Search criteria
24 vulnerabilities found for iManager by NetIQ
CVE-2022-38758 (GCVE-0-2022-38758)
Vulnerability from nvd – Published: 2023-01-25 00:00 – Updated: 2025-03-27 20:15
VLAI?
Title
XSS vulnerabilities in iManager
Summary
Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user's browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL.
Severity ?
7.2 (High)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Micro Focus | NetIQ iManager |
Affected:
NetIQ iManager , < 3.2.6
(custom)
|
Credits
Special thanks to Kajetan Rostojek for responsibly disclosing this information to us.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:02:14.473Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38758",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T20:15:16.517246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T20:15:28.363Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"platforms": [
"ALL"
],
"product": "NetIQ iManager",
"vendor": "Micro Focus",
"versions": [
{
"lessThan": "3.2.6",
"status": "affected",
"version": "NetIQ iManager",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Special thanks to Kajetan Rostojek for responsibly disclosing this information to us."
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user\u0027s browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-25T00:00:00.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"url": "https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "XSS vulnerabilities in iManager",
"workarounds": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.2.6 or higher."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2022-38758",
"datePublished": "2023-01-25T00:00:00.000Z",
"dateReserved": "2022-08-25T00:00:00.000Z",
"dateUpdated": "2025-03-27T20:15:28.363Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-12462 (GCVE-0-2018-12462)
Vulnerability from nvd – Published: 2018-07-10 19:00 – Updated: 2024-09-16 18:56
VLAI?
Title
NetIQ iManager XSS vulnerabilities
Summary
NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.
Severity ?
4.8 (Medium)
CWE
- NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:38:06.153Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1.1",
"status": "affected",
"version": "NetIQ iManager",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-07-02T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:36",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1.1"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NetIQ iManager XSS vulnerabilities",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"DATE_PUBLIC": "2018-07-02T05:00:00.000Z",
"ID": "CVE-2018-12462",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager XSS vulnerabilities"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "NetIQ iManager",
"version_value": "3.1.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1.1"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-12462",
"datePublished": "2018-07-10T19:00:00Z",
"dateReserved": "2018-06-15T00:00:00",
"dateUpdated": "2024-09-16T18:56:13.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1347 (GCVE-0-2018-1347)
Vulnerability from nvd – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
NetIQ iManager, versions prior to 3.1, reflected XSS issue
Summary
The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting.
Severity ?
5.3 (Medium)
CWE
- Reflected XSS
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.588Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103492"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "iManager prior to (3.1)",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Reflected XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:24",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103492"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "NetIQ iManager, versions prior to 3.1, reflected XSS issue ",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1347",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager, versions prior to 3.1, reflected XSS issue "
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "iManager prior to (3.1)",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Reflected XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103492"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1347",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.588Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1345 (GCVE-0-2018-1345)
Vulnerability from nvd – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
iManager elevation of privilege
Summary
NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack.
Severity ?
5.9 (Medium)
CWE
- Elevation of Privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.253Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "prior to version 3.1",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:58",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "iManager elevation of privilege",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1345",
"STATE": "PUBLIC",
"TITLE": "iManager elevation of privilege"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "prior to version 3.1",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1345",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1344 (GCVE-0-2018-1344)
Vulnerability from nvd – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
NetIQ iManager Communication Downgrade Attack
Summary
Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1
Severity ?
CWE
- communication downgrade
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "iManager versions prior to 3.1",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "communication downgrade",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:59",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "NetIQ iManager Communication Downgrade Attack",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1344",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager Communication Downgrade Attack"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "iManager versions prior to 3.1",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "communication downgrade"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1344",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-5189 (GCVE-0-2017-5189)
Vulnerability from nvd – Published: 2018-03-02 20:00 – Updated: 2024-09-17 03:59
VLAI?
Title
private SSL key embedded in JAR file in iManager
Summary
NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance.
Severity ?
4.3 (Medium)
CWE
- Exposure of secret credentials in user exposed data
- CWE-522
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:55:35.377Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.0.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2017-04-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of secret credentials in user exposed data",
"lang": "en",
"type": "text"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:44",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
],
"source": {
"defect": [
"1021637"
],
"discovery": "UNKNOWN"
},
"title": "private SSL key embedded in JAR file in iManager",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"DATE_PUBLIC": "2017-04-01T00:00:00.000Z",
"ID": "CVE-2017-5189",
"STATE": "PUBLIC",
"TITLE": "private SSL key embedded in JAR file in iManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "3.0.3"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of secret credentials in user exposed data"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-522"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.suse.com/show_bug.cgi?id=1021637",
"refsource": "CONFIRM",
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
]
},
"source": {
"defect": [
"1021637"
],
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-5189",
"datePublished": "2018-03-02T20:00:00Z",
"dateReserved": "2017-01-06T00:00:00",
"dateUpdated": "2024-09-17T03:59:02.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7425 (GCVE-0-2017-7425)
Vulnerability from nvd – Published: 2017-11-06 17:00 – Updated: 2024-08-05 16:04
VLAI?
Title
Multiple Reflected XSS in iManager
Summary
Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2.
Severity ?
7.6 (High)
CWE
- XSS
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NetIQ Corporation | NetIQ iManager |
Affected:
2.7.7 Patch 10 HF2
Affected: 3.0.3.2 |
Credits
Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process..
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ iManager",
"vendor": "NetIQ Corporation",
"versions": [
{
"status": "affected",
"version": "2.7.7 Patch 10 HF2"
},
{
"status": "affected",
"version": "3.0.3.2"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:49",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "Multiple Reflected XSS in iManager",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7425",
"STATE": "PUBLIC",
"TITLE": "Multiple Reflected XSS in iManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ iManager",
"version": {
"version_data": [
{
"version_value": "2.7.7 Patch 10 HF2"
},
{
"version_value": "3.0.3.2"
}
]
}
}
]
},
"vendor_name": "NetIQ Corporation"
}
]
}
},
"credit": [
"Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7021423",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"name": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
]
},
"solution": "See 2.7.7.10 release notes located here: https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html \nSee 3.0.3.2 release notes located here: https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7425",
"datePublished": "2017-11-06T17:00:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7432 (GCVE-0-2017-7432)
Vulnerability from nvd – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability.
Severity ?
No CVSS data available.
CWE
- webshell upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "webshell upload",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:37",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7432",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "webshell upload"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1027619",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7432",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7431 (GCVE-0-2017-7431)
Vulnerability from nvd – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management.
Severity ?
No CVSS data available.
CWE
- CSRF
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CSRF",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:27",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7431",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CSRF"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1024963",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1030692",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7431",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7430 (GCVE-0-2017-7430)
Vulnerability from nvd – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework.
Severity ?
No CVSS data available.
CWE
- XSS
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.272Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:35",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@suse.com",
"ID": "CVE-2017-7430",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1024959",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1030691",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7430",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.272Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7428 (GCVE-0-2017-7428)
Vulnerability from nvd – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat.
Severity ?
No CVSS data available.
CWE
- renegotiation
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | NetIQ iManager 3.x before 3.0.3.1 |
Affected:
NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.728Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "renegotiation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:35",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@suse.com",
"ID": "CVE-2017-7428",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "renegotiation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1029431",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7428",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-5186 (GCVE-0-2017-5186)
Vulnerability from nvd – Published: 2017-04-27 14:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate.
Severity ?
No CVSS data available.
CWE
- deprecated hashing algorithm
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | NetIQ/Novell iManager and eDirectory |
Affected:
NetIQ/Novell iManager and eDirectory
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:55:35.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ/Novell iManager and eDirectory",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "NetIQ/Novell iManager and eDirectory"
}
]
}
],
"datePublic": "2017-04-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "deprecated hashing algorithm",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:59",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-5186",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ/Novell iManager and eDirectory",
"version": {
"version_data": [
{
"version_value": "NetIQ/Novell iManager and eDirectory"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "deprecated hashing algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016794",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=3426981",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1019789",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=988749",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1019041",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-5186",
"datePublished": "2017-04-27T14:00:00",
"dateReserved": "2017-01-06T00:00:00",
"dateUpdated": "2024-08-05T14:55:35.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38758 (GCVE-0-2022-38758)
Vulnerability from cvelistv5 – Published: 2023-01-25 00:00 – Updated: 2025-03-27 20:15
VLAI?
Title
XSS vulnerabilities in iManager
Summary
Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user's browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL.
Severity ?
7.2 (High)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Micro Focus | NetIQ iManager |
Affected:
NetIQ iManager , < 3.2.6
(custom)
|
Credits
Special thanks to Kajetan Rostojek for responsibly disclosing this information to us.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:02:14.473Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38758",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T20:15:16.517246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T20:15:28.363Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"platforms": [
"ALL"
],
"product": "NetIQ iManager",
"vendor": "Micro Focus",
"versions": [
{
"lessThan": "3.2.6",
"status": "affected",
"version": "NetIQ iManager",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Special thanks to Kajetan Rostojek for responsibly disclosing this information to us."
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user\u0027s browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-25T00:00:00.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"url": "https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "XSS vulnerabilities in iManager",
"workarounds": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.2.6 or higher."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2022-38758",
"datePublished": "2023-01-25T00:00:00.000Z",
"dateReserved": "2022-08-25T00:00:00.000Z",
"dateUpdated": "2025-03-27T20:15:28.363Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-12462 (GCVE-0-2018-12462)
Vulnerability from cvelistv5 – Published: 2018-07-10 19:00 – Updated: 2024-09-16 18:56
VLAI?
Title
NetIQ iManager XSS vulnerabilities
Summary
NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.
Severity ?
4.8 (Medium)
CWE
- NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:38:06.153Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1.1",
"status": "affected",
"version": "NetIQ iManager",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-07-02T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:36",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1.1"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NetIQ iManager XSS vulnerabilities",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"DATE_PUBLIC": "2018-07-02T05:00:00.000Z",
"ID": "CVE-2018-12462",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager XSS vulnerabilities"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "NetIQ iManager",
"version_value": "3.1.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "NetIQ iManager 3.1.1 addresses potential XSS vulnerabilities."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://support.microfocus.com/kb/doc.php?id=7016795"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1.1"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-12462",
"datePublished": "2018-07-10T19:00:00Z",
"dateReserved": "2018-06-15T00:00:00",
"dateUpdated": "2024-09-16T18:56:13.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1344 (GCVE-0-2018-1344)
Vulnerability from cvelistv5 – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
NetIQ iManager Communication Downgrade Attack
Summary
Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1
Severity ?
CWE
- communication downgrade
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "iManager versions prior to 3.1",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "communication downgrade",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:59",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "NetIQ iManager Communication Downgrade Attack",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1344",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager Communication Downgrade Attack"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "iManager versions prior to 3.1",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Addresses potential communication downgrade attack in NetIQ iManager versions prior to 3.1"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "communication downgrade"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1344",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1345 (GCVE-0-2018-1345)
Vulnerability from cvelistv5 – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
iManager elevation of privilege
Summary
NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack.
Severity ?
5.9 (Medium)
CWE
- Elevation of Privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.253Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "prior to version 3.1",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:58",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "iManager elevation of privilege",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1345",
"STATE": "PUBLIC",
"TITLE": "iManager elevation of privilege"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "prior to version 3.1",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager, versions prior to 3.1, under some circumstances could be susceptible to an elevation of privilege attack."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to NetIQ iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1345",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1347 (GCVE-0-2018-1347)
Vulnerability from cvelistv5 – Published: 2018-03-21 14:00 – Updated: 2024-08-05 03:59
VLAI?
Title
NetIQ iManager, versions prior to 3.1, reflected XSS issue
Summary
The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting.
Severity ?
5.3 (Medium)
CWE
- Reflected XSS
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:59:38.588Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103492"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.1",
"status": "affected",
"version": "iManager prior to (3.1)",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-02-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Reflected XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:24",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103492"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "NetIQ iManager, versions prior to 3.1, reflected XSS issue ",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-1347",
"STATE": "PUBLIC",
"TITLE": "NetIQ iManager, versions prior to 3.1, reflected XSS issue "
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "iManager prior to (3.1)",
"version_value": "3.1"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The administrative web interface in NetIQ iManager, versions prior to 3.1, are vulnerable to reflected cross site scripting."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Reflected XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-31/imanager31_releasenotes/data/imanager31_releasenotes.html"
},
{
"name": "103492",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103492"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to iManager 3.1"
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-1347",
"datePublished": "2018-03-21T14:00:00",
"dateReserved": "2017-12-10T00:00:00",
"dateUpdated": "2024-08-05T03:59:38.588Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-5189 (GCVE-0-2017-5189)
Vulnerability from cvelistv5 – Published: 2018-03-02 20:00 – Updated: 2024-09-17 03:59
VLAI?
Title
private SSL key embedded in JAR file in iManager
Summary
NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance.
Severity ?
4.3 (Medium)
CWE
- Exposure of secret credentials in user exposed data
- CWE-522
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:55:35.377Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iManager",
"vendor": "NetIQ",
"versions": [
{
"lessThan": "3.0.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2017-04-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of secret credentials in user exposed data",
"lang": "en",
"type": "text"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:44",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
],
"source": {
"defect": [
"1021637"
],
"discovery": "UNKNOWN"
},
"title": "private SSL key embedded in JAR file in iManager",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"DATE_PUBLIC": "2017-04-01T00:00:00.000Z",
"ID": "CVE-2017-5189",
"STATE": "PUBLIC",
"TITLE": "private SSL key embedded in JAR file in iManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iManager",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "3.0.3"
}
]
}
}
]
},
"vendor_name": "NetIQ"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of secret credentials in user exposed data"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-522"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.suse.com/show_bug.cgi?id=1021637",
"refsource": "CONFIRM",
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1021637"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
}
]
},
"source": {
"defect": [
"1021637"
],
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-5189",
"datePublished": "2018-03-02T20:00:00Z",
"dateReserved": "2017-01-06T00:00:00",
"dateUpdated": "2024-09-17T03:59:02.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7425 (GCVE-0-2017-7425)
Vulnerability from cvelistv5 – Published: 2017-11-06 17:00 – Updated: 2024-08-05 16:04
VLAI?
Title
Multiple Reflected XSS in iManager
Summary
Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2.
Severity ?
7.6 (High)
CWE
- XSS
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NetIQ Corporation | NetIQ iManager |
Affected:
2.7.7 Patch 10 HF2
Affected: 3.0.3.2 |
Credits
Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process..
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ iManager",
"vendor": "NetIQ Corporation",
"versions": [
{
"status": "affected",
"version": "2.7.7 Patch 10 HF2"
},
{
"status": "affected",
"version": "3.0.3.2"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:49",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "Multiple Reflected XSS in iManager",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7425",
"STATE": "PUBLIC",
"TITLE": "Multiple Reflected XSS in iManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ iManager",
"version": {
"version_data": [
{
"version_value": "2.7.7 Patch 10 HF2"
},
{
"version_value": "3.0.3.2"
}
]
}
}
]
},
"vendor_name": "NetIQ Corporation"
}
]
}
},
"credit": [
"Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7021423",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"name": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
]
},
"solution": "See 2.7.7.10 release notes located here: https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html \nSee 3.0.3.2 release notes located here: https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7425",
"datePublished": "2017-11-06T17:00:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7430 (GCVE-0-2017-7430)
Vulnerability from cvelistv5 – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework.
Severity ?
No CVSS data available.
CWE
- XSS
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.272Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:35",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@suse.com",
"ID": "CVE-2017-7430",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a persistent XSS vulnerability in Framework."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1024959",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024959"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1030691",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030691"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7430",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.272Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7431 (GCVE-0-2017-7431)
Vulnerability from cvelistv5 – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management.
Severity ?
No CVSS data available.
CWE
- CSRF
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CSRF",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:27",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7431",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have persistent CSRF in object management."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CSRF"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1024963",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1024963"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1030692",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1030692"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7431",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7428 (GCVE-0-2017-7428)
Vulnerability from cvelistv5 – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat.
Severity ?
No CVSS data available.
CWE
- renegotiation
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | NetIQ iManager 3.x before 3.0.3.1 |
Affected:
NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.728Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "renegotiation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:35",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@suse.com",
"ID": "CVE-2017-7428",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetIQ iManager 3.x before 3.0.3.1 has an issue in the renegotiation of connection parameters with Tomcat."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "renegotiation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1029431",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1029431"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7428",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7432 (GCVE-0-2017-7432)
Vulnerability from cvelistv5 – Published: 2017-05-03 05:13 – Updated: 2024-08-05 16:04
VLAI?
Summary
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability.
Severity ?
No CVSS data available.
CWE
- webshell upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 |
Affected:
Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
],
"datePublic": "2017-05-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "webshell upload",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:37",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7432",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1",
"version": {
"version_data": [
{
"version_value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7.x before 2.7 SP7 Patch 10 HF1 and NetIQ iManager 3.x before 3.0.3.1 have a webshell upload vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "webshell upload"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1027619",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1027619"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=24FxpmqdThE~"
},
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~",
"refsource": "CONFIRM",
"url": "https://dl.netiq.com/Download?buildid=wpS1UqIlx-o~"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7432",
"datePublished": "2017-05-03T05:13:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-5186 (GCVE-0-2017-5186)
Vulnerability from cvelistv5 – Published: 2017-04-27 14:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate.
Severity ?
No CVSS data available.
CWE
- deprecated hashing algorithm
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | NetIQ/Novell iManager and eDirectory |
Affected:
NetIQ/Novell iManager and eDirectory
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:55:35.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ/Novell iManager and eDirectory",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "NetIQ/Novell iManager and eDirectory"
}
]
}
],
"datePublic": "2017-04-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "deprecated hashing algorithm",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:59",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-5186",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ/Novell iManager and eDirectory",
"version": {
"version_data": [
{
"version_value": "NetIQ/Novell iManager and eDirectory"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "deprecated hashing algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016794",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016794"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=3426981",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=3426981"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1019789",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019789"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=988749",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=988749"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7010166",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7010166"
},
{
"name": "https://bugzilla.novell.com/show_bug.cgi?id=1019041",
"refsource": "CONFIRM",
"url": "https://bugzilla.novell.com/show_bug.cgi?id=1019041"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-5186",
"datePublished": "2017-04-27T14:00:00",
"dateReserved": "2017-01-06T00:00:00",
"dateUpdated": "2024-08-05T14:55:35.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}