    VAR-201806-0944

    Vulnerability from variot - Updated: 2024-11-23 22:45

    Cross-site scripting (XSS) vulnerability on Brother HL series printers allows remote attackers to inject arbitrary web script or HTML via the url parameter to etc/loginerror.html. Brother HL-L2340D and HL-L2380DW Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201806-0944",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "hl-l2340d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "brother",
            "version": "1.16"
          },
          {
            "model": "hl-l2380dw",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "brother",
            "version": "1.16"
          },
          {
            "model": "hl-l2340d",
            "scope": null,
            "trust": 0.8,
            "vendor": "brother industry",
            "version": null
          },
          {
            "model": "hl-l2380dw",
            "scope": null,
            "trust": 0.8,
            "vendor": "brother industry",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:brother:hl-l2340d_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:brother:hl-l2380dw_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          }
        ]
      },
      "cve": "CVE-2018-11581",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2018-11581",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2018-11581",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.8,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-11581",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-11581",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201806-123",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cross-site scripting (XSS) vulnerability on Brother HL series printers allows remote attackers to inject arbitrary web script or HTML via the url parameter to etc/loginerror.html. Brother HL-L2340D and HL-L2380DW Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-11581",
            "trust": 2.4
          },
          {
            "db": "EXPLOIT-DB",
            "id": "44839",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "id": "VAR-201806-0944",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 1.0
      },
      "last_update_date": "2024-11-23T22:45:18.018000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.brother-usa.com/"
          },
          {
            "title": "Brother HL-L2340D  and HL-L2380DW Fixes for Series Printer Cross-Site Scripting Vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=81319"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.exploit-db.com/exploits/44839/"
          },
          {
            "trust": 1.0,
            "url": "https://support.brother.com/g/b/faqend.aspx?c=us_ot\u0026lang=en\u0026prod=group2\u0026ftype3=100033\u0026faqid=faq00100530_000"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11581"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11581"
          },
          {
            "trust": 0.6,
            "url": "https://gist.github.com/huykha/409451e4b086bfbd55e28e7e803ae930"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "date": "2018-06-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "date": "2018-06-01T17:29:00.377000",
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          },
          {
            "date": "2018-06-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          },
          {
            "date": "2024-11-21T03:43:39.640000",
            "db": "NVD",
            "id": "CVE-2018-11581"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Brother HL-L2340D and  HL-L2380DW Vulnerable to cross-site scripting",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004549"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-123"
          }
        ],
        "trust": 0.6
      }
    }