Search criteria
8 vulnerabilities found for iot_gateway_software by bosch
CVE-2019-11603 (GCVE-0-2019-11603)
Vulnerability from nvd – Published: 2019-08-21 19:29 – Updated: 2024-09-16 23:46
VLAI?
Title
Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.027Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:29:23",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11603",
"STATE": "PUBLIC",
"TITLE": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11603",
"datePublished": "2019-08-21T19:29:23.032959Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-16T23:46:18.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11602 (GCVE-0-2019-11602)
Vulnerability from nvd – Published: 2019-08-21 19:21 – Updated: 2024-09-17 00:56
VLAI?
Title
Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure.
Severity ?
5.3 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:21:38",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11602",
"STATE": "PUBLIC",
"TITLE": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11602",
"datePublished": "2019-08-21T19:21:38.452272Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-17T00:56:40.970Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11601 (GCVE-0-2019-11601)
Vulnerability from nvd – Published: 2019-08-21 19:09 – Updated: 2024-09-16 17:59
VLAI?
Title
Path traversal in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A directory traversal vulnerability in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location.
Severity ?
9.1 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:09:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11601",
"STATE": "PUBLIC",
"TITLE": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11601",
"datePublished": "2019-08-21T19:09:01.029744Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-16T17:59:22.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11897 (GCVE-0-2019-11897)
Vulnerability from nvd – Published: 2019-08-21 17:09 – Updated: 2024-09-17 03:55
VLAI?
Title
Server-side request forgery in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server.
Severity ?
8.6 (High)
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | IoT Gateway Software |
Affected:
unspecified , < 9.3.0
(custom)
|
||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.663Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IoT Gateway Software",
"vendor": "Bosch",
"versions": [
{
"lessThan": "9.3.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "mBS SDK",
"vendor": "ProSyst",
"versions": [
{
"lessThan": "8.2.6",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T17:09:52",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11897",
"STATE": "PUBLIC",
"TITLE": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IoT Gateway Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.3.0"
}
]
}
}
]
},
"vendor_name": "Bosch"
},
{
"product": {
"product_data": [
{
"product_name": "mBS SDK",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "8.2.6"
}
]
}
}
]
},
"vendor_name": "ProSyst"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-918 Server-Side Request Forgery (SSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2019-11897",
"datePublished": "2019-08-21T17:09:52.545972Z",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-09-17T03:55:02.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11603 (GCVE-0-2019-11603)
Vulnerability from cvelistv5 – Published: 2019-08-21 19:29 – Updated: 2024-09-16 23:46
VLAI?
Title
Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.027Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:29:23",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11603",
"STATE": "PUBLIC",
"TITLE": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11603",
"datePublished": "2019-08-21T19:29:23.032959Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-16T23:46:18.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11602 (GCVE-0-2019-11602)
Vulnerability from cvelistv5 – Published: 2019-08-21 19:21 – Updated: 2024-09-17 00:56
VLAI?
Title
Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure.
Severity ?
5.3 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:21:38",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11602",
"STATE": "PUBLIC",
"TITLE": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11602",
"datePublished": "2019-08-21T19:21:38.452272Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-17T00:56:40.970Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11601 (GCVE-0-2019-11601)
Vulnerability from cvelistv5 – Published: 2019-08-21 19:09 – Updated: 2024-09-16 17:59
VLAI?
Title
Path traversal in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A directory traversal vulnerability in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location.
Severity ?
9.1 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:55:41.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:09:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11601",
"STATE": "PUBLIC",
"TITLE": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11601",
"datePublished": "2019-08-21T19:09:01.029744Z",
"dateReserved": "2019-04-30T00:00:00",
"dateUpdated": "2024-09-16T17:59:22.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11897 (GCVE-0-2019-11897)
Vulnerability from cvelistv5 – Published: 2019-08-21 17:09 – Updated: 2024-09-17 03:55
VLAI?
Title
Server-side request forgery in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
Summary
A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server.
Severity ?
8.6 (High)
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | IoT Gateway Software |
Affected:
unspecified , < 9.3.0
(custom)
|
||
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.663Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IoT Gateway Software",
"vendor": "Bosch",
"versions": [
{
"lessThan": "9.3.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "mBS SDK",
"vendor": "ProSyst",
"versions": [
{
"lessThan": "8.2.6",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T17:09:52",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11897",
"STATE": "PUBLIC",
"TITLE": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IoT Gateway Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.3.0"
}
]
}
}
]
},
"vendor_name": "Bosch"
},
{
"product": {
"product_data": [
{
"product_name": "mBS SDK",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "8.2.6"
}
]
}
}
]
},
"vendor_name": "ProSyst"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-918 Server-Side Request Forgery (SSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2019-11897",
"datePublished": "2019-08-21T17:09:52.545972Z",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-09-17T03:55:02.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}