    6 vulnerabilities found for factorytalk by rockwellautomation

    VAR-201204-0173

    Vulnerability from variot - Updated: 2025-04-11 23:04

    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet. Rockwell Automation is a provider of industrial automation, control and information technology solutions. Rockwell Automation FactoryTalk Activation Server RNADiagReceiver has errors in processing packets. Submitting a packet containing more than 2000 bytes to UDP port 4445 can result in no subsequent connections. An attacker can exploit these issues to crash the affected application, denying service to legitimate users

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201204-0173",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "automation factorytalk activation server",
            "scope": "eq",
            "trust": 1.7,
            "vendor": "rockwall",
            "version": "3.2"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.7,
            "vendor": "rockwall",
            "version": "500019"
          },
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "cpr9"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "18"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "20"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "17"
          },
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "cpr9_sr5"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "19"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "500018"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "500017"
          },
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "rockwell automation",
            "version": "cpr9 to  sr5"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "rockwell automation",
            "version": "17 to  20"
          },
          {
            "model": null,
            "scope": null,
            "trust": 0.6,
            "vendor": "no",
            "version": null
          },
          {
            "model": "cpr9",
            "scope": null,
            "trust": 0.4,
            "vendor": "factorytalk",
            "version": null
          },
          {
            "model": "cpr9 sr5",
            "scope": null,
            "trust": 0.4,
            "vendor": "factorytalk",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "17"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "18"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "19"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "20"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rockwall",
            "version": "500018*"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rockwall",
            "version": "500017*"
          },
          {
            "model": "automation factorytalk cpr9-sr5",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr4",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr3",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr2",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr1",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "rockwall",
            "version": "0"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rockwall",
            "version": "500019*"
          },
          {
            "model": "automation factorytalk activation server",
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rockwall",
            "version": "3.2*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:rockwellautomation:factorytalk",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:rockwellautomation:rslogix_5000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Luigi Auriemma",
        "sources": [
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          }
        ],
        "trust": 0.9
      },
      "cve": "CVE-2012-0221",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2012-0221",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2012-8875",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "fa04ef80-2353-11e6-abef-000c29c66e3d",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "f0999908-1f77-11e6-abef-000c29c66e3d",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-53502",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2012-0221",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2012-0221",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2012-8875",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201204-003",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "fa04ef80-2353-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "f0999908-1f77-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-53502",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet. Rockwell Automation is a provider of industrial automation, control and information technology solutions. Rockwell Automation FactoryTalk Activation Server RNADiagReceiver has errors in processing packets. Submitting a packet containing more than 2000 bytes to UDP port 4445 can result in no subsequent connections. \nAn attacker can exploit these issues to crash the affected  application, denying service to legitimate users",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          }
        ],
        "trust": 4.32
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-53502",
            "trust": 0.1,
            "type": "unknown"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2012-0221",
            "trust": 4.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-12-088-01",
            "trust": 3.4
          },
          {
            "db": "BID",
            "id": "51444",
            "trust": 2.1
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003",
            "trust": 1.5
          },
          {
            "db": "ICS CERT ALERT",
            "id": "ICS-ALERT-12-017-01",
            "trust": 1.1
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875",
            "trust": 1.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "7D70A8CF-463F-11E9-B5ED-000C29342CB1",
            "trust": 0.2
          },
          {
            "db": "IVD",
            "id": "FA04EF80-2353-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "IVD",
            "id": "EF44EA94-1F77-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "IVD",
            "id": "F0999908-1F77-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-72115",
            "trust": 0.1
          },
          {
            "db": "EXPLOIT-DB",
            "id": "36570",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "id": "VAR-201204-0173",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          }
        ],
        "trust": 3.5250000000000004
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 2.6
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          }
        ]
      },
      "last_update_date": "2025-04-11T23:04:14.194000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "RSLogix 5000",
            "trust": 0.8,
            "url": "http://www.rockwellautomation.com/rockwellsoftware/design/rslogix5000/"
          },
          {
            "title": "FactoryTalk",
            "trust": 0.8,
            "url": "http://www.rockwellautomation.com/rockwellsoftware/factorytalk/"
          },
          {
            "title": "Rockwell Automation Allen-Bradley FactoryTalk Input Validation Vulnerability Patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/36065"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-20",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-088-01.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
          },
          {
            "trust": 1.5,
            "url": "http://aluigi.altervista.org/adv/rnadiagreceiver_1-adv.txt"
          },
          {
            "trust": 1.1,
            "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-12-017-01.pdf"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-0221"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-0221"
          },
          {
            "trust": 0.6,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-12-088-01"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/bid/51444"
          },
          {
            "trust": 0.3,
            "url": "http://www.rockwellautomation.com/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2012-04-05T00:00:00",
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "date": "2012-04-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "date": "2012-01-17T00:00:00",
            "db": "BID",
            "id": "51444"
          },
          {
            "date": "2012-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "date": "1900-01-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "date": "2012-04-02T18:55:01.043000",
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "date": "2012-04-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-53502"
          },
          {
            "date": "2012-03-28T22:10:00",
            "db": "BID",
            "id": "51444"
          },
          {
            "date": "2012-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2012-001982"
          },
          {
            "date": "2012-01-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          },
          {
            "date": "2025-04-11T00:51:21.963000",
            "db": "NVD",
            "id": "CVE-2012-0221"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          }
        ],
        "trust": 1.2
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rockwell Automation Allen-Bradley FactoryTalk Input validation vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8875"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          }
        ],
        "trust": 1.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Input validation",
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8cf-463f-11e9-b5ed-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "fa04ef80-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "ef44ea94-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "IVD",
            "id": "f0999908-1f77-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-003"
          }
        ],
        "trust": 1.4
      }
    }

    VAR-201204-0174

    Vulnerability from variot - Updated: 2025-04-11 23:04

    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet. Rockwell Automation is a provider of industrial automation, control and information technology solutions. Rockwell Automation FactoryTalk Activation Server RNADiagReceiver has errors in processing packets. Submitting a packet containing more than 2000 bytes to UDP port 4445 can result in no subsequent connections. An attacker can exploit these issues to crash the affected application, denying service to legitimate users

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201204-0174",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "cpr9"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "18"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "20"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "17"
          },
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "cpr9_sr5"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "rockwellautomation",
            "version": "19"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "500018"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "500019"
          },
          {
            "model": "automation rslogix",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "500017"
          },
          {
            "model": "automation factorytalk activation server",
            "scope": "eq",
            "trust": 1.5,
            "vendor": "rockwall",
            "version": "3.2"
          },
          {
            "model": "factorytalk",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "rockwell automation",
            "version": "cpr9 to  sr5"
          },
          {
            "model": "rslogix 5000",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "rockwell automation",
            "version": "17 to  20"
          },
          {
            "model": null,
            "scope": null,
            "trust": 0.6,
            "vendor": "no",
            "version": null
          },
          {
            "model": "cpr9",
            "scope": null,
            "trust": 0.4,
            "vendor": "factorytalk",
            "version": null
          },
          {
            "model": "cpr9 sr5",
            "scope": null,
            "trust": 0.4,
            "vendor": "factorytalk",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "17"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "18"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "19"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "rslogix 5000",
            "version": "20"
          },
          {
            "model": "automation factorytalk cpr9-sr5",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr4",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr3",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr2",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9-sr1",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk cpr9",
            "scope": null,
            "trust": 0.3,
            "vendor": "rockwall",
            "version": null
          },
          {
            "model": "automation factorytalk",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "rockwall",
            "version": "0"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/a:rockwellautomation:factorytalk",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/a:rockwellautomation:rslogix_5000",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Luigi Auriemma",
        "sources": [
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          }
        ],
        "trust": 0.9
      },
      "cve": "CVE-2012-0222",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2012-0222",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2012-8874",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "7d70a8d0-463f-11e9-be91-000c29342cb1",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "f9f79006-2353-11e6-abef-000c29c66e3d",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-53503",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2012-0222",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2012-0222",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2012-8874",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201204-004",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "7d70a8d0-463f-11e9-be91-000c29342cb1",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "f9f79006-2353-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-53503",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet. Rockwell Automation is a provider of industrial automation, control and information technology solutions. Rockwell Automation FactoryTalk Activation Server RNADiagReceiver has errors in processing packets. Submitting a packet containing more than 2000 bytes to UDP port 4445 can result in no subsequent connections. \nAn attacker can exploit these issues to crash the affected  application, denying service to legitimate users",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          }
        ],
        "trust": 3.96
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2012-0222",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-12-088-01",
            "trust": 3.4
          },
          {
            "db": "BID",
            "id": "51444",
            "trust": 2.1
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004",
            "trust": 1.1
          },
          {
            "db": "ICS CERT ALERT",
            "id": "ICS-ALERT-12-017-01",
            "trust": 1.1
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874",
            "trust": 1.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190",
            "trust": 0.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "7D70A8D0-463F-11E9-BE91-000C29342CB1",
            "trust": 0.2
          },
          {
            "db": "IVD",
            "id": "F9F79006-2353-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "id": "VAR-201204-0174",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          }
        ],
        "trust": 3.125
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 2.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          }
        ]
      },
      "last_update_date": "2025-04-11T23:04:14.137000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "RSLogix 5000",
            "trust": 0.8,
            "url": "http://www.rockwellautomation.com/rockwellsoftware/design/rslogix5000/"
          },
          {
            "title": "FactoryTalk",
            "trust": 0.8,
            "url": "http://www.rockwellautomation.com/rockwellsoftware/factorytalk/"
          },
          {
            "title": "Patch for Rockwell Automation Allen-Bradley FactoryTalk Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/36064"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-088-01.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
          },
          {
            "trust": 1.5,
            "url": "http://aluigi.altervista.org/adv/rnadiagreceiver_1-adv.txt"
          },
          {
            "trust": 1.1,
            "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-12-017-01.pdf"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-0222"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-0222"
          },
          {
            "trust": 0.6,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-12-088-01"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/bid/51444"
          },
          {
            "trust": 0.3,
            "url": "http://www.rockwellautomation.com/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "db": "BID",
            "id": "51444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2012-04-05T00:00:00",
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "date": "2012-04-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "date": "2012-01-17T00:00:00",
            "db": "BID",
            "id": "51444"
          },
          {
            "date": "2012-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "date": "1900-01-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "date": "2012-04-02T18:55:01.090000",
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0190"
          },
          {
            "date": "2012-01-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-0189"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "date": "2012-04-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-53503"
          },
          {
            "date": "2012-03-28T22:10:00",
            "db": "BID",
            "id": "51444"
          },
          {
            "date": "2012-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2012-001983"
          },
          {
            "date": "2012-01-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "date": "2012-04-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          },
          {
            "date": "2025-04-11T00:51:21.963000",
            "db": "NVD",
            "id": "CVE-2012-0222"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201201-287"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          }
        ],
        "trust": 1.2
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rockwell Automation Allen-Bradley FactoryTalk Buffer Overflow Vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2012-8874"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          }
        ],
        "trust": 1.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer overflow",
        "sources": [
          {
            "db": "IVD",
            "id": "7d70a8d0-463f-11e9-be91-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "f9f79006-2353-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201204-004"
          }
        ],
        "trust": 1.0
      }
    }

    CVE-2012-0222 (GCVE-0-2012-0222)

    Vulnerability from nvd – Published: 2012-04-02 18:00 – Updated: 2024-09-16 19:50
    VLAI
    Summary
    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T18:16:19.673Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-04-02T18:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-0222",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
                  "refsource": "MISC",
                  "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-0222",
        "datePublished": "2012-04-02T18:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:50:52.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-0221 (GCVE-0-2012-0221)

    Vulnerability from nvd – Published: 2012-04-02 18:00 – Updated: 2024-09-17 01:11
    VLAI
    Summary
    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T18:16:19.676Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-04-02T18:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-0221",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
                  "refsource": "MISC",
                  "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-0221",
        "datePublished": "2012-04-02T18:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:11:29.822Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-0222 (GCVE-0-2012-0222)

    Vulnerability from cvelistv5 – Published: 2012-04-02 18:00 – Updated: 2024-09-16 19:50
    VLAI
    Summary
    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T18:16:19.673Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-04-02T18:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-0222",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
                  "refsource": "MISC",
                  "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-0222",
        "datePublished": "2012-04-02T18:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:50:52.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-0221 (GCVE-0-2012-0221)

    Vulnerability from cvelistv5 – Published: 2012-04-02 18:00 – Updated: 2024-09-17 01:11
    VLAI
    Summary
    The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T18:16:19.676Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-04-02T18:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2012-0221",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
                  "refsource": "MISC",
                  "url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2012-0221",
        "datePublished": "2012-04-02T18:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:11:29.822Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",