVE-0-2020-5658)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Resource Management Errors
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Resource Management Errors",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:54.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5658",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Resource Management Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5658",
        "datePublished": "2020-10-30T03:35:54.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5657 (GCVE-0-2020-5657)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5657",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5657",
        "datePublished": "2020-10-30T03:35:54.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5655 (GCVE-0-2020-5655)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • NULL Pointer Dereference
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.490Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL Pointer Dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5655",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "NULL Pointer Dereference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5655",
        "datePublished": "2020-10-30T03:35:53.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.490Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5656 (GCVE-0-2020-5656)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Fails to restrict access
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.477Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Fails to restrict access",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:53.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5656",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Fails to restrict access"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5656",
        "datePublished": "2020-10-30T03:35:53.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5654 (GCVE-0-2020-5654)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Session fixation
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.640Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Session fixation",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:52.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5654",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Session fixation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5654",
        "datePublished": "2020-10-30T03:35:52.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.640Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5653 (GCVE-0-2020-5653)

    Vulnerability from cvelistv5 – Published: 2020-10-30 03:35 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
    Severity
    No CVSS data available.
    CWE
    • Buffer Overflow
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 195 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Mitsubishi Electric Corporation MELSEC iQ-R series Affected: RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R series",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-30T03:35:52.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5653",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are \u002702\u0027 or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are \u002701\u0027 or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are \u002708\u0027 or before, RD81MES96N MES Interface Module First 2 digits of serial number are \u002704\u0027 or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are \u002704\u0027 or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-012.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-012_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU92513419/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU92513419/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5653",
        "datePublished": "2020-10-30T03:35:52.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.391Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }