Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for in.sight_b120\\37 by philips

    CVE-2015-2884 (GCVE-0-2015-2884)

    Vulnerability from nvd – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
    Severity
    No CVSS data available.
    CWE
    • DOA
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.301Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              },
              {
                "name": "97683",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97683"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "DOA",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-18T09:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            },
            {
              "name": "97683",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97683"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2884",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "DOA"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                },
                {
                  "name": "97683",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97683"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2884",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.301Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-2883 (GCVE-0-2015-2883)

    Vulnerability from nvd – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
    Severity
    No CVSS data available.
    CWE
    • XSS
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.208Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "XSS",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-10T02:57:02.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2883",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "XSS"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2883",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.208Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-2882 (GCVE-0-2015-2882)

    Vulnerability from nvd – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
    Severity
    No CVSS data available.
    CWE
    • backdoor
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.209Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "backdoor",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-10T02:57:02.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2882",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "backdoor"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2882",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.209Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-2882 (GCVE-0-2015-2882)

    Vulnerability from cvelistv5 – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
    Severity
    No CVSS data available.
    CWE
    • backdoor
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.209Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "backdoor",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-10T02:57:02.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2882",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "backdoor"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2882",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.209Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-2883 (GCVE-0-2015-2883)

    Vulnerability from cvelistv5 – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
    Severity
    No CVSS data available.
    CWE
    • XSS
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.208Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "XSS",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-10T02:57:02.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2883",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "XSS"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2883",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.208Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-2884 (GCVE-0-2015-2884)

    Vulnerability from cvelistv5 – Published: 2017-04-10 03:00 – Updated: 2024-08-06 05:32
    VLAI
    Summary
    Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
    Severity
    No CVSS data available.
    CWE
    • DOA
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Philips In.Sight B120/37 Affected: Philips In.Sight B120/37
    Date Public
    2017-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T05:32:20.301Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
              },
              {
                "name": "97683",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/97683"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Philips In.Sight B120/37",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Philips In.Sight B120/37"
                }
              ]
            }
          ],
          "datePublic": "2017-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "DOA",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-18T09:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
            },
            {
              "name": "97683",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/97683"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2015-2884",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Philips In.Sight B120/37",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Philips In.Sight B120/37"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "DOA"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors",
                  "refsource": "MISC",
                  "url": "https://community.rapid7.com/community/infosec/blog/2015/09/02/iotsec-disclosure-10-new-vulns-for-several-video-baby-monitors"
                },
                {
                  "name": "97683",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/97683"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2015-2884",
        "datePublished": "2017-04-10T03:00:00.000Z",
        "dateReserved": "2015-04-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T05:32:20.301Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }