Search criteria
14 vulnerabilities found for i9 by Tenda
VAR-202209-1750
Vulnerability from variot - Updated: 2025-05-23 23:28Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDset function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1750",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"cve": "CVE-2022-40102",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14300",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40102",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40102",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40102",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40102",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40102",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14300",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2429",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDset function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40102"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "CNVD",
"id": "CNVD-2023-14300"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40102",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14300",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"id": "VAR-202209-1750",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
}
]
},
"last_update_date": "2025-05-23T23:28:15.168000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 formwrlSSIDset function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412466"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209271"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formwrlssidset.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40102"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40102/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"date": "2022-09-23T19:15:14.823000",
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14300"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017752"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2429"
},
{
"date": "2025-05-22T18:15:25.047000",
"db": "NVD",
"id": "CVE-2022-40102"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017752"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2429"
}
],
"trust": 0.6
}
}
VAR-202209-1829
Vulnerability from variot - Updated: 2025-05-23 23:19Tenda i9 v1.0.0.8(3828) was discovered to contain a command injection vulnerability via the FormexeCommand function. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1829",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"cve": "CVE-2022-40100",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40100",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-40100",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40100",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40100",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-40100",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2431",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a command injection vulnerability via the FormexeCommand function. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40100"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40100",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017754",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2431",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"id": "VAR-202209-1829",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.6166667
},
"last_update_date": "2025-05-23T23:19:57.715000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda i9 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209273"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/command_injection_formexecommand.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40100"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40100/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"date": "2022-09-23T19:15:14.733000",
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017754"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2431"
},
{
"date": "2025-05-22T18:15:24.667000",
"db": "NVD",
"id": "CVE-2022-40100"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Command injection vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017754"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2431"
}
],
"trust": 0.6
}
}
VAR-202209-1828
Vulnerability from variot - Updated: 2025-05-23 23:19Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDget function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1828",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"cve": "CVE-2022-40104",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14302",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40104",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40104",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40104",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40104",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40104",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14302",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2440",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDget function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40104"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "CNVD",
"id": "CNVD-2023-14302"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40104",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14302",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"id": "VAR-202209-1828",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
}
]
},
"last_update_date": "2025-05-23T23:19:10.194000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 formwrlSSIDgett function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412456"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209274"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formwrlssidget.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40104"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40104/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"date": "2022-09-23T19:15:14.907000",
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14302"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017750"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2440"
},
{
"date": "2025-05-22T19:15:34.760000",
"db": "NVD",
"id": "CVE-2022-40104"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017750"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2440"
}
],
"trust": 0.6
}
}
VAR-202209-1665
Vulnerability from variot - Updated: 2025-05-23 23:15Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1665",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"cve": "CVE-2022-40101",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14299",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40101",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40101",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40101",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40101",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40101",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14299",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2430",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40101"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "CNVD",
"id": "CNVD-2023-14299"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40101",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14299",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"id": "VAR-202209-1665",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
}
]
},
"last_update_date": "2025-05-23T23:15:52.777000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 formWifiMacFilterSet function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412471"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209272"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formwifimacfilterset.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40101"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40101/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"date": "2022-09-23T19:15:14.780000",
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14299"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017753"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2430"
},
{
"date": "2025-05-22T18:15:24.860000",
"db": "NVD",
"id": "CVE-2022-40101"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017753"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2430"
}
],
"trust": 0.6
}
}
VAR-202209-1792
Vulnerability from variot - Updated: 2025-05-23 23:13Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterGet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1792",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"cve": "CVE-2022-40105",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14303",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40105",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40105",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40105",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40105",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40105",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14303",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2427",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterGet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40105"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "CNVD",
"id": "CNVD-2023-14303"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40105",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14303",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2427",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"id": "VAR-202209-1792",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
}
]
},
"last_update_date": "2025-05-23T23:13:25.470000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209269"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formwifimacfilterget.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40105"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40106"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40105/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"date": "2022-09-23T19:15:14.950000",
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017749"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2427"
},
{
"date": "2025-05-22T19:15:34.973000",
"db": "NVD",
"id": "CVE-2022-40105"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017749"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2427"
}
],
"trust": 0.6
}
}
VAR-202209-1619
Vulnerability from variot - Updated: 2025-05-23 23:08Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formSetAutoPing function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1619",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"cve": "CVE-2022-40103",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 4.9,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CNVD-2023-14301",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"id": "CVE-2022-40103",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 5.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40103",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40103",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40103",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-40103",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2023-14301",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2428",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formSetAutoPing function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40103"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "CNVD",
"id": "CNVD-2023-14301"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40103",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14301",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"id": "VAR-202209-1619",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
}
]
},
"last_update_date": "2025-05-23T23:08:22.837000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 formSetAutoPing function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412461"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209270"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formsetautoping.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40103"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40103/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"date": "2022-09-23T19:15:14.867000",
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14301"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017751"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2428"
},
{
"date": "2025-05-22T18:15:25.243000",
"db": "NVD",
"id": "CVE-2022-40103"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017751"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2428"
}
],
"trust": 0.6
}
}
VAR-202209-1752
Vulnerability from variot - Updated: 2025-05-22 23:10Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formexeCommand function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1752",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"cve": "CVE-2022-40107",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14305",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40107",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40107",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40107",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40107",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40107",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14305",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2424",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formexeCommand function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40107"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "CNVD",
"id": "CNVD-2023-14305"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40107",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14305",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"id": "VAR-202209-1752",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
}
]
},
"last_update_date": "2025-05-22T23:10:12.477000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 formexeCommand function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412446"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209267"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_formexecommand.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40107"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40107/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"date": "2022-09-23T19:15:15.040000",
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14305"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017747"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2424"
},
{
"date": "2025-05-22T15:15:59.780000",
"db": "NVD",
"id": "CVE-2022-40107"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017747"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2424"
}
],
"trust": 0.6
}
}
VAR-202209-1751
Vulnerability from variot - Updated: 2025-05-22 22:58Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the set_local_time function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-1751",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.2,
"vendor": "tenda",
"version": "v1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.8\\(3828\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"cve": "CVE-2022-40106",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14303",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-14304",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-40106",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-40106",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-40106",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-40106",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-40106",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-14303",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-14304",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-2426",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the set_local_time function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda i9 is an enterprise wireless AP device",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40106"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40106",
"trust": 4.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-14303",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2023-14304",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"id": "VAR-202209-1751",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
}
],
"trust": 1.8166666999999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 1.2
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
}
]
},
"last_update_date": "2025-05-22T22:58:52.289000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 set_local_time function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/412451"
},
{
"title": "Tenda i9 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=209268"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40106"
},
{
"trust": 1.6,
"url": "https://github.com/splashsc/iot_vulnerability_discovery/blob/main/tenda/tenda_i9/buffer_overflow_set_local_time.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40106/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"date": "2023-10-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"date": "2022-09-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"date": "2022-09-23T19:15:14.993000",
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14303"
},
{
"date": "2023-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-14304"
},
{
"date": "2023-10-16T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2022-017748"
},
{
"date": "2022-09-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-2426"
},
{
"date": "2025-05-22T16:15:53.297000",
"db": "NVD",
"id": "CVE-2022-40106"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-017748"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-2426"
}
],
"trust": 0.6
}
}
VAR-202411-1479
Vulnerability from variot - Updated: 2025-03-08 23:26A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i9 The firmware has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state. Tenda i9 is a ceiling-mounted wireless access point from China's Tenda company. An attacker can exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202411-1479",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.8(3828)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.0.8(3828)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
}
]
},
"cve": "CVE-2024-11650",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-11650",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 6.8,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-019933",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-48103",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2024-11650",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-019933",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-11650",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2024-019933",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-48103",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i9 The firmware has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state. Tenda i9 is a ceiling-mounted wireless access point from China\u0027s Tenda company. An attacker can exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-11650"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "CNVD",
"id": "CNVD-2024-48103"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-11650",
"trust": 3.2
},
{
"db": "VULDB",
"id": "285971",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-48103",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"id": "VAR-202411-1479",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
}
],
"trust": 1.2166667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
}
]
},
"last_update_date": "2025-03-08T23:26:05.947000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-404",
"trust": 1.0
},
{
"problemtype": "CWE-476",
"trust": 1.0
},
{
"problemtype": "Improper shutdown and release of resources (CWE-404) [ others ]",
"trust": 0.8
},
{
"problemtype": "NULL Pointer dereference (CWE-476) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": "NULL Pointer dereference (CWE-476) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/xiaobor123/tenda-vul-i9"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.446592"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-11650"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.285971"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.285971"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-12-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"date": "2025-03-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"date": "2024-11-25T03:15:06.707000",
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-12-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-48103"
},
{
"date": "2025-03-07T03:09:00",
"db": "JVNDB",
"id": "JVNDB-2024-019933"
},
{
"date": "2024-11-25T03:15:06.707000",
"db": "NVD",
"id": "CVE-2024-11650"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 in the firmware \u00a0NULL\u00a0 Pointer dereference vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-019933"
}
],
"trust": 0.8
}
}
VAR-202401-1084
Vulnerability from variot - Updated: 2024-08-14 15:41A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda i9 is a ceiling-mounted wireless access point from the Chinese company Tenda. This vulnerability is caused by the funcpara1 parameter of the formSetCfm function of /goform/setcfm failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or Lead to denial of service attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-1084",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.6\\(1020\\)"
},
{
"model": "i9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "i9 firmware 1.0.0.6(1020)"
},
{
"model": "i9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "i9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.0.9"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"cve": "CVE-2024-0996",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"id": "CVE-2024-0996",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"id": "CNVD-2024-09304",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2024-0996",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-0996",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-0996",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-0996",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-0996",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2024-0996",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-09304",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda i9 is a ceiling-mounted wireless access point from the Chinese company Tenda. This vulnerability is caused by the funcpara1 parameter of the formSetCfm function of /goform/setcfm failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or Lead to denial of service attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-0996"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "CNVD",
"id": "CNVD-2024-09304"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-0996",
"trust": 3.2
},
{
"db": "VULDB",
"id": "252261",
"trust": 1.6
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-09304",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"id": "VAR-202401-1084",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
}
],
"trust": 1.18967394
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
}
]
},
"last_update_date": "2024-08-14T15:41:25.583000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda i9 buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/525961"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://vuldb.com/?id.252261"
},
{
"trust": 1.0,
"url": "https://jylsec.notion.site/tenda-i9-has-stack-buffer-overflow-vulnerability-in-formsetcfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.252261"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-0996"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"date": "2024-02-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"date": "2024-01-29T03:15:07.217000",
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09304"
},
{
"date": "2024-02-07T03:06:00",
"db": "JVNDB",
"id": "JVNDB-2024-001957"
},
{
"date": "2024-05-17T02:35:08.277000",
"db": "NVD",
"id": "CVE-2024-0996"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i9\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001957"
}
],
"trust": 0.8
}
}
CVE-2024-11650 (GCVE-0-2024-11650)
Vulnerability from nvd – Published: 2024-11-25 02:00 – Updated: 2024-11-25 19:18| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:i9_firmware:1.0.0.8\\(3828\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.8 (3828)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11650",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T19:12:30.447804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T19:18:13.718Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "i9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.8(3828)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xiaobor123 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda i9 1.0.0.8(3828) gefunden. Es geht hierbei um die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Manipulation mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T02:00:15.883Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-285971 | Tenda i9 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.285971"
},
{
"name": "VDB-285971 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.285971"
},
{
"name": "Submit #446592 | Tenda i9 V1.0.0.8(3828) NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.446592"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiaobor123/tenda-vul-i9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-24T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-24T16:08:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i9 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11650",
"datePublished": "2024-11-25T02:00:15.883Z",
"dateReserved": "2024-11-24T15:03:41.995Z",
"dateUpdated": "2024-11-25T19:18:13.718Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0996 (GCVE-0-2024-0996)
Vulnerability from nvd – Published: 2024-01-29 02:31 – Updated: 2025-06-17 21:29- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252261"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252261"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0996",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-29T13:25:33.504123Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:17.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda i9 1.0.0.9(4122) entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch das Beeinflussen des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T02:31:04.436Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252261"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252261"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:45:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i9 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0996",
"datePublished": "2024-01-29T02:31:04.436Z",
"dateReserved": "2024-01-28T15:39:42.454Z",
"dateUpdated": "2025-06-17T21:29:17.187Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11650 (GCVE-0-2024-11650)
Vulnerability from cvelistv5 – Published: 2024-11-25 02:00 – Updated: 2024-11-25 19:18| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:i9_firmware:1.0.0.8\\(3828\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.8 (3828)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11650",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T19:12:30.447804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T19:18:13.718Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "i9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.8(3828)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xiaobor123 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda i9 1.0.0.8(3828) gefunden. Es geht hierbei um die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Manipulation mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T02:00:15.883Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-285971 | Tenda i9 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.285971"
},
{
"name": "VDB-285971 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.285971"
},
{
"name": "Submit #446592 | Tenda i9 V1.0.0.8(3828) NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.446592"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiaobor123/tenda-vul-i9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-24T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-24T16:08:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i9 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-11650",
"datePublished": "2024-11-25T02:00:15.883Z",
"dateReserved": "2024-11-24T15:03:41.995Z",
"dateUpdated": "2024-11-25T19:18:13.718Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0996 (GCVE-0-2024-0996)
Vulnerability from cvelistv5 – Published: 2024-01-29 02:31 – Updated: 2025-06-17 21:29- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252261"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252261"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0996",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-29T13:25:33.504123Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:17.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda i9 1.0.0.9(4122) entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch das Beeinflussen des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T02:31:04.436Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252261"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252261"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:45:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i9 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0996",
"datePublished": "2024-01-29T02:31:04.436Z",
"dateReserved": "2024-01-28T15:39:42.454Z",
"dateUpdated": "2025-06-17T21:29:17.187Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",