Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for homematic_central_control_unit_ccu2_firmware by eq-3

    CVE-2018-7301 (GCVE-0-2018-7301)

    Vulnerability from nvd – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.833Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7301",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7301",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7299 (GCVE-0-2018-7299)

    Vulnerability from nvd – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.891Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7299",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7299",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7298 (GCVE-0-2018-7298)

    Vulnerability from nvd – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.812Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7298",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7298",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7297 (GCVE-0-2018-7297)

    Vulnerability from nvd – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.828Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
              },
              {
                "name": "44368",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/44368/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-01T09:57:02.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
            },
            {
              "name": "44368",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/44368/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7297",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
                },
                {
                  "name": "44368",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/44368/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7297",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.828Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7296 (GCVE-0-2018-7296)

    Vulnerability from nvd – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.892Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2\u0027s filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7296",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2\u0027s filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-fileread",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7296",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.892Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7299 (GCVE-0-2018-7299)

    Vulnerability from cvelistv5 – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.891Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7299",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7299",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7298 (GCVE-0-2018-7298)

    Vulnerability from cvelistv5 – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.812Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7298",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-firmware-via-plain-http"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7298",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7296 (GCVE-0-2018-7296)

    Vulnerability from cvelistv5 – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.892Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2\u0027s filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7296",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2\u0027s filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-fileread",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-fileread"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7296",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.892Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7301 (GCVE-0-2018-7301)

    Vulnerability from cvelistv5 – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.833Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-02-22T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7301",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7301",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7297 (GCVE-0-2018-7297)

    Vulnerability from cvelistv5 – Published: 2018-02-22 19:00 – Updated: 2024-08-05 06:24
    VLAI
    Summary
    Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-02-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:24:11.828Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
              },
              {
                "name": "44368",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/44368/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-02-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-01T09:57:02.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
            },
            {
              "name": "44368",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/44368/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-7297",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution",
                  "refsource": "MISC",
                  "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution"
                },
                {
                  "name": "44368",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/44368/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-7297",
        "datePublished": "2018-02-22T19:00:00.000Z",
        "dateReserved": "2018-02-21T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:24:11.828Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }