Search
Find a vulnerability
Search criteria
4 vulnerabilities found for h2offt by insyde
CVE-2021-33834 (GCVE-0-2021-33834)
Vulnerability from nvd – Published: 2023-09-08 00:00 – Updated: 2024-09-26 18:43
VLAI
EPSS
VEX
Summary
An issue was discovered in iscflashx64.sys 3.9.3.0 in Insyde H2OFFT 6.20.00. When handling IOCTL 0x22229a, the input used to allocate a buffer and copy memory is mishandled. This could cause memory corruption or a system crash.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-26 18:43 UTC
CWE
- n/a
Assigner
References
2 references
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:58:23.182Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021004"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-33834",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-26T18:43:33.140037Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-26T18:43:44.319Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in iscflashx64.sys 3.9.3.0 in Insyde H2OFFT 6.20.00. When handling IOCTL 0x22229a, the input used to allocate a buffer and copy memory is mishandled. This could cause memory corruption or a system crash."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-08T01:55:56.453Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.insyde.com/security-pledge"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2021004"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33834",
"datePublished": "2023-09-08T00:00:00.000Z",
"dateReserved": "2021-06-03T00:00:00.000Z",
"dateUpdated": "2024-09-26T18:43:44.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12532 (GCVE-0-2019-12532)
Vulnerability from nvd – Published: 2019-08-26 17:06 – Updated: 2024-08-04 23:24
VLAI
EPSS
VEX
Summary
Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eclypsium.com/2019/08/10/screwed-drivers-… | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2019001 | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
Date Public
2019-08-12 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:38.523Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-08-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T17:06:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-12532",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/",
"refsource": "MISC",
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2019001",
"refsource": "CONFIRM",
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220223-0004/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-12532",
"datePublished": "2019-08-26T17:06:07.000Z",
"dateReserved": "2019-06-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:24:38.523Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33834 (GCVE-0-2021-33834)
Vulnerability from cvelistv5 – Published: 2023-09-08 00:00 – Updated: 2024-09-26 18:43
VLAI
EPSS
VEX
Summary
An issue was discovered in iscflashx64.sys 3.9.3.0 in Insyde H2OFFT 6.20.00. When handling IOCTL 0x22229a, the input used to allocate a buffer and copy memory is mishandled. This could cause memory corruption or a system crash.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-26 18:43 UTC
CWE
- n/a
Assigner
References
2 references
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:58:23.182Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021004"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-33834",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-26T18:43:33.140037Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-26T18:43:44.319Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in iscflashx64.sys 3.9.3.0 in Insyde H2OFFT 6.20.00. When handling IOCTL 0x22229a, the input used to allocate a buffer and copy memory is mishandled. This could cause memory corruption or a system crash."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-08T01:55:56.453Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.insyde.com/security-pledge"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2021004"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33834",
"datePublished": "2023-09-08T00:00:00.000Z",
"dateReserved": "2021-06-03T00:00:00.000Z",
"dateUpdated": "2024-09-26T18:43:44.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12532 (GCVE-0-2019-12532)
Vulnerability from cvelistv5 – Published: 2019-08-26 17:06 – Updated: 2024-08-04 23:24
VLAI
EPSS
VEX
Summary
Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eclypsium.com/2019/08/10/screwed-drivers-… | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2019001 | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
Date Public
2019-08-12 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:38.523Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-08-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T17:06:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-12532",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Insyde software tools may allow an authenticated user to potentially enable escalation of privilege, or information disclosure via local access. This is a software vulnerability, not a firmware issue. Affected tools include: H2OFFT version 3.02~5.28, 100.00.00.00~100.00.08.23 and 200.00.00.01~200.00.00.05, H2OOAE before version 200.00.00.02, H2OSDE before version 200.00.00.07, H2OUVE before version 200.00.02.02, H2OPCM before version 100.00.06.00, H2OELV before version 100.00.02.08."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/",
"refsource": "MISC",
"url": "https://eclypsium.com/2019/08/10/screwed-drivers-signed-sealed-delivered/"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2019001",
"refsource": "CONFIRM",
"url": "https://www.insyde.com/security-pledge/SA-2019001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220223-0004/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220223-0004/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-12532",
"datePublished": "2019-08-26T17:06:07.000Z",
"dateReserved": "2019-06-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:24:38.523Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}