Search
Find a vulnerability
Search criteria
4 vulnerabilities found for fm\/dab\/tv_transmitter_web_management_system by electrolink
CVE-2025-51040 (GCVE-0-2025-51040)
Vulnerability from nvd – Published: 2025-08-06 00:00 – Updated: 2025-08-06 19:16
VLAI
Summary
Electrolink FM/DAB/TV Transmitter Web Management System Unauthorized access vulnerability via the /FrameSetCore.html endpoint in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-51040",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-06T19:15:22.886074Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-06T19:16:07.143Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Electrolink FM/DAB/TV Transmitter Web Management System Unauthorized access vulnerability via the /FrameSetCore.html endpoint in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-06T14:19:12.283Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/p0et08/Electrolink-FM-DAB-TV"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-51040",
"datePublished": "2025-08-06T00:00:00.000Z",
"dateReserved": "2025-06-16T00:00:00.000Z",
"dateUpdated": "2025-08-06T19:16:07.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-28228 (GCVE-0-2025-28228)
Vulnerability from nvd – Published: 2025-04-18 00:00 – Updated: 2025-04-22 14:52
VLAI
Summary
A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-28228",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T14:52:25.199919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T14:52:55.391Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-28228"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T14:53:16.047Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-28228"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-28228",
"datePublished": "2025-04-18T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2025-04-22T14:52:55.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-51040 (GCVE-0-2025-51040)
Vulnerability from cvelistv5 – Published: 2025-08-06 00:00 – Updated: 2025-08-06 19:16
VLAI
Summary
Electrolink FM/DAB/TV Transmitter Web Management System Unauthorized access vulnerability via the /FrameSetCore.html endpoint in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-51040",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-06T19:15:22.886074Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-06T19:16:07.143Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Electrolink FM/DAB/TV Transmitter Web Management System Unauthorized access vulnerability via the /FrameSetCore.html endpoint in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-06T14:19:12.283Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/p0et08/Electrolink-FM-DAB-TV"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-51040",
"datePublished": "2025-08-06T00:00:00.000Z",
"dateReserved": "2025-06-16T00:00:00.000Z",
"dateUpdated": "2025-08-06T19:16:07.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-28228 (GCVE-0-2025-28228)
Vulnerability from cvelistv5 – Published: 2025-04-18 00:00 – Updated: 2025-04-22 14:52
VLAI
Summary
A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-28228",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T14:52:25.199919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T14:52:55.391Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-28228"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T14:53:16.047Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-28228"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-28228",
"datePublished": "2025-04-18T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2025-04-22T14:52:55.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}