VAR-201903-1402
Vulnerability from variot - Updated: 2024-11-23 22:21Grandstream GXV3370 before 1.0.1.41 and WP820 before 1.0.3.6 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in a /manager?action=getlogcat priority field. Grandstream GXV3370 and WP820 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Both Grandstream GXV3370 and Grandstream WP820 are products of Grandstream. Grandstream GXV3370 is an IP video phone device. Grandstream WP820 is a portable business WiFi phone.
There are security vulnerabilities in Grandstream GXV3370 versions before 1.0.1.41 and WP820 versions before 1.0.3.6. An attacker could use this vulnerability to execute an illegal command
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-1402",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "gxv3370",
"scope": "lt",
"trust": 2.4,
"vendor": "grandstream",
"version": "1.0.1.41"
},
{
"model": "wp820",
"scope": "lt",
"trust": 2.4,
"vendor": "grandstream",
"version": "1.0.3.6"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:grandstream:gxv3370_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:grandstream:wp820_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
}
]
},
"cve": "CVE-2019-10659",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2019-10659",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-42880",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2019-10659",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-10659",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-10659",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-10659",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-42880",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201903-1224",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Grandstream GXV3370 before 1.0.1.41 and WP820 before 1.0.3.6 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in a /manager?action=getlogcat priority field. Grandstream GXV3370 and WP820 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Both Grandstream GXV3370 and Grandstream WP820 are products of Grandstream. Grandstream GXV3370 is an IP video phone device. Grandstream WP820 is a portable business WiFi phone. \n\nThere are security vulnerabilities in Grandstream GXV3370 versions before 1.0.1.41 and WP820 versions before 1.0.3.6. An attacker could use this vulnerability to execute an illegal command",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10659"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNVD",
"id": "CNVD-2019-42880"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-10659",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-42880",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"id": "VAR-201903-1402",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
}
]
},
"last_update_date": "2024-11-23T22:21:44.280000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.grandstream.com/"
},
{
"title": "Patch for Grandstream GXV3370 and Grandstream WP820 command injection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/192497"
},
{
"title": "Grandstream GXV3370 and Grandstream WP820 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=90908"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1"
},
{
"trust": 1.6,
"url": "https://github.com/scarvell/grandstream_exploits"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-10659"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10659"
},
{
"trust": 0.8,
"url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920"
},
{
"trust": 0.6,
"url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl;=1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-11-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"date": "2019-05-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"date": "2019-03-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"date": "2019-03-30T17:29:00.557000",
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-11-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-42880"
},
{
"date": "2019-05-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003020"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1224"
},
{
"date": "2024-11-21T04:19:41.730000",
"db": "NVD",
"id": "CVE-2019-10659"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Grandstream GXV3370 and WP820 Command injection vulnerability in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003020"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1224"
}
],
"trust": 0.6
}
}