CVE-2020-15485 (GCVE-0-2020-15485)
Vulnerability from nvd – Published: 2020-08-26 19:12 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/lack-of-medical-data-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.661Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T19:12:37.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15485",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen",
"refsource": "MISC",
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15485",
"datePublished": "2020-08-26T19:12:38.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15483 (GCVE-0-2020-15483)
Vulnerability from nvd – Published: 2020-08-26 15:37 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/unauthenticated-uart-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.731Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T15:37:56.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15483",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15483",
"datePublished": "2020-08-26T15:37:56.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15482 (GCVE-0-2020-15482)
Vulnerability from nvd – Published: 2020-08-26 15:44 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/unauthenticated-telne… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.624Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T15:44:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15482",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15482",
"datePublished": "2020-08-26T15:44:14.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15484 (GCVE-0-2020-15484)
Vulnerability from nvd – Published: 2020-08-26 14:41 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/lack-of-medical-data-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.685Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T14:41:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15484",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15484",
"datePublished": "2020-08-26T14:41:06.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.685Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15485 (GCVE-0-2020-15485)
Vulnerability from cvelistv5 – Published: 2020-08-26 19:12 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/lack-of-medical-data-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.661Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T19:12:37.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15485",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen",
"refsource": "MISC",
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-dr-trust-ecg-or-ekg-pen"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15485",
"datePublished": "2020-08-26T19:12:38.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15482 (GCVE-0-2020-15482)
Vulnerability from cvelistv5 – Published: 2020-08-26 15:44 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/unauthenticated-telne… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.624Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T15:44:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15482",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/unauthenticated-telnet-service-in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15482",
"datePublished": "2020-08-26T15:44:14.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15483 (GCVE-0-2020-15483)
Vulnerability from cvelistv5 – Published: 2020-08-26 15:37 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/unauthenticated-uart-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.731Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T15:37:56.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15483",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/unauthenticated-uart-root-shell--in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15483",
"datePublished": "2020-08-26T15:37:56.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15484 (GCVE-0-2020-15484)
Vulnerability from cvelistv5 – Published: 2020-08-26 14:41 – Updated: 2024-08-04 13:15
VLAI
EPSS
VEX
Summary
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.niscomed.com/multipara-monitor.html | x_refsource_MISC |
| https://payatu.com/advisory/lack-of-medical-data-… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:15:20.685Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-26T14:41:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15484",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.niscomed.com/multipara-monitor.html",
"refsource": "MISC",
"url": "https://www.niscomed.com/multipara-monitor.html"
},
{
"name": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor",
"refsource": "MISC",
"url": "https://payatu.com/advisory/lack-of-medical-data-encryption-in-niscomed-patient-monitor"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15484",
"datePublished": "2020-08-26T14:41:06.000Z",
"dateReserved": "2020-07-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:15:20.685Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}