Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for husky_rtu_6049-e70_firmware by s3india

    CVE-2020-7802 (GCVE-0-2020-7802)

    Vulnerability from nvd – Published: 2020-04-14 16:40 – Updated: 2024-08-04 09:41
    VLAI
    Summary
    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:41:01.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-14T16:40:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-7802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-7802",
        "datePublished": "2020-04-14T16:40:07.000Z",
        "dateReserved": "2020-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:41:01.659Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20046 (GCVE-0-2019-20046)

    Vulnerability from nvd – Published: 2020-02-14 16:18 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.500Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-14T16:18:35.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-20046",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20046",
        "datePublished": "2020-02-14T16:18:35.000Z",
        "dateReserved": "2019-12-27T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.500Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20045 (GCVE-0-2019-20045)

    Vulnerability from nvd – Published: 2020-02-14 16:18 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.536Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-14T16:18:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-20045",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20045",
        "datePublished": "2020-02-14T16:18:38.000Z",
        "dateReserved": "2019-12-27T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.536Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7802 (GCVE-0-2020-7802)

    Vulnerability from cvelistv5 – Published: 2020-04-14 16:40 – Updated: 2024-08-04 09:41
    VLAI
    Summary
    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:41:01.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-14T16:40:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-7802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-7802",
        "datePublished": "2020-04-14T16:40:07.000Z",
        "dateReserved": "2020-01-22T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:41:01.659Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20045 (GCVE-0-2019-20045)

    Vulnerability from cvelistv5 – Published: 2020-02-14 16:18 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.536Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-14T16:18:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-20045",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20045",
        "datePublished": "2020-02-14T16:18:38.000Z",
        "dateReserved": "2019-12-27T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.536Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20046 (GCVE-0-2019-20046)

    Vulnerability from cvelistv5 – Published: 2020-02-14 16:18 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.500Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-14T16:18:35.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-20046",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Synergy Systems \u0026 Solutions PLC \u0026 RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20046",
        "datePublished": "2020-02-14T16:18:35.000Z",
        "dateReserved": "2019-12-27T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.500Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }