Search criteria

4 vulnerabilities found for h0-ecom100_firmware by hosteng

CVE-2022-3228 (GCVE-0-2022-3228)

Vulnerability from nvd – Published: 2022-10-28 17:17 – Updated: 2025-04-16 16:07
VLAI?
Summary
Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Host Engineering H0-ECOM100 Communications Module Affected: All versions , ≤ Firmware v5.0.155 (custom)
Create a notification for this product.
Credits
David Formby and Caleb Purcell of Fortiphyd Logic reported this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:10.822Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3228",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:49:29.267408Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:07:13.798Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "H0-ECOM100 Communications Module",
          "vendor": "Host Engineering",
          "versions": [
            {
              "lessThanOrEqual": "Firmware v5.0.155",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "David Formby and Caleb Purcell of Fortiphyd Logic reported this vulnerability."
        }
      ],
      "datePublic": "2022-09-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3228",
    "datePublished": "2022-10-28T17:17:46.811Z",
    "dateReserved": "2022-09-15T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:07:13.798Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-25195 (GCVE-0-2020-25195)

Vulnerability from nvd – Published: 2020-12-15 19:38 – Updated: 2024-08-04 15:26
VLAI?
Summary
The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device.
Severity ?
No CVSS data available.
CWE
  • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
Assigner
References
Impacted products
Vendor Product Version
n/a Host Engineering H0-ECOM100 Module Affected: Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior
Affected: Hardware Version 7x with Firmware Versions 4.1.113 and prior
Affected: Hardware Version 9x with Firmware Versions 5.0.149 and prior
    n/a Host Engineering H2-ECOM100 Module Affected: Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior
Affected: Hardware Version 8x with Firmware Versions 5.0.1043 and prior
    n/a Host Engineering H4-ECOM100 Module Affected: Firmware Versions 4.0.2148 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:26:10.231Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Host Engineering H0-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 7x with Firmware Versions 4.1.113 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 9x with Firmware Versions 5.0.149 and prior"
            }
          ]
        },
        {
          "product": "Host Engineering H2-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 8x with Firmware Versions 5.0.1043 and prior"
            }
          ]
        },
        {
          "product": "Host Engineering H4-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware Versions 4.0.2148 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "IMPROPER INPUT VALIDATION CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-15T19:38:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-25195",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Host Engineering H0-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior"
                          },
                          {
                            "version_value": "Hardware Version 7x with Firmware Versions 4.1.113 and prior"
                          },
                          {
                            "version_value": "Hardware Version 9x with Firmware Versions 5.0.149 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Host Engineering H2-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior"
                          },
                          {
                            "version_value": "Hardware Version 8x with Firmware Versions 5.0.1043 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Host Engineering H4-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware Versions 4.0.2148 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER INPUT VALIDATION CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-25195",
    "datePublished": "2020-12-15T19:38:02",
    "dateReserved": "2020-09-04T00:00:00",
    "dateUpdated": "2024-08-04T15:26:10.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3228 (GCVE-0-2022-3228)

Vulnerability from cvelistv5 – Published: 2022-10-28 17:17 – Updated: 2025-04-16 16:07
VLAI?
Summary
Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Host Engineering H0-ECOM100 Communications Module Affected: All versions , ≤ Firmware v5.0.155 (custom)
Create a notification for this product.
Credits
David Formby and Caleb Purcell of Fortiphyd Logic reported this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:10.822Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3228",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:49:29.267408Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:07:13.798Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "H0-ECOM100 Communications Module",
          "vendor": "Host Engineering",
          "versions": [
            {
              "lessThanOrEqual": "Firmware v5.0.155",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "David Formby and Caleb Purcell of Fortiphyd Logic reported this vulnerability."
        }
      ],
      "datePublic": "2022-09-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3228",
    "datePublished": "2022-10-28T17:17:46.811Z",
    "dateReserved": "2022-09-15T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:07:13.798Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-25195 (GCVE-0-2020-25195)

Vulnerability from cvelistv5 – Published: 2020-12-15 19:38 – Updated: 2024-08-04 15:26
VLAI?
Summary
The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device.
Severity ?
No CVSS data available.
CWE
  • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
Assigner
References
Impacted products
Vendor Product Version
n/a Host Engineering H0-ECOM100 Module Affected: Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior
Affected: Hardware Version 7x with Firmware Versions 4.1.113 and prior
Affected: Hardware Version 9x with Firmware Versions 5.0.149 and prior
    n/a Host Engineering H2-ECOM100 Module Affected: Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior
Affected: Hardware Version 8x with Firmware Versions 5.0.1043 and prior
    n/a Host Engineering H4-ECOM100 Module Affected: Firmware Versions 4.0.2148 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:26:10.231Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Host Engineering H0-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 7x with Firmware Versions 4.1.113 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 9x with Firmware Versions 5.0.149 and prior"
            }
          ]
        },
        {
          "product": "Host Engineering H2-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior"
            },
            {
              "status": "affected",
              "version": "Hardware Version 8x with Firmware Versions 5.0.1043 and prior"
            }
          ]
        },
        {
          "product": "Host Engineering H4-ECOM100 Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware Versions 4.0.2148 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "IMPROPER INPUT VALIDATION CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-15T19:38:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-25195",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Host Engineering H0-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Hardware Versions 6x and prior with Firmware Versions 4.0.348 and prior"
                          },
                          {
                            "version_value": "Hardware Version 7x with Firmware Versions 4.1.113 and prior"
                          },
                          {
                            "version_value": "Hardware Version 9x with Firmware Versions 5.0.149 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Host Engineering H2-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Hardware Versions 5x and prior with Firmware Versions 4.0.2148 and prior"
                          },
                          {
                            "version_value": "Hardware Version 8x with Firmware Versions 5.0.1043 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Host Engineering H4-ECOM100 Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware Versions 4.0.2148 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER INPUT VALIDATION CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-345-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-25195",
    "datePublished": "2020-12-15T19:38:02",
    "dateReserved": "2020-09-04T00:00:00",
    "dateUpdated": "2024-08-04T15:26:10.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}