Search criteria

6 vulnerabilities found for ib8367a_firmware by vivotek

CVE-2024-7443 (GCVE-0-2024-7443)

Vulnerability from nvd – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned
VLAI?
Title
Vivotek IB8367A upload_file.cgi getenv command injection
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
Assigner
References
https://vuldb.com/?id.273528 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273528 signaturepermissions-required
https://vuldb.com/?submit.383844 third-party-advisory
https://yjz233.notion.site/vivotek-IB8367A-has-co… broken-link
Impacted products
Vendor Product Version
Vivotek IB8367A Affected: VVTK-0100b
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ib8367a",
            "vendor": "vivotek",
            "versions": [
              {
                "status": "affected",
                "version": "vvtk-0100b"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7443",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T18:41:22.552464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:43:32.506Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IB8367A",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0100b"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T19:00:09.314Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273528"
        },
        {
          "name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273528"
        },
        {
          "name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383844"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek IB8367A upload_file.cgi getenv command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7443",
    "datePublished": "2024-08-03T19:00:09.314Z",
    "dateReserved": "2024-08-02T21:36:43.428Z",
    "dateUpdated": "2024-08-05T18:43:32.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11950 (GCVE-0-2020-11950)

Vulnerability from nvd – Published: 2020-05-28 12:44 – Updated: 2024-08-04 11:42
VLAI?
Summary
VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:42:00.764Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-05-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-28T12:44:36.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-11950",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf",
              "refsource": "CONFIRM",
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-11950",
    "datePublished": "2020-05-28T12:44:36.000Z",
    "dateReserved": "2020-04-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:42:00.764Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11949 (GCVE-0-2020-11949)

Vulnerability from nvd – Published: 2020-05-28 12:43 – Updated: 2024-08-04 11:42
VLAI?
Summary
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:42:00.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-05-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera\u0027s local filesystem. For example, this affects IT9388-HT devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-28T12:43:32.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-11949",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera\u0027s local filesystem. For example, this affects IT9388-HT devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf",
              "refsource": "CONFIRM",
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-11949",
    "datePublished": "2020-05-28T12:43:32.000Z",
    "dateReserved": "2020-04-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:42:00.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7443 (GCVE-0-2024-7443)

Vulnerability from cvelistv5 – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned
VLAI?
Title
Vivotek IB8367A upload_file.cgi getenv command injection
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
CWE
Assigner
References
https://vuldb.com/?id.273528 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273528 signaturepermissions-required
https://vuldb.com/?submit.383844 third-party-advisory
https://yjz233.notion.site/vivotek-IB8367A-has-co… broken-link
Impacted products
Vendor Product Version
Vivotek IB8367A Affected: VVTK-0100b
Create a notification for this product.
Credits
jylsec (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ib8367a",
            "vendor": "vivotek",
            "versions": [
              {
                "status": "affected",
                "version": "vvtk-0100b"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7443",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T18:41:22.552464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:43:32.506Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IB8367A",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0100b"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T19:00:09.314Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273528"
        },
        {
          "name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273528"
        },
        {
          "name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383844"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek IB8367A upload_file.cgi getenv command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7443",
    "datePublished": "2024-08-03T19:00:09.314Z",
    "dateReserved": "2024-08-02T21:36:43.428Z",
    "dateUpdated": "2024-08-05T18:43:32.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11950 (GCVE-0-2020-11950)

Vulnerability from cvelistv5 – Published: 2020-05-28 12:44 – Updated: 2024-08-04 11:42
VLAI?
Summary
VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:42:00.764Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-05-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-28T12:44:36.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-11950",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf",
              "refsource": "CONFIRM",
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-11950",
    "datePublished": "2020-05-28T12:44:36.000Z",
    "dateReserved": "2020-04-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:42:00.764Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11949 (GCVE-0-2020-11949)

Vulnerability from cvelistv5 – Published: 2020-05-28 12:43 – Updated: 2024-08-04 11:42
VLAI?
Summary
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:42:00.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-05-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera\u0027s local filesystem. For example, this affects IT9388-HT devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-28T12:43:32.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-11949",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera\u0027s local filesystem. For example, this affects IT9388-HT devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf",
              "refsource": "CONFIRM",
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2020-001-v1.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-11949",
    "datePublished": "2020-05-28T12:43:32.000Z",
    "dateReserved": "2020-04-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:42:00.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}