Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for gncc_c2_firmware by gncchome

    CVE-2024-31800 (GCVE-0-2024-31800)

    Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-10-30 19:25
    VLAI
    Summary
    Authentication Bypass in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-522 - Insufficiently Protected Credentials
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31800",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-30T19:25:04.591700Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-522",
                    "description": "CWE-522 Insufficiently Protected Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-30T19:25:37.917Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:45:21.996Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31800",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-10-30T19:25:37.917Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-31799 (GCVE-0-2024-31799)

    Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-08-16 17:32
    VLAI
    Summary
    Information Disclosure in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Impacted products
    Vendor Product Version
    gncchome gc2 Affected: 1080p
        cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gc2",
                "vendor": "gncchome",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1080p"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31799",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-16T17:23:41.156357Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-200",
                    "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T17:32:01.177Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Disclosure in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:43:17.463Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31799",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-08-16T17:32:01.177Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-31798 (GCVE-0-2024-31798)

    Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-08-15 17:27
    VLAI
    Summary
    Identical Hardcoded Root Password for All Devices in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-259 - Use of Hard-coded Password
    Assigner
    Impacted products
    Vendor Product Version
    gncchome gncc_c2_firmware Affected: 0 , ≤ * (custom)
        cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gncc_c2_firmware",
                "vendor": "gncchome",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.4,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T17:03:46.353055Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-259",
                    "description": "CWE-259 Use of Hard-coded Password",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-15T17:27:56.814Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Identical Hardcoded Root Password for All Devices in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:40:16.384Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31798",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-08-15T17:27:56.814Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-31798 (GCVE-0-2024-31798)

    Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-08-15 17:27
    VLAI
    Summary
    Identical Hardcoded Root Password for All Devices in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-259 - Use of Hard-coded Password
    Assigner
    Impacted products
    Vendor Product Version
    gncchome gncc_c2_firmware Affected: 0 , ≤ * (custom)
        cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gncc_c2_firmware",
                "vendor": "gncchome",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.4,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T17:03:46.353055Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-259",
                    "description": "CWE-259 Use of Hard-coded Password",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-15T17:27:56.814Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Identical Hardcoded Root Password for All Devices in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:40:16.384Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31798",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-08-15T17:27:56.814Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-31800 (GCVE-0-2024-31800)

    Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-10-30 19:25
    VLAI
    Summary
    Authentication Bypass in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-522 - Insufficiently Protected Credentials
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31800",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-30T19:25:04.591700Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-522",
                    "description": "CWE-522 Insufficiently Protected Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-30T19:25:37.917Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:45:21.996Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31800",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-10-30T19:25:37.917Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-31799 (GCVE-0-2024-31799)

    Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-08-16 17:32
    VLAI
    Summary
    Information Disclosure in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Impacted products
    Vendor Product Version
    gncchome gc2 Affected: 1080p
        cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gc2",
                "vendor": "gncchome",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1080p"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-31799",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-16T17:23:41.156357Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-200",
                    "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T17:32:01.177Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Disclosure in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-15T16:43:17.463Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
            },
            {
              "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-31799",
        "datePublished": "2024-08-15T00:00:00.000Z",
        "dateReserved": "2024-04-05T00:00:00.000Z",
        "dateUpdated": "2024-08-16T17:32:01.177Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }