Search
Find a vulnerability
Search criteria
14 vulnerabilities found for hg10 by tenda
CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from nvd – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 18:49 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369163 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369163/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11553 | third-party-advisory |
| https://vuldb.com/submit/836778 | third-party-advisory |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | related |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11553",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T18:49:04.954919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T18:49:14.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhihua xie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T17:15:11.855Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369163"
},
{
"name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369163/cti"
},
{
"name": "CVE-2026-11553 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11553"
},
{
"name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836778"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-08T07:48:34.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11553",
"datePublished": "2026-06-08T17:15:11.855Z",
"dateReserved": "2026-06-08T05:43:31.214Z",
"dateUpdated": "2026-06-08T18:49:14.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from nvd – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:55 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369119 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369119/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11499 | third-party-advisory |
| https://vuldb.com/submit/834888 | third-party-advisory |
| https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:55:19.613788Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:55:29.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T07:00:23.672Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369119"
},
{
"name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369119/cti"
},
{
"name": "CVE-2026-11499 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11499"
},
{
"name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834888"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:28:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11499",
"datePublished": "2026-06-08T07:00:23.672Z",
"dateReserved": "2026-06-07T13:23:38.138Z",
"dateUpdated": "2026-06-08T12:55:29.374Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from nvd – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:47 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369118 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369118/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11498 | third-party-advisory |
| https://vuldb.com/submit/834887 | third-party-advisory |
| https://github.com/ssaaaa1234/tenda-hg10-voip-oth… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:47:31.920390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:24.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T06:45:21.289Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369118"
},
{
"name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369118/cti"
},
{
"name": "CVE-2026-11498 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11498"
},
{
"name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834887"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:27:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11498",
"datePublished": "2026-06-08T06:45:21.289Z",
"dateReserved": "2026-06-07T13:22:12.336Z",
"dateUpdated": "2026-06-08T16:22:24.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-6988 (GCVE-0-2026-6988)
Vulnerability from nvd – Published: 2026-04-25 17:00 – Updated: 2026-04-27 14:07
VLAI
EPSS
VEX
Title
Tenda HG10 Boa Service formRouting formRoute buffer overflow
Summary
A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-04-27 14:07 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/359540 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/359540/cti | signaturepermissions-required |
| https://vuldb.com/submit/796427 | third-party-advisory |
| https://github.com/xyh4ck/iot_poc/blob/main/Tenda… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6988",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-27T14:07:39.860516Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-27T14:07:53.405Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Boa Service"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xuanyu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-25T17:00:24.221Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-359540 | Tenda HG10 Boa Service formRouting formRoute buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/359540"
},
{
"name": "VDB-359540 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/359540/cti"
},
{
"name": "Submit #796427 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/796427"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xyh4ck/iot_poc/blob/main/Tenda/HG10/01_Buffer_Overflow_nextHop/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-24T21:28:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Boa Service formRouting formRoute buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-6988",
"datePublished": "2026-04-25T17:00:24.221Z",
"dateReserved": "2026-04-24T19:23:13.271Z",
"dateUpdated": "2026-04-27T14:07:53.405Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1690 (GCVE-0-2026-1690)
Vulnerability from nvd – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:10
VLAI
EPSS
VEX
Title
Tenda HG10 formSysCmd system command injection
Summary
A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:53 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343484 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343484 | signaturepermissions-required |
| https://vuldb.com/?submit.741425 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1690",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:53:41.108984Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:54:08.213Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:10:09.575Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343484 | Tenda HG10 formSysCmd system command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343484"
},
{
"name": "VDB-343484 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343484"
},
{
"name": "Submit #741425 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741425"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 formSysCmd system command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1690",
"datePublished": "2026-01-30T16:32:11.826Z",
"dateReserved": "2026-01-30T07:57:40.795Z",
"dateUpdated": "2026-02-23T09:10:09.575Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1689 (GCVE-0-2026-1689)
Vulnerability from nvd – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:09
VLAI
EPSS
VEX
Title
Tenda HG10 Login formLogin checkUserFromLanOrWan command injection
Summary
A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:51 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343483 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343483 | signaturepermissions-required |
| https://vuldb.com/?submit.741411 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1689",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:51:23.837327Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:51:49.332Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Login Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:09:54.959Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343483 | Tenda HG10 Login formLogin checkUserFromLanOrWan command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343483"
},
{
"name": "VDB-343483 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343483"
},
{
"name": "Submit #741411 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741411"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Login formLogin checkUserFromLanOrWan command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1689",
"datePublished": "2026-01-30T16:32:08.118Z",
"dateReserved": "2026-01-30T07:56:21.633Z",
"dateUpdated": "2026-02-23T09:09:54.959Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1687 (GCVE-0-2026-1687)
Vulnerability from nvd – Published: 2026-01-30 16:02 – Updated: 2026-02-23 09:09
VLAI
EPSS
VEX
Title
Tenda HG10 Boa Webserver formSamba command injection
Summary
A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:26 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343481 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343481 | signaturepermissions-required |
| https://vuldb.com/?submit.741281 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1687",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:26:20.214560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:26:27.737Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Boa Webserver"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:09:26.903Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343481 | Tenda HG10 Boa Webserver formSamba command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343481"
},
{
"name": "VDB-343481 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343481"
},
{
"name": "Submit #741281 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741281"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Boa Webserver formSamba command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1687",
"datePublished": "2026-01-30T16:02:09.067Z",
"dateReserved": "2026-01-30T07:51:50.019Z",
"dateUpdated": "2026-02-23T09:09:26.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 18:49 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369163 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369163/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11553 | third-party-advisory |
| https://vuldb.com/submit/836778 | third-party-advisory |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | related |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11553",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T18:49:04.954919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T18:49:14.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhihua xie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T17:15:11.855Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369163"
},
{
"name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369163/cti"
},
{
"name": "CVE-2026-11553 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11553"
},
{
"name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836778"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-08T07:48:34.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11553",
"datePublished": "2026-06-08T17:15:11.855Z",
"dateReserved": "2026-06-08T05:43:31.214Z",
"dateUpdated": "2026-06-08T18:49:14.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:55 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369119 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369119/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11499 | third-party-advisory |
| https://vuldb.com/submit/834888 | third-party-advisory |
| https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:55:19.613788Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:55:29.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T07:00:23.672Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369119"
},
{
"name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369119/cti"
},
{
"name": "CVE-2026-11499 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11499"
},
{
"name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834888"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:28:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11499",
"datePublished": "2026-06-08T07:00:23.672Z",
"dateReserved": "2026-06-07T13:23:38.138Z",
"dateUpdated": "2026-06-08T12:55:29.374Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
EPSS
VEX
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:47 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369118 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369118/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11498 | third-party-advisory |
| https://vuldb.com/submit/834887 | third-party-advisory |
| https://github.com/ssaaaa1234/tenda-hg10-voip-oth… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:47:31.920390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:24.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T06:45:21.289Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369118"
},
{
"name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369118/cti"
},
{
"name": "CVE-2026-11498 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11498"
},
{
"name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834887"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:27:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11498",
"datePublished": "2026-06-08T06:45:21.289Z",
"dateReserved": "2026-06-07T13:22:12.336Z",
"dateUpdated": "2026-06-08T16:22:24.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-6988 (GCVE-0-2026-6988)
Vulnerability from cvelistv5 – Published: 2026-04-25 17:00 – Updated: 2026-04-27 14:07
VLAI
EPSS
VEX
Title
Tenda HG10 Boa Service formRouting formRoute buffer overflow
Summary
A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-04-27 14:07 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/359540 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/359540/cti | signaturepermissions-required |
| https://vuldb.com/submit/796427 | third-party-advisory |
| https://github.com/xyh4ck/iot_poc/blob/main/Tenda… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6988",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-27T14:07:39.860516Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-27T14:07:53.405Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Boa Service"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xuanyu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-25T17:00:24.221Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-359540 | Tenda HG10 Boa Service formRouting formRoute buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/359540"
},
{
"name": "VDB-359540 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/359540/cti"
},
{
"name": "Submit #796427 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/796427"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xyh4ck/iot_poc/blob/main/Tenda/HG10/01_Buffer_Overflow_nextHop/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-24T21:28:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Boa Service formRouting formRoute buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-6988",
"datePublished": "2026-04-25T17:00:24.221Z",
"dateReserved": "2026-04-24T19:23:13.271Z",
"dateUpdated": "2026-04-27T14:07:53.405Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1690 (GCVE-0-2026-1690)
Vulnerability from cvelistv5 – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:10
VLAI
EPSS
VEX
Title
Tenda HG10 formSysCmd system command injection
Summary
A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:53 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343484 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343484 | signaturepermissions-required |
| https://vuldb.com/?submit.741425 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1690",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:53:41.108984Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:54:08.213Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:10:09.575Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343484 | Tenda HG10 formSysCmd system command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343484"
},
{
"name": "VDB-343484 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343484"
},
{
"name": "Submit #741425 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741425"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 formSysCmd system command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1690",
"datePublished": "2026-01-30T16:32:11.826Z",
"dateReserved": "2026-01-30T07:57:40.795Z",
"dateUpdated": "2026-02-23T09:10:09.575Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1689 (GCVE-0-2026-1689)
Vulnerability from cvelistv5 – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:09
VLAI
EPSS
VEX
Title
Tenda HG10 Login formLogin checkUserFromLanOrWan command injection
Summary
A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:51 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343483 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343483 | signaturepermissions-required |
| https://vuldb.com/?submit.741411 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1689",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:51:23.837327Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:51:49.332Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Login Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:09:54.959Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343483 | Tenda HG10 Login formLogin checkUserFromLanOrWan command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343483"
},
{
"name": "VDB-343483 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343483"
},
{
"name": "Submit #741411 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741411"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Login formLogin checkUserFromLanOrWan command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1689",
"datePublished": "2026-01-30T16:32:08.118Z",
"dateReserved": "2026-01-30T07:56:21.633Z",
"dateUpdated": "2026-02-23T09:09:54.959Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1687 (GCVE-0-2026-1687)
Vulnerability from cvelistv5 – Published: 2026-01-30 16:02 – Updated: 2026-02-23 09:09
VLAI
EPSS
VEX
Title
Tenda HG10 Boa Webserver formSamba command injection
Summary
A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-30 16:26 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.343481 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.343481 | signaturepermissions-required |
| https://vuldb.com/?submit.741281 | third-party-advisory |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | related |
| https://github.com/SunnyYANGyaya/cuicuishark-shee… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1687",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T16:26:20.214560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T16:26:27.737Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Boa Webserver"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "US_HG7_HG9_HG10re_300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Abcd1234 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T09:09:26.903Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-343481 | Tenda HG10 Boa Webserver formSamba command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.343481"
},
{
"name": "VDB-343481 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.343481"
},
{
"name": "Submit #741281 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.741281"
},
{
"tags": [
"related"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-31T10:40:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG10 Boa Webserver formSamba command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1687",
"datePublished": "2026-01-30T16:02:09.067Z",
"dateReserved": "2026-01-30T07:51:50.019Z",
"dateUpdated": "2026-02-23T09:09:26.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}