Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for ip7137_firmware by vivotek

    CVE-2025-66052 (GCVE-0-2025-66052)

    Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned
    VLAI
    Title
    Command injection in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66052",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T12:50:56.686031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T12:51:10.558Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:16.626Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66052",
        "datePublished": "2026-01-09T11:54:16.626Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T12:51:10.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66051 (GCVE-0-2025-66051)

    Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned
    VLAI
    Title
    Path traversal in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:22
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:06:46.935487Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:07:13.457Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:09.170Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Path traversal in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66051",
        "datePublished": "2026-01-09T11:54:09.170Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:07:13.457Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66050 (GCVE-0-2025-66050)

    Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned
    VLAI
    Title
    No password set for administrative account in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66050",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:07:49.180246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:08:08.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1393",
                  "description": "CWE-1393 Use of Default Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:45.338Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "No password set for administrative account in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66050",
        "datePublished": "2026-01-09T11:53:45.338Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:08:08.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66049 (GCVE-0-2025-66049)

    Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned
    VLAI
    Title
    Unprotected RTSP stream in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66049",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:22:03.331793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:22:19.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
                }
              ],
              "value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:41.060Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66049",
        "datePublished": "2026-01-09T11:53:41.060Z",
        "dateReserved": "2025-11-21T10:41:30.019Z",
        "dateUpdated": "2026-01-09T16:22:19.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66052 (GCVE-0-2025-66052)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned
    VLAI
    Title
    Command injection in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66052",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T12:50:56.686031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T12:51:10.558Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:16.626Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66052",
        "datePublished": "2026-01-09T11:54:16.626Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T12:51:10.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66051 (GCVE-0-2025-66051)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned
    VLAI
    Title
    Path traversal in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:22
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:06:46.935487Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:07:13.457Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:09.170Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Path traversal in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66051",
        "datePublished": "2026-01-09T11:54:09.170Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:07:13.457Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66050 (GCVE-0-2025-66050)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned
    VLAI
    Title
    No password set for administrative account in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66050",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:07:49.180246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:08:08.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1393",
                  "description": "CWE-1393 Use of Default Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:45.338Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "No password set for administrative account in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66050",
        "datePublished": "2026-01-09T11:53:45.338Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:08:08.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66049 (GCVE-0-2025-66049)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned
    VLAI
    Title
    Unprotected RTSP stream in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66049",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:22:03.331793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:22:19.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
                }
              ],
              "value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:41.060Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66049",
        "datePublished": "2026-01-09T11:53:41.060Z",
        "dateReserved": "2025-11-21T10:41:30.019Z",
        "dateUpdated": "2026-01-09T16:22:19.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }