Search criteria
14 vulnerabilities found for hg9_firmware by tenda
CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from nvd – Published: 2026-02-22 02:32 – Updated: 2026-02-23 19:17
VLAI?
Title
Tenda HG9 formPing6 stack-based overflow
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:17:14.139751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:17:27.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:32:11.075Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347219"
},
{
"name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347219"
},
{
"name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755212"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 formPing6 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2910",
"datePublished": "2026-02-22T02:32:11.075Z",
"dateReserved": "2026-02-20T20:14:51.686Z",
"dateUpdated": "2026-02-23T19:17:27.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from nvd – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:18
VLAI?
Title
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2909",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:18:27.278329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:18:40.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Diagnostic Ping Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:14.122Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347218"
},
{
"name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347218"
},
{
"name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755211"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2909",
"datePublished": "2026-02-22T02:02:14.122Z",
"dateReserved": "2026-02-20T20:14:48.904Z",
"dateUpdated": "2026-02-23T19:18:40.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from nvd – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:19
VLAI?
Title
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2908",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:19:17.915757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:19:51.049Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Loopback Detection Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:10.921Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347217"
},
{
"name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347217"
},
{
"name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755202"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2908",
"datePublished": "2026-02-22T02:02:10.921Z",
"dateReserved": "2026-02-20T20:14:45.983Z",
"dateUpdated": "2026-02-23T19:19:51.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from nvd – Published: 2026-02-22 01:32 – Updated: 2026-02-23 19:23
VLAI?
Title
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:22:46.303895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:23:03.755Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"GPON Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:12.542Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347216"
},
{
"name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347216"
},
{
"name": "Submit #755201 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755201"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2907",
"datePublished": "2026-02-22T01:32:12.542Z",
"dateReserved": "2026-02-20T20:14:43.142Z",
"dateUpdated": "2026-02-23T19:23:03.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from nvd – Published: 2026-02-22 01:32 – Updated: 2026-02-24 15:38
VLAI?
Title
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-24T15:38:13.838475Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T15:38:54.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Samba Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:09.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347215"
},
{
"name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347215"
},
{
"name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755193"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2906",
"datePublished": "2026-02-22T01:32:09.390Z",
"dateReserved": "2026-02-20T20:14:40.341Z",
"dateUpdated": "2026-02-24T15:38:54.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from nvd – Published: 2026-02-22 01:02 – Updated: 2026-02-23 19:13
VLAI?
Title
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2905",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:13:05.204806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:13:59.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:02:10.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347214"
},
{
"name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347214"
},
{
"name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755167"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2905",
"datePublished": "2026-02-22T01:02:10.433Z",
"dateReserved": "2026-02-20T20:14:32.380Z",
"dateUpdated": "2026-02-23T19:13:59.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-30023 (GCVE-0-2022-30023)
Vulnerability from nvd – Published: 2022-06-16 14:28 – Updated: 2024-08-03 06:40
VLAI?
Summary
Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.254Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://tenda.com"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ont.com"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-16T14:28:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://tenda.com"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ont.com"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-30023",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://tenda.com",
"refsource": "MISC",
"url": "http://tenda.com"
},
{
"name": "http://ont.com",
"refsource": "MISC",
"url": "http://ont.com"
},
{
"name": "https://github.com/Haniwa0x01/CVE-2022-30023",
"refsource": "MISC",
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-30023",
"datePublished": "2022-06-16T14:28:27",
"dateReserved": "2022-05-02T00:00:00",
"dateUpdated": "2024-08-03T06:40:47.254Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:32 – Updated: 2026-02-23 19:17
VLAI?
Title
Tenda HG9 formPing6 stack-based overflow
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:17:14.139751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:17:27.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:32:11.075Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347219"
},
{
"name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347219"
},
{
"name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755212"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 formPing6 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2910",
"datePublished": "2026-02-22T02:32:11.075Z",
"dateReserved": "2026-02-20T20:14:51.686Z",
"dateUpdated": "2026-02-23T19:17:27.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:18
VLAI?
Title
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2909",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:18:27.278329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:18:40.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Diagnostic Ping Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:14.122Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347218"
},
{
"name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347218"
},
{
"name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755211"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2909",
"datePublished": "2026-02-22T02:02:14.122Z",
"dateReserved": "2026-02-20T20:14:48.904Z",
"dateUpdated": "2026-02-23T19:18:40.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:19
VLAI?
Title
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2908",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:19:17.915757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:19:51.049Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Loopback Detection Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:10.921Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347217"
},
{
"name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347217"
},
{
"name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755202"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2908",
"datePublished": "2026-02-22T02:02:10.921Z",
"dateReserved": "2026-02-20T20:14:45.983Z",
"dateUpdated": "2026-02-23T19:19:51.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-23 19:23
VLAI?
Title
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:22:46.303895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:23:03.755Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"GPON Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:12.542Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347216"
},
{
"name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347216"
},
{
"name": "Submit #755201 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755201"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2907",
"datePublished": "2026-02-22T01:32:12.542Z",
"dateReserved": "2026-02-20T20:14:43.142Z",
"dateUpdated": "2026-02-23T19:23:03.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-24 15:38
VLAI?
Title
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-24T15:38:13.838475Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T15:38:54.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Samba Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:09.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347215"
},
{
"name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347215"
},
{
"name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755193"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2906",
"datePublished": "2026-02-22T01:32:09.390Z",
"dateReserved": "2026-02-20T20:14:40.341Z",
"dateUpdated": "2026-02-24T15:38:54.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:02 – Updated: 2026-02-23 19:13
VLAI?
Title
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
LINXI666 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2905",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:13:05.204806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:13:59.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:02:10.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347214"
},
{
"name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347214"
},
{
"name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755167"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2905",
"datePublished": "2026-02-22T01:02:10.433Z",
"dateReserved": "2026-02-20T20:14:32.380Z",
"dateUpdated": "2026-02-23T19:13:59.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-30023 (GCVE-0-2022-30023)
Vulnerability from cvelistv5 – Published: 2022-06-16 14:28 – Updated: 2024-08-03 06:40
VLAI?
Summary
Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.254Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://tenda.com"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ont.com"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-16T14:28:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://tenda.com"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ont.com"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-30023",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://tenda.com",
"refsource": "MISC",
"url": "http://tenda.com"
},
{
"name": "http://ont.com",
"refsource": "MISC",
"url": "http://ont.com"
},
{
"name": "https://github.com/Haniwa0x01/CVE-2022-30023",
"refsource": "MISC",
"url": "https://github.com/Haniwa0x01/CVE-2022-30023"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-30023",
"datePublished": "2022-06-16T14:28:27",
"dateReserved": "2022-05-02T00:00:00",
"dateUpdated": "2024-08-03T06:40:47.254Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}