Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for fd8136 by vivotek

    VAR-201907-1136

    Vulnerability from variot - Updated: 2024-11-23 23:01

    Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1136",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:vivotek:fd8136_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          }
        ]
      },
      "cve": "CVE-2018-14494",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-14494",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22783",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124659",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-14494",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14494",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14494",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22783",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-552",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124659",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14494",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "id": "VAR-201907-1136",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:01:47.836000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.3,
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14494"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14494"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "date": "2019-07-10T13:15:10.590000",
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "date": "2020-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "date": "2024-11-21T03:49:11.077000",
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Command injection vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1137

    Vulnerability from variot - Updated: 2024-11-23 22:29

    Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1137",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:vivotek:fd8136_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          }
        ]
      },
      "cve": "CVE-2018-14495",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-14495",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22270",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124660",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-14495",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14495",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14495",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22270",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-553",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124660",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14495",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14495",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "id": "VAR-201907-1137",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:29:59.723000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.2,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.4,
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14495"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14495"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "date": "2019-07-10T14:15:10.637000",
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "date": "2020-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "date": "2024-11-21T03:49:11.240000",
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Command injection vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1138

    Vulnerability from variot - Updated: 2024-11-23 21:37

    Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1138",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:vivotek:fd8136_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          }
        ]
      },
      "cve": "CVE-2018-14496",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-14496",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22271",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-124661",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-14496",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14496",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14496",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22271",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-555",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124661",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14496",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "id": "VAR-201907-1138",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:37:04.458000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.3,
            "url": "https://www.vdalabs.com/2018/11/29/professional-iot-hacking-series-hunting-remote-memory-corruption/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14496"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14496"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "date": "2019-07-10T14:15:10.730000",
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "date": "2024-11-21T03:49:11.420000",
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Device buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          }
        ],
        "trust": 0.6
      }
    }