Search criteria

1 vulnerability found for fw-1007 by wincofireworks

VAR-201905-0082

Vulnerability from variot - Updated: 2025-01-30 22:24

An exploitable improper access control vulnerability exists in the bluetooth low energy functionality of Winco Fireworks FireFly FW-1007 V2.0. An attacker can connect to the device to trigger this vulnerability. Winco Fireworks FireFly FW-1007 is a firework launch control system. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0082",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fw-1007",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wincofireworks",
        "version": "2.0"
      },
      {
        "model": "firefly fw-1007",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "winco fireworks",
        "version": "2.0"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:wincofireworks:fw-1007_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Discovered by Carl Hurd of Cisco Talos. Timeline 2019-01-23 - Initial Contact 2019-01-24 - Vendor Disclosure; Vendor acknowledged reports 2019-02-19 - 1st follow up (near 30 day); no response 2019-03-28 - 2nd follow up (60 day); no response 2019-04-10 - Notice of 90 day mark approaching 2019-05-08 - Public Release Credit Discovered by Carl Hurd of Cisco Talos.,Carl Hurd of Cisco Talos",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-5014",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2019-5014",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-156449",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "talos-cna@cisco.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2019-5014",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2019-5014",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-5014",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2019-5014",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-5014",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-204",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-156449",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable improper access control vulnerability exists in the bluetooth low energy functionality of Winco Fireworks FireFly FW-1007 V2.0. An attacker can connect to the device to trigger this vulnerability. Winco Fireworks FireFly FW-1007 is a firework launch control system. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5014",
        "trust": 2.6
      },
      {
        "db": "TALOS",
        "id": "TALOS-2019-0772",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204",
        "trust": 0.7
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "id": "VAR-201905-0082",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      }
    ],
    "trust": 0.02
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "vehicle device"
        ],
        "sub_category": "launcher",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ]
  },
  "last_update_date": "2025-01-30T22:24:16.045000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "FireFly",
        "trust": 0.8,
        "url": "https://shootfirefly.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-284",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-306",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2019-0772"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5014"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5014"
      },
      {
        "trust": 0.6,
        "url": "https://www.talosintelligence.com/vulnerability_reports/talos-2019-0772"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-08T00:00:00",
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "date": "2019-06-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "date": "2019-05-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "date": "2019-05-08T17:29:01.410000",
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-156449"
      },
      {
        "date": "2019-06-03T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      },
      {
        "date": "2024-11-21T04:44:11.337000",
        "db": "NVD",
        "id": "CVE-2019-5014"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Winco Fireworks FireFly FW-1007 Access control vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004475"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-204"
      }
    ],
    "trust": 0.6
  }
}