Search

Find a vulnerability

Search criteria

    33 vulnerabilities found for f1202 by tenda

    CVE-2026-9431 (GCVE-0-2026-9431)

    Vulnerability from nvd – Published: 2026-05-25 05:45 – Updated: 2026-05-26 13:12
    VLAI
    Title
    Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9431",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-26T13:12:02.867879Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-26T13:12:09.259Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:45:10.169Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365412 | Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365412"
            },
            {
              "name": "VDB-365412 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365412/cti"
            },
            {
              "name": "Submit #813916 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813916"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_35/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9431",
        "datePublished": "2026-05-25T05:45:10.169Z",
        "dateReserved": "2026-05-24T07:03:29.836Z",
        "dateUpdated": "2026-05-26T13:12:09.259Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9430 (GCVE-0-2026-9430)

    Vulnerability from nvd – Published: 2026-05-25 05:30 – Updated: 2026-05-28 12:38
    VLAI
    Title
    Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow
    Summary
    A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9430",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T12:37:19.410093Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T12:38:04.357Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:30:12.026Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365411 | Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365411"
            },
            {
              "name": "VDB-365411 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365411/cti"
            },
            {
              "name": "Submit #813915 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813915"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_32/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9430",
        "datePublished": "2026-05-25T05:30:12.026Z",
        "dateReserved": "2026-05-24T07:03:24.648Z",
        "dateUpdated": "2026-05-28T12:38:04.357Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9429 (GCVE-0-2026-9429)

    Vulnerability from nvd – Published: 2026-05-25 05:15 – Updated: 2026-05-26 16:05
    VLAI
    Title
    Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow
    Summary
    A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/365410 vdb-entrytechnical-description
    https://vuldb.com/vuln/365410/cti signaturepermissions-required
    https://vuldb.com/submit/813912 third-party-advisory
    https://github.com/Litengzheng/vuldb_new2/blob/ma… exploit
    https://www.tenda.com.cn/ broken-linkproduct
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9429",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-26T16:05:34.410649Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-26T16:05:41.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:15:09.759Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365410 | Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365410"
            },
            {
              "name": "VDB-365410 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365410/cti"
            },
            {
              "name": "Submit #813912 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813912"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_31/README.md"
            },
            {
              "tags": [
                "broken-link",
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9429",
        "datePublished": "2026-05-25T05:15:09.759Z",
        "dateReserved": "2026-05-24T07:03:22.153Z",
        "dateUpdated": "2026-05-26T16:05:41.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9428 (GCVE-0-2026-9428)

    Vulnerability from nvd – Published: 2026-05-25 05:00 – Updated: 2026-05-28 18:37
    VLAI
    Title
    Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow
    Summary
    A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9428",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T18:36:36.235807Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T18:37:05.367Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:00:14.895Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365409 | Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365409"
            },
            {
              "name": "VDB-365409 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365409/cti"
            },
            {
              "name": "Submit #813911 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813911"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_29/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9428",
        "datePublished": "2026-05-25T05:00:14.895Z",
        "dateReserved": "2026-05-24T07:03:19.502Z",
        "dateUpdated": "2026-05-28T18:37:05.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9431 (GCVE-0-2026-9431)

    Vulnerability from cvelistv5 – Published: 2026-05-25 05:45 – Updated: 2026-05-26 13:12
    VLAI
    Title
    Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9431",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-26T13:12:02.867879Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-26T13:12:09.259Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:45:10.169Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365412 | Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365412"
            },
            {
              "name": "VDB-365412 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365412/cti"
            },
            {
              "name": "Submit #813916 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813916"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_35/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9431",
        "datePublished": "2026-05-25T05:45:10.169Z",
        "dateReserved": "2026-05-24T07:03:29.836Z",
        "dateUpdated": "2026-05-26T13:12:09.259Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9430 (GCVE-0-2026-9430)

    Vulnerability from cvelistv5 – Published: 2026-05-25 05:30 – Updated: 2026-05-28 12:38
    VLAI
    Title
    Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow
    Summary
    A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9430",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T12:37:19.410093Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T12:38:04.357Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:30:12.026Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365411 | Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365411"
            },
            {
              "name": "VDB-365411 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365411/cti"
            },
            {
              "name": "Submit #813915 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813915"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_32/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9430",
        "datePublished": "2026-05-25T05:30:12.026Z",
        "dateReserved": "2026-05-24T07:03:24.648Z",
        "dateUpdated": "2026-05-28T12:38:04.357Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9429 (GCVE-0-2026-9429)

    Vulnerability from cvelistv5 – Published: 2026-05-25 05:15 – Updated: 2026-05-26 16:05
    VLAI
    Title
    Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow
    Summary
    A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/365410 vdb-entrytechnical-description
    https://vuldb.com/vuln/365410/cti signaturepermissions-required
    https://vuldb.com/submit/813912 third-party-advisory
    https://github.com/Litengzheng/vuldb_new2/blob/ma… exploit
    https://www.tenda.com.cn/ broken-linkproduct
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9429",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-26T16:05:34.410649Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-26T16:05:41.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:15:09.759Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365410 | Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365410"
            },
            {
              "name": "VDB-365410 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365410/cti"
            },
            {
              "name": "Submit #813912 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813912"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_31/README.md"
            },
            {
              "tags": [
                "broken-link",
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9429",
        "datePublished": "2026-05-25T05:15:09.759Z",
        "dateReserved": "2026-05-24T07:03:22.153Z",
        "dateUpdated": "2026-05-26T16:05:41.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9428 (GCVE-0-2026-9428)

    Vulnerability from cvelistv5 – Published: 2026-05-25 05:00 – Updated: 2026-05-28 18:37
    VLAI
    Title
    Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow
    Summary
    A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda F1202 Affected: 1.2.0.20(408)
        cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    LtzHuster2 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9428",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-28T18:36:36.235807Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-28T18:37:05.367Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "F1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.20(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LtzHuster2 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-25T05:00:14.895Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365409 | Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/365409"
            },
            {
              "name": "VDB-365409 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365409/cti"
            },
            {
              "name": "Submit #813911 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813911"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_29/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T09:08:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9428",
        "datePublished": "2026-05-25T05:00:14.895Z",
        "dateReserved": "2026-05-24T07:03:19.502Z",
        "dateUpdated": "2026-05-28T18:37:05.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-202403-3020

    Vulnerability from variot - Updated: 2025-12-19 23:02

    Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. This vulnerability stems from the fact that the page parameter of the fromAddressNat method fails to properly validate the length of the input data. An attacker could exploit this vulnerability to cause a denial-of-service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3020",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "cve": "CVE-2024-30639",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-30668",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-30639",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020495",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30639",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020495",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-30668",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. This vulnerability stems from the fact that the `page` parameter of the `fromAddressNat` method fails to properly validate the length of the input data. An attacker could exploit this vulnerability to cause a denial-of-service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30639",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "id": "VAR-202403-3020",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          }
        ]
      },
      "last_update_date": "2025-12-19T23:02:31.223000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 stack buffer overflow vulnerability in the fromAddressNat method.",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/781366"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromaddressnat_page.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30639"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "date": "2024-03-29T14:15:14.837000",
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30668"
          },
          {
            "date": "2025-03-17T03:05:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          },
          {
            "date": "2025-03-13T21:25:45.667000",
            "db": "NVD",
            "id": "CVE-2024-30639"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020495"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-3049

    Vulnerability from variot - Updated: 2025-12-19 22:59

    Tenda F1202 v1.2.0.20(408) has a command injection vulnerablility in the formWriteFacMac function in the mac parameter. Shenzhen Tenda Technology Co.,Ltd. of F1202 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3049",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "cve": "CVE-2024-30637",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-30669",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-30637",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020497",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30637",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020497",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-30669",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a command injection vulnerablility in the formWriteFacMac function in the mac parameter. Shenzhen Tenda Technology Co.,Ltd. of F1202 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30637",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "id": "VAR-202403-3049",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          }
        ]
      },
      "last_update_date": "2025-12-19T22:59:41.207000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 formWriteFacMac method command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/781371"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/formwritefacmac.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30637"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "date": "2024-03-29T14:15:14.727000",
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30669"
          },
          {
            "date": "2025-03-17T03:05:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          },
          {
            "date": "2025-03-13T21:26:03.370000",
            "db": "NVD",
            "id": "CVE-2024-30637"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020497"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-3087

    Vulnerability from variot - Updated: 2025-12-19 22:35

    Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. This vulnerability stems from the fact that the mitInterface parameter of the fromAddressNat method fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code on the system or cause a denial-of-service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3087",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "cve": "CVE-2024-30634",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-30667",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-30634",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.0,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020505",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30634",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020505",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-30667",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. This vulnerability stems from the fact that the `mitInterface` parameter of the `fromAddressNat` method fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code on the system or cause a denial-of-service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30634",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "id": "VAR-202403-3087",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          }
        ]
      },
      "last_update_date": "2025-12-19T22:35:30.358000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 buffer overflow vulnerability in the fromAddressNat method",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/781361"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromaddressnat_mitinterface.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30634"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "date": "2024-03-29T14:15:14.550000",
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-30667"
          },
          {
            "date": "2025-03-17T03:16:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          },
          {
            "date": "2025-03-13T21:26:28.617000",
            "db": "NVD",
            "id": "CVE-2024-30634"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020505"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-3247

    Vulnerability from variot - Updated: 2025-08-15 05:48

    Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm function. Shenzhen Tenda Technology Co.,Ltd. of F1202 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, boasting a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the failure of the funcpara1 parameter in the formSetCfm method to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3247",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "cve": "CVE-2024-30635",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-18173",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-30635",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020498",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30635",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020498",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18173",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm function. Shenzhen Tenda Technology Co.,Ltd. of F1202 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, boasting a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the failure of the funcpara1 parameter in the formSetCfm method to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30635",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "id": "VAR-202403-3247",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:48:51.283000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 formSetCfm method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718056"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/formsetcfm.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30635"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "date": "2024-03-29T14:15:14.607000",
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18173"
          },
          {
            "date": "2025-03-17T03:05:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          },
          {
            "date": "2025-03-13T21:26:21.357000",
            "db": "NVD",
            "id": "CVE-2024-30635"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020498"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-3334

    Vulnerability from variot - Updated: 2025-08-15 05:46

    Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, boasting a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the PPPOEPassword parameter in the formQuickIndex method failing to properly validate the length of the input data. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3334",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "cve": "CVE-2024-30636",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-18172",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-30636",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020521",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30636",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020521",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18172",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, boasting a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the PPPOEPassword parameter in the formQuickIndex method failing to properly validate the length of the input data. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30636",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "id": "VAR-202403-3334",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:46:05.659000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 formQuickIndex method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718046"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/formquickindex.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30636"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "date": "2024-03-29T14:15:14.663000",
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18172"
          },
          {
            "date": "2025-03-17T07:50:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          },
          {
            "date": "2025-03-13T21:26:12.620000",
            "db": "NVD",
            "id": "CVE-2024-30636"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020521"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-3212

    Vulnerability from variot - Updated: 2025-08-15 05:41

    Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Information may be tampered with. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the failure of the entries parameter of the fromAddressNat method to properly validate the length of the input data. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-3212",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "cve": "CVE-2024-30638",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-18174",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-30638",
                "impactScore": 1.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020496",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-30638",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020496",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18174",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of F1202 A stack-based buffer overflow vulnerability exists in the firmware.Information may be tampered with. The Tenda F1202 is an enterprise-grade dual-band wireless router that supports both 2.4GHz and 5GHz bands, with a maximum transmission rate of 1200Mbps. It is equipped with four 5dBi antennas for enhanced signal coverage. This vulnerability stems from the failure of the entries parameter of the fromAddressNat method to properly validate the length of the input data. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-30638",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "id": "VAR-202403-3212",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          }
        ],
        "trust": 0.82607656
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:41:28.440000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda F1202 fromAddressNat method entries parameter buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718066"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromaddressnat_entrys.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-30638"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "date": "2025-03-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "date": "2024-03-29T14:15:14.780000",
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18174"
          },
          {
            "date": "2025-03-17T03:05:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          },
          {
            "date": "2025-03-13T21:25:55.883000",
            "db": "NVD",
            "id": "CVE-2024-30638"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020496"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201705-3846

    Vulnerability from variot - Updated: 2025-04-20 23:40

    There is a debug-interface vulnerability on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). After connecting locally to a router in a wired or wireless manner, one can bypass intended access restrictions by sending shell commands directly and reading their results, or by entering shell commands that change this router's username and password. plural Tenda Router (FH1202/F1202/F1200) Debug interface contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A security bypass vulnerability exists in the TendaFH1202, F1202, and F1200 routers using firmware prior to 1.2.0.20

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3846",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fh1202",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1202",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "f1202",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "fh1202",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. f1200",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. f1202",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. fh1202",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:tenda:f1200_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:f1202_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:fh1202_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          }
        ]
      },
      "cve": "CVE-2017-9138",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CVE-2017-9138",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-07749",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "VHN-117341",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2017-9138",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9138",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9138",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-07749",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201705-916",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117341",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "There is a debug-interface vulnerability on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). After connecting locally to a router in a wired or wireless manner, one can bypass intended access restrictions by sending shell commands directly and reading their results, or by entering shell commands that change this router\u0027s username and password. plural Tenda Router (FH1202/F1202/F1200) Debug interface contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A security bypass vulnerability exists in the TendaFH1202, F1202, and F1200 routers using firmware prior to 1.2.0.20",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9138",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "id": "VAR-201705-3846",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          }
        ],
        "trust": 0.99994304
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:40:08.776000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Overview-Tenda-All For Better NetWorking",
            "trust": 0.8,
            "url": "http://www.tendacn.com/en/2017.html"
          },
          {
            "title": "TendaFH1202/F1202 and F1200 router security bypass vulnerability patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/94527"
          },
          {
            "title": "Tenda FH1202 , F1202  and F1200 Repair measures for router security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70408"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://www.tendacn.com/en/2017.html"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9138"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9138"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-31T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "date": "2017-05-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "date": "2017-06-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "date": "2017-05-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "date": "2017-05-21T22:29:00.180000",
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-31T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-07749"
          },
          {
            "date": "2017-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117341"
          },
          {
            "date": "2017-06-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          },
          {
            "date": "2017-05-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9138"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "specific network environment",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Tenda Router debug interface buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004377"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer overflow",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-916"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201705-3847

    Vulnerability from variot - Updated: 2025-04-20 23:32

    There is a stack-based buffer overflow on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). Crafted POST requests to an unspecified URL result in DoS, interrupting the HTTP service (used to login to the web UI of a router) for 1 to 2 seconds. plural Tenda Router (FH1202/F1202/F1200) Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaFH1202, F1202 and F1200 are all wireless router products of Tenda

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3847",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fh1202",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1202",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "f1202",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "fh1202",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. f1200",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. f1202",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "tenda technology co.,ltd. fh1202",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          },
          {
            "model": "f1200",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tendacn",
            "version": "1.2.0.19"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:tenda:f1200_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:f1202_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:fh1202_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          }
        ]
      },
      "cve": "CVE-2017-9139",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 2.7,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 5.1,
                "id": "CVE-2017-9139",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2017-07750",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 2.7,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 5.1,
                "id": "VHN-117342",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:S/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "LOW",
                "baseScore": 3.5,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.1,
                "id": "CVE-2017-9139",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9139",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9139",
                "trust": 0.8,
                "value": "Low"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-07750",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201705-915",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117342",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "There is a stack-based buffer overflow on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). Crafted POST requests to an unspecified URL result in DoS, interrupting the HTTP service (used to login to the web UI of a router) for 1 to 2 seconds. plural Tenda Router (FH1202/F1202/F1200) Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaFH1202, F1202 and F1200 are all wireless router products of Tenda",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9139",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "id": "VAR-201705-3847",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          }
        ],
        "trust": 0.99994304
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:32:12.587000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Overview-Tenda-All For Better NetWorking",
            "trust": 0.8,
            "url": "http://www.tendacn.com/en/2017.html"
          },
          {
            "title": "Patch for TendaFH1202/F1202 and F1200 Router Stack Buffer Overflow Vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/94528"
          },
          {
            "title": "Tenda FH1202 , F1202  and F1200 Repair measures for router buffer error vulnerability",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70407"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://www.tendacn.com/en/2017.html"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9139"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9139"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-31T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "date": "2017-05-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "date": "2017-06-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "date": "2017-05-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "date": "2017-05-21T22:29:00.210000",
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-31T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-07750"
          },
          {
            "date": "2017-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117342"
          },
          {
            "date": "2017-06-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          },
          {
            "date": "2017-05-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9139"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "specific network environment",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Tenda Router buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004378"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer overflow",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-915"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202404-0329

    Vulnerability from variot - Updated: 2025-01-25 22:57

    A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda F1202 is a network device used for network connection and data transmission in homes and small businesses.

    There is a stack buffer overflow vulnerability in the fromNatlimit function of the /goform/Natlimit file in Tenda F1202 1.2.0.20(408) version. An attacker can exploit this vulnerability to usurp code execution control by remotely manipulating the page parameter

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0329",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "cve": "CVE-2024-3875",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-3875",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017190",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-20787",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-3875",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017190",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-3875",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-3875",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017190",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-20787",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda F1202 is a network device used for network connection and data transmission in homes and small businesses. \n\nThere is a stack buffer overflow vulnerability in the fromNatlimit function of the /goform/Natlimit file in Tenda F1202 1.2.0.20(408) version. An attacker can exploit this vulnerability to usurp code execution control by remotely manipulating the page parameter",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-3875",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "260909",
            "trust": 1.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "id": "VAR-202404-0329",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          }
        ]
      },
      "last_update_date": "2025-01-25T22:57:35.834000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromnatlimit.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.312817"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?id.260909"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.260909"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3875"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-04-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "date": "2025-01-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "date": "2024-04-16T18:15:14.397000",
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-20787"
          },
          {
            "date": "2025-01-22T07:42:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          },
          {
            "date": "2025-01-21T16:44:42.840000",
            "db": "NVD",
            "id": "CVE-2024-3875"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017190"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0096

    Vulnerability from variot - Updated: 2025-01-25 22:48

    A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    There is a stack buffer overflow vulnerability in the fromqossetting function of Tenda F1202, which can be exploited by attackers to overflow the buffer and execute arbitrary code on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0096",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "cve": "CVE-2024-3877",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-3877",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017184",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-24534",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-3877",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017184",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-3877",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-3877",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017184",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-24534",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThere is a stack buffer overflow vulnerability in the fromqossetting function of Tenda F1202, which can be exploited by attackers to overflow the buffer and execute arbitrary code on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-3877",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "260911",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "id": "VAR-202404-0096",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          }
        ]
      },
      "last_update_date": "2025-01-25T22:48:26.519000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromqossetting.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.260911"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.312820"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3877"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.260911"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "date": "2025-01-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "date": "2024-04-16T19:15:07.667000",
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-24534"
          },
          {
            "date": "2025-01-22T07:35:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          },
          {
            "date": "2025-01-21T16:34:51.410000",
            "db": "NVD",
            "id": "CVE-2024-3877"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017184"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0182

    Vulnerability from variot - Updated: 2025-01-25 22:48

    A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    There is a stack buffer overflow vulnerability in the fromVirtualSer function of Tenda F1202, which can be exploited by attackers to overflow the buffer and execute arbitrary code on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0182",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "tenda technology co.,ltd. f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "cve": "CVE-2024-3876",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-3876",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017155",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-24532",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-3876",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017155",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-3876",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-3876",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017155",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-24532",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThere is a stack buffer overflow vulnerability in the fromVirtualSer function of Tenda F1202, which can be exploited by attackers to overflow the buffer and execute arbitrary code on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-3876",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "260910",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "id": "VAR-202404-0182",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          }
        ]
      },
      "last_update_date": "2025-01-25T22:48:26.495000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromvirtualser.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.260910"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.312818"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3876"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.260910"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "date": "2025-01-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "date": "2024-04-16T18:15:14.623000",
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-24532"
          },
          {
            "date": "2025-01-22T06:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          },
          {
            "date": "2025-01-21T16:38:31.227000",
            "db": "NVD",
            "id": "CVE-2024-3876"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017155"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0291

    Vulnerability from variot - Updated: 2025-01-25 22:38

    A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda F1202 is a network device that provides network connection and data transmission functions. The vulnerability is caused by incorrect boundary checking of the webExctypeman Filter function of the /goform/webExctypemanFilter file. An attacker can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0291",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "f1202  firmware  1.2.0.20(408)"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.2.0.20(408)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "cve": "CVE-2024-3878",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-3878",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017189",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2024-38184",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-3878",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017189",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-3878",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-3878",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017189",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-38184",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of F1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda F1202 is a network device that provides network connection and data transmission functions. The vulnerability is caused by incorrect boundary checking of the webExctypeman Filter function of the /goform/webExctypemanFilter file. An attacker can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-3878",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "260912",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "id": "VAR-202404-0291",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          }
        ]
      },
      "last_update_date": "2025-01-25T22:38:21.812000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/f/f1202/fromwebexcptypemanfilter.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.260912"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.312821"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3878"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.260912"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "date": "2025-01-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "date": "2024-04-16T19:15:07.920000",
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-38184"
          },
          {
            "date": "2025-01-22T07:41:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          },
          {
            "date": "2025-01-21T16:32:56.933000",
            "db": "NVD",
            "id": "CVE-2024-3878"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017189"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202307-0870

    Vulnerability from variot - Updated: 2025-01-07 23:26

    Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware, ac1206 firmware, FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0870",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac1206",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.23"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "ac1206",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "cve": "CVE-2023-37712",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37712",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-37712",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37712",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2023-37712",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-37712",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-532",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware, ac1206 firmware, FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37712",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "id": "VAR-202307-0870",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6766223
      },
      "last_update_date": "2025-01-07T23:26:24.820000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda AC1206 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246057"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/fromsetipbind"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37712"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37712/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-01-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "date": "2023-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "date": "2023-07-10T17:15:09.877000",
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-01-12T08:04:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          },
          {
            "date": "2023-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          },
          {
            "date": "2025-01-06T17:15:13.680000",
            "db": "NVD",
            "id": "CVE-2023-37712"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-019244"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-532"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1183

    Vulnerability from variot - Updated: 2024-08-14 15:41

    Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "ac9",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "3.0"
          },
          {
            "model": "ac5",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "ac1206",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac10",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "cve": "CVE-2023-37717",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37717",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37717",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1259",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37717"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37717",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37717",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37717"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "id": "VAR-202307-1183",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.5256526420000001
      },
      "last_update_date": "2024-08-14T15:41:40.794000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247158"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37717/"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37717"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37717"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37717"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "date": "2023-07-14T00:15:09.477000",
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37717"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          },
          {
            "date": "2023-07-21T14:31:56.167000",
            "db": "NVD",
            "id": "CVE-2023-37717"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1259"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1220

    Vulnerability from variot - Updated: 2024-08-14 15:36

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1220",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "cve": "CVE-2023-37715",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37715",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37715",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1281",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37715"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37715",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37715",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "id": "VAR-202307-1220",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.73333335
      },
      "last_update_date": "2024-08-14T15:36:53.104000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247163"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fml7protform/reprot.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37715"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37715/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37715"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37715"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "date": "2023-07-14T00:15:09.387000",
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37715"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          },
          {
            "date": "2023-07-21T14:33:22.617000",
            "db": "NVD",
            "id": "CVE-2023-37715"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1281"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1287

    Vulnerability from variot - Updated: 2024-08-14 15:31

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1287",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "4g300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "cve": "CVE-2023-37718",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37718",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37718",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1262",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37718"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37718",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37718",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37718"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "id": "VAR-202307-1287",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.7888889
      },
      "last_update_date": "2024-08-14T15:31:58.849000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247159"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafeclientfilter/report.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37718"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37718/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37718"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37718"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37718"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "date": "2023-07-14T00:15:09.523000",
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37718"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          },
          {
            "date": "2023-07-21T14:32:08.327000",
            "db": "NVD",
            "id": "CVE-2023-37718"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1262"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1202

    Vulnerability from variot - Updated: 2024-08-14 15:15

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1202",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "4g300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "cve": "CVE-2023-37722",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37722",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37722",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1276",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37722"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37722",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37722",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37722"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "id": "VAR-202307-1202",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.7888889
      },
      "last_update_date": "2024-08-14T15:15:55.510000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247162"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafeurlfilter/report.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37722"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37722/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37722"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37722"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37722"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "date": "2023-07-14T00:15:09.660000",
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37722"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          },
          {
            "date": "2023-07-21T14:26:45.147000",
            "db": "NVD",
            "id": "CVE-2023-37722"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1276"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1265

    Vulnerability from variot - Updated: 2024-08-14 15:15

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. F1202 firmware, FH1202 firmware, F1202 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1265",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "pw201a",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pw201a",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "cve": "CVE-2023-37714",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37714",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-37714",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37714",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-37714",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1257",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. F1202 firmware, FH1202 firmware, F1202 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37714"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37714",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37714",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37714"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "id": "VAR-202307-1265",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.73333335
      },
      "last_update_date": "2024-08-14T15:15:55.463000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247157"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromroutestatic/report.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37714"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37714/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37714"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37714"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37714"
          },
          {
            "date": "2024-01-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "date": "2023-07-14T00:15:09.340000",
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37714"
          },
          {
            "date": "2024-01-25T05:13:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          },
          {
            "date": "2023-07-21T14:33:06.457000",
            "db": "NVD",
            "id": "CVE-2023-37714"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-022977"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1257"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1305

    Vulnerability from variot - Updated: 2024-08-14 14:43

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1305",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "4g300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pa202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pw201a",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "cve": "CVE-2023-37721",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37721",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37721",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1264",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37721"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37721",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37721",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "id": "VAR-202307-1305",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.7888889
      },
      "last_update_date": "2024-08-14T14:43:08.587000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247160"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafemacfilter/report.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37721"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37721/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37721"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "date": "2023-07-14T00:15:09.617000",
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37721"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          },
          {
            "date": "2023-07-21T14:26:31.143000",
            "db": "NVD",
            "id": "CVE-2023-37721"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1264"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-1326

    Vulnerability from variot - Updated: 2024-08-14 14:43

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1326",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "4g300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pa202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pw201a",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "cve": "CVE-2023-37723",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37723",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37723",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1283",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37723"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37723",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37723",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37723"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "id": "VAR-202307-1326",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.7888889
      },
      "last_update_date": "2024-08-14T14:43:08.567000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247164"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromqossetting/report.md"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37723/"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37723"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37723"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37723"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37723"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "date": "2023-07-14T00:15:09.707000",
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37723"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          },
          {
            "date": "2023-07-21T14:26:54.460000",
            "db": "NVD",
            "id": "CVE-2023-37723"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1283"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202308-4082

    Vulnerability from variot - Updated: 2024-08-14 14:23

    Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware and FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4082",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.9"
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.9"
          },
          {
            "model": "f1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "cve": "CVE-2023-38939",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-38939",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-38939",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-38939",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-38939",
                "trust": 0.8,
                "value": "Critical"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware and FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-38939",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "id": "VAR-202308-4082",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.73333335
      },
      "last_update_date": "2024-08-14T14:23:50.214000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/formwrlsafeset"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38939"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-01-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "date": "2023-08-07T19:15:11.540000",
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-01-18T06:42:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          },
          {
            "date": "2023-08-09T18:06:28.010000",
            "db": "NVD",
            "id": "CVE-2023-38939"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0F1202\u00a0 firmware and \u00a0FH1202\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-021101"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202307-1352

    Vulnerability from variot - Updated: 2024-08-14 14:17

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1352",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0br"
          },
          {
            "model": "f1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.20\\(408\\)"
          },
          {
            "model": "pa202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "pw201a",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "fh1202",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.2.0.19_en"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "cve": "CVE-2023-37719",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-37719",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-37719",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202307-1274",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37719"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37719",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37719",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37719"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "id": "VAR-202307-1352",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.73333335
      },
      "last_update_date": "2024-08-14T14:17:03.005000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tenda F1202 Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247161"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromp2plistfilter/report.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37719"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37719/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37719"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37719"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37719"
          },
          {
            "date": "2023-07-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "date": "2023-07-14T00:15:09.570000",
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37719"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          },
          {
            "date": "2023-07-21T14:32:38.633000",
            "db": "NVD",
            "id": "CVE-2023-37719"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda F1202 Buffer error vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-1274"
          }
        ],
        "trust": 0.6
      }
    }