Search criteria

6 vulnerabilities found for gncc_c2_firmware by gncchome

CVE-2024-31800 (GCVE-0-2024-31800)

Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-10-30 19:25
VLAI?
Summary
Authentication Bypass in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31800",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T19:25:04.591700Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-522",
                "description": "CWE-522 Insufficiently Protected Credentials",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T19:25:37.917Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication Bypass in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:45:21.996182",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31800",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-10-30T19:25:37.917Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-31799 (GCVE-0-2024-31799)

Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-08-16 17:32
VLAI?
Summary
Information Disclosure in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gc2",
            "vendor": "gncchome",
            "versions": [
              {
                "status": "affected",
                "version": "1080p"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "NONE",
              "baseScore": 4.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31799",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:23:41.156357Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-200",
                "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T17:32:01.177Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information Disclosure in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:43:17.463322",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31799",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-08-16T17:32:01.177Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-31798 (GCVE-0-2024-31798)

Vulnerability from nvd – Published: 2024-08-15 00:00 – Updated: 2024-08-15 17:27
VLAI?
Summary
Identical Hardcoded Root Password for All Devices in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gncc_c2_firmware",
            "vendor": "gncchome",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31798",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:03:46.353055Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-259",
                "description": "CWE-259 Use of Hard-coded Password",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:27:56.814Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Identical Hardcoded Root Password for All Devices in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:40:16.384991",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31798",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-08-15T17:27:56.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-31800 (GCVE-0-2024-31800)

Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-10-30 19:25
VLAI?
Summary
Authentication Bypass in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31800",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T19:25:04.591700Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-522",
                "description": "CWE-522 Insufficiently Protected Credentials",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T19:25:37.917Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication Bypass in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to gain a privileged command shell via the UART Debugging Port."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:45:21.996182",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31800",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-10-30T19:25:37.917Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-31799 (GCVE-0-2024-31799)

Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-08-16 17:32
VLAI?
Summary
Information Disclosure in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:gncchome:gc2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gc2",
            "vendor": "gncchome",
            "versions": [
              {
                "status": "affected",
                "version": "1080p"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "NONE",
              "baseScore": 4.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31799",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:23:41.156357Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-200",
                "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T17:32:01.177Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information Disclosure in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:43:17.463322",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31799",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-08-16T17:32:01.177Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-31798 (GCVE-0-2024-31798)

Vulnerability from cvelistv5 – Published: 2024-08-15 00:00 – Updated: 2024-08-15 17:27
VLAI?
Summary
Identical Hardcoded Root Password for All Devices in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:gncchome:gncc_c2_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gncc_c2_firmware",
            "vendor": "gncchome",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-31798",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:03:46.353055Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-259",
                "description": "CWE-259 Use of Hard-coded Password",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:27:56.814Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Identical Hardcoded Root Password for All Devices in GNCC\u0027s GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:40:16.384991",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p"
        },
        {
          "url": "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-31798",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-04-05T00:00:00",
    "dateUpdated": "2024-08-15T17:27:56.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}