    FKIE_CVE-2020-5594

    Vulnerability from fkie_nvd - Published: 2020-06-23 08:15 - Updated: 2026-06-17 03:21

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "source": "vultures@jpcert.or.jp"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F2A20BD-77FE-42A3-9AC6-597470CD1212",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71CC1A84-A51D-4E56-BA7A-9C1D21DDF8D1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1644AECC-4A04-4209-9654-668D6B3B093B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "175AA161-6775-4715-85A2-4AD426D131F5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-q_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1047B633-7FE4-47C2-846F-5878DA5D3038",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-q:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "418EA7F6-FB8D-4192-8BEC-E34BBF98400A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-l_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93701E98-1A2C-45EE-933F-2FA9D803A875",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FCADAD32-6840-45C7-94E1-DD7BE0A59417",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-fx_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "25DCC54F-CA89-41BC-8C3F-89084911956D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-fx:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "455C03F1-8A83-493D-9DAD-F7D0950105AF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
        },
        {
          "lang": "es",
          "value": "Todos los m\u00f3dulos de CPU de las series Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L y FX, contienen una vulnerabilidad que permite la transmisi\u00f3n de informaci\u00f3n confidencial entre m\u00f3dulos de CPU y GX Works3 y/o GX Works2 por medio de vectores no especificados"
        }
      ],
      "id": "CVE-2020-5594",
      "lastModified": "2026-06-17T03:21:39.730",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-23T08:15:10.487",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-319"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2020-5594 (GCVE-0-2020-5594)

    Vulnerability from nvd – Published: 2020-06-23 07:35 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Cleartext Transmission of Sensitive Information
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 194 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.558Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-06-23T07:35:23.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5594",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU91424496/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5594",
        "datePublished": "2020-06-23T07:35:23.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5594 (GCVE-0-2020-5594)

    Vulnerability from cvelistv5 – Published: 2020-06-23 07:35 – Updated: 2024-08-04 08:30
    VLAI
    Summary
    Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Cleartext Transmission of Sensitive Information
    Assigner
    jpcert CNA under the jpcert root
    CNA scorecard C 64/100 over 194 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:30:24.558Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-06-23T07:35:23.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2020-5594",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cleartext Transmission of Sensitive Information"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
                },
                {
                  "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU91424496/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2020-5594",
        "datePublished": "2020-06-23T07:35:23.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:30:24.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }