    CVE-2021-40334 (GCVE-0-2021-40334)

    Vulnerability from nvd – Published: 2021-12-02 18:28 – Updated: 2024-09-16 23:11
    VLAI
    Title
    SSH activation problem in the proprietary management protocol (port TCP 5558)
    Summary
    Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Hitachi Energy FOX61x Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Hitachi Energy XCM20 Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Date Public
    2021-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:27:31.884Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FOX61x",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XCM20",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-431",
                  "description": "CWE-431 Missing Handler",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-02T18:28:18.000Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fixed in FOX61x R15A or XMC20 R15A"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SSH activation problem in the proprietary management protocol (port TCP 5558)",
          "workarounds": [
            {
              "lang": "en",
              "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and FOX61x or XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@hitachienergy.com",
              "DATE_PUBLIC": "2021-11-23T11:00:00.000Z",
              "ID": "CVE-2021-40334",
              "STATE": "PUBLIC",
              "TITLE": "SSH activation problem in the proprietary management protocol (port TCP 5558)"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FOX61x",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XCM20",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Hitachi Energy"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-431 Missing Handler"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                },
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fixed in FOX61x R15A or XMC20 R15A"
              }
            ],
            "source": {
              "discovery": "UNKNOWN"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and FOX61x or XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2021-40334",
        "datePublished": "2021-12-02T18:28:18.525Z",
        "dateReserved": "2021-08-31T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:11:57.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-40333 (GCVE-0-2021-40333)

    Vulnerability from nvd – Published: 2021-12-02 18:29 – Updated: 2024-09-17 00:15
    VLAI
    Title
    Weak default credential associated with TCP port 26
    Summary
    Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.
    CWE
    • CWE-521 - Weak Password Requirements
    Assigner
    References
    Impacted products
    Vendor Product Version
    Hitachi Energy FOX61x Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Hitachi Energy XCM20 Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Date Public
    2021-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:27:31.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FOX61x",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XCM20",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "CWE-521 Weak Password Requirements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-02T18:29:36.000Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fixed in FOX61x R14A Hotfix or XMC20 R14A Hotfix\nFixed in FOX61x R15A or XMC20 R15A"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Weak default credential associated with TCP port 26",
          "workarounds": [
            {
              "lang": "en",
              "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed (e.g., traffic to TCP port 26 should be blocked/dropped), and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@hitachienergy.com",
              "DATE_PUBLIC": "2021-11-23T11:00:00.000Z",
              "ID": "CVE-2021-40333",
              "STATE": "PUBLIC",
              "TITLE": "Weak default credential associated with TCP port 26"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FOX61x",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XCM20",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Hitachi Energy"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-521 Weak Password Requirements"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                },
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fixed in FOX61x R14A Hotfix or XMC20 R14A Hotfix\nFixed in FOX61x R15A or XMC20 R15A"
              }
            ],
            "source": {
              "discovery": "UNKNOWN"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed (e.g., traffic to TCP port 26 should be blocked/dropped), and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2021-40333",
        "datePublished": "2021-12-02T18:29:36.828Z",
        "dateReserved": "2021-08-31T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:15:37.686Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-40333 (GCVE-0-2021-40333)

    Vulnerability from cvelistv5 – Published: 2021-12-02 18:29 – Updated: 2024-09-17 00:15
    VLAI
    Title
    Weak default credential associated with TCP port 26
    Summary
    Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.
    CWE
    • CWE-521 - Weak Password Requirements
    Assigner
    References
    Impacted products
    Vendor Product Version
    Hitachi Energy FOX61x Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Hitachi Energy XCM20 Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Date Public
    2021-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:27:31.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FOX61x",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XCM20",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "CWE-521 Weak Password Requirements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-02T18:29:36.000Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fixed in FOX61x R14A Hotfix or XMC20 R14A Hotfix\nFixed in FOX61x R15A or XMC20 R15A"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Weak default credential associated with TCP port 26",
          "workarounds": [
            {
              "lang": "en",
              "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed (e.g., traffic to TCP port 26 should be blocked/dropped), and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@hitachienergy.com",
              "DATE_PUBLIC": "2021-11-23T11:00:00.000Z",
              "ID": "CVE-2021-40333",
              "STATE": "PUBLIC",
              "TITLE": "Weak default credential associated with TCP port 26"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FOX61x",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XCM20",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Hitachi Energy"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-521 Weak Password Requirements"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                },
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fixed in FOX61x R14A Hotfix or XMC20 R14A Hotfix\nFixed in FOX61x R15A or XMC20 R15A"
              }
            ],
            "source": {
              "discovery": "UNKNOWN"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed (e.g., traffic to TCP port 26 should be blocked/dropped), and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2021-40333",
        "datePublished": "2021-12-02T18:29:36.828Z",
        "dateReserved": "2021-08-31T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:15:37.686Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-40334 (GCVE-0-2021-40334)

    Vulnerability from cvelistv5 – Published: 2021-12-02 18:28 – Updated: 2024-09-16 23:11
    VLAI
    Title
    SSH activation problem in the proprietary management protocol (port TCP 5558)
    Summary
    Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Hitachi Energy FOX61x Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Hitachi Energy XCM20 Affected: R15A , < R15A (custom)
    Create a notification for this product.
    Date Public
    2021-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:27:31.884Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FOX61x",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XCM20",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThan": "R15A",
                  "status": "affected",
                  "version": "R15A",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-431",
                  "description": "CWE-431 Missing Handler",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-02T18:28:18.000Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fixed in FOX61x R15A or XMC20 R15A"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SSH activation problem in the proprietary management protocol (port TCP 5558)",
          "workarounds": [
            {
              "lang": "en",
              "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and FOX61x or XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@hitachienergy.com",
              "DATE_PUBLIC": "2021-11-23T11:00:00.000Z",
              "ID": "CVE-2021-40334",
              "STATE": "PUBLIC",
              "TITLE": "SSH activation problem in the proprietary management protocol (port TCP 5558)"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FOX61x",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XCM20",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "R15A",
                                "version_value": "R15A"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Hitachi Energy"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-431 Missing Handler"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                },
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fixed in FOX61x R15A or XMC20 R15A"
              }
            ],
            "source": {
              "discovery": "UNKNOWN"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Recommended security practices and firewall configurations help protecting systems from attacks that originate from outside the network. Such practices include that network management systems and FOX61x or XMC20 networks are typically physically protected from direct access by unauthorized personnel and have no direct connections to the Internet, as well as are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2021-40334",
        "datePublished": "2021-12-02T18:28:18.525Z",
        "dateReserved": "2021-08-31T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:11:57.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }