    Flow-X disclosure of sensitive information to unauthenticated users
    Summary
    Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Flow-X Affected: 0 , < 4.0 (semver)
    Create a notification for this product.
    Date Public
    2023-03-31 08:00
    Credits
    ABB would like to thank the following for working with us to help protect customers: Paul Smith of SCADAfence for reporting this vulnerability following coordinated disclosure
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:40:59.772Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A9754\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/173610/ABB-FlowX-4.00-Information-Disclosure.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1258",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-11T18:42:33.492290Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-11T18:42:39.323Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web service"
              ],
              "packageName": "firmware",
              "platforms": [
                "Flow-X embedded hardware"
              ],
              "product": "Flow-X",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB would like to thank the following for working with us to help protect customers: Paul Smith of SCADAfence for reporting this vulnerability following coordinated disclosure"
            }
          ],
          "datePublic": "2023-03-31T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.\u003cp\u003eThis issue affects Flow-X: before 4.0.\u003c/p\u003e"
                }
              ],
              "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-169",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-169 Footprinting"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-20T17:06:55.424Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A9754\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "url": "http://packetstormsecurity.com/files/173610/ABB-FlowX-4.00-Information-Disclosure.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Flow-X disclosure of sensitive information to unauthenticated users",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate\nFlow-X flow computers in secure networks.\nAdditionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS\nsupport has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default\nsince version 3.2.0 (available as of September 2020).\nTo minimize the risk of exposed security information on one device leading to unauthorized access on\nother devices, ABB recommends that customers change the usernames and passwords that are part of\nthe standard application and to use different usernames and password on different devices\n\n\u003cbr\u003e"
                }
              ],
              "value": "To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate\nFlow-X flow computers in secure networks.\nAdditionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS\nsupport has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default\nsince version 3.2.0 (available as of September 2020).\nTo minimize the risk of exposed security information on one device leading to unauthorized access on\nother devices, ABB recommends that customers change the usernames and passwords that are part of\nthe standard application and to use different usernames and password on different devices"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2023-1258",
        "datePublished": "2023-03-31T07:56:05.133Z",
        "dateReserved": "2023-03-07T16:57:05.254Z",
        "dateUpdated": "2025-02-13T16:39:19.647Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1258 (GCVE-0-2023-1258)

    Vulnerability from cvelistv5 – Published: 2023-03-31 07:56 – Updated: 2025-02-13 16:39
    VLAI
    Title
    Flow-X disclosure of sensitive information to unauthenticated users
    Summary
    Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Flow-X Affected: 0 , < 4.0 (semver)
    Create a notification for this product.
    Date Public
    2023-03-31 08:00
    Credits
    ABB would like to thank the following for working with us to help protect customers: Paul Smith of SCADAfence for reporting this vulnerability following coordinated disclosure
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:40:59.772Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A9754\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/173610/ABB-FlowX-4.00-Information-Disclosure.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1258",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-11T18:42:33.492290Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-11T18:42:39.323Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web service"
              ],
              "packageName": "firmware",
              "platforms": [
                "Flow-X embedded hardware"
              ],
              "product": "Flow-X",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB would like to thank the following for working with us to help protect customers: Paul Smith of SCADAfence for reporting this vulnerability following coordinated disclosure"
            }
          ],
          "datePublic": "2023-03-31T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.\u003cp\u003eThis issue affects Flow-X: before 4.0.\u003c/p\u003e"
                }
              ],
              "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-169",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-169 Footprinting"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-20T17:06:55.424Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A9754\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "url": "http://packetstormsecurity.com/files/173610/ABB-FlowX-4.00-Information-Disclosure.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Flow-X disclosure of sensitive information to unauthenticated users",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate\nFlow-X flow computers in secure networks.\nAdditionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS\nsupport has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default\nsince version 3.2.0 (available as of September 2020).\nTo minimize the risk of exposed security information on one device leading to unauthorized access on\nother devices, ABB recommends that customers change the usernames and passwords that are part of\nthe standard application and to use different usernames and password on different devices\n\n\u003cbr\u003e"
                }
              ],
              "value": "To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate\nFlow-X flow computers in secure networks.\nAdditionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS\nsupport has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default\nsince version 3.2.0 (available as of September 2020).\nTo minimize the risk of exposed security information on one device leading to unauthorized access on\nother devices, ABB recommends that customers change the usernames and passwords that are part of\nthe standard application and to use different usernames and password on different devices"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2023-1258",
        "datePublished": "2023-03-31T07:56:05.133Z",
        "dateReserved": "2023-03-07T16:57:05.254Z",
        "dateUpdated": "2025-02-13T16:39:19.647Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }