FKIE_CVE-2022-31798
Vulnerability from fkie_nvd - Published: 2022-08-25 23:15 - Updated: 2026-06-17 04:46
Severity
Summary
Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html | Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| cve@mitre.org | https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| af854a3a-2127-422b-91ae-364da2661108 | https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| nortekcontrol | emerge_e3_firmware | * | |
| nortekcontrol | emerge_e3 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1D215B46-9A29-4DA3-AF6B-7613721C12A3",
"versionEndIncluding": "0.32-07p",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nortekcontrol:emerge_e3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8EA5F43-A9AF-42F5-A6B8-018975D2FC2E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account."
},
{
"lang": "es",
"value": "Los dispositivos Nortek Linear eMerge E3-Series versi\u00f3n 0.32-07p, son vulnerables a /card_scan.php?CardFormatNo= XSS con fijaci\u00f3n de sesi\u00f3n (por medio de PHPSESSID) cuando est\u00e1n encadenados. Esto permitir\u00eda a un atacante tomar el control de una cuenta de administrador o de usuario."
}
],
"id": "CVE-2022-31798",
"lastModified": "2026-06-17T04:46:19.593",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-08-25T23:15:08.217",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-31499
Vulnerability from fkie_nvd - Published: 2022-08-25 23:15 - Updated: 2026-06-17 04:45
Severity
Summary
Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| cve@mitre.org | https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| af854a3a-2127-422b-91ae-364da2661108 | https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| nortekcontrol | emerge_e3_firmware | * | |
| nortekcontrol | emerge_e3 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A18BCC2A-E3CC-436E-BC4A-3374BB11B222",
"versionEndIncluding": "0.32-09c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nortekcontrol:emerge_e3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8EA5F43-A9AF-42F5-A6B8-018975D2FC2E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256."
},
{
"lang": "es",
"value": "Los dispositivos Nortek Linear eMerge E3-Series versiones anteriores a 0.32-08f, permiten a un atacante no autenticado inyectar comandos del sistema operativo por medio de ReaderNo. NOTA: este problema se presenta debido a una correcci\u00f3n incompleta de CVE-2019-7256."
}
],
"id": "CVE-2022-31499",
"lastModified": "2026-06-17T04:45:34.253",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-08-25T23:15:08.177",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-31269
Vulnerability from fkie_nvd - Published: 2022-08-25 22:15 - Updated: 2026-06-17 04:45
Severity
Summary
Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building's doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| cve@mitre.org | https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.nortekcontrol.com/access-control/ | Product | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://eg.linkedin.com/in/omar-1-hashem | Not Applicable | |
| af854a3a-2127-422b-91ae-364da2661108 | https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.nortekcontrol.com/access-control/ | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| nortekcontrol | emerge_e3_firmware | * | |
| nortekcontrol | emerge_e3 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A18BCC2A-E3CC-436E-BC4A-3374BB11B222",
"versionEndIncluding": "0.32-09c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nortekcontrol:emerge_e3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8EA5F43-A9AF-42F5-A6B8-018975D2FC2E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building\u0027s doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)"
},
{
"lang": "es",
"value": "Los dispositivos Nortek Linear eMerge E3-Series versiones hasta 0.32-09c, colocan credenciales de administrador en /test.txt que permiten a un atacante abrir las puertas de un edificio. (Esto ocurre en situaciones en las que han sido cambiadas las credenciales predeterminadas CVE-2019-7271)."
}
],
"id": "CVE-2022-31269",
"lastModified": "2026-06-17T04:45:15.827",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-08-25T22:15:08.547",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.nortekcontrol.com/access-control/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-5439
Vulnerability from fkie_nvd - Published: 2018-02-19 18:29 - Updated: 2026-06-17 02:00
Severity
Summary
A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| nortekcontrol | emerge_e3_firmware | * | |
| nortekcontrol | emerge_e3 | - |
{
"affected": [
{
"affectedData": [
{
"product": "Nortek Linear eMerge E3 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Nortek Linear eMerge E3 Series"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0C85E083-7741-4FFE-9912-902F623406DA",
"versionEndIncluding": "0.32-07e",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nortekcontrol:emerge_e3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8EA5F43-A9AF-42F5-A6B8-018975D2FC2E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de inyecci\u00f3n de comandos en Nortek Linear eMerge E3 series en versiones V0.32-07e y anteriores. Un atacante remoto podr\u00eda ejecutar c\u00f3digo arbitrario en un sistema objetivo con privilegios elevados."
}
],
"id": "CVE-2018-5439",
"lastModified": "2026-06-17T02:00:19.340",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-02-19T18:29:00.210",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-9441 (GCVE-0-2024-9441)
Vulnerability from nvd – Published: 2024-10-02 18:50 – Updated: 2024-10-02 19:08
VLAI
EPSS
VEX
Title
Linear eMerge e3-Series Forgot Password Command Injection
Summary
The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-02 19:05 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://ssd-disclosure.com/ssd-advisory-nortek-li… | vendor-advisoryexploit |
| https://vulncheck.com/advisories/linear-emerge-fo… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Linear | eMerge e3-Series |
Affected:
0 , ≤ 1.00-07
(custom)
|
|
| nortekcontrol | emerge_e3_firmware |
Affected:
0 , ≤ 1.00-07
(custom)
cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "emerge_e3_firmware",
"vendor": "nortekcontrol",
"versions": [
{
"lessThanOrEqual": "1.00-07",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9441",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-02T19:05:04.240743Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T19:08:03.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "eMerge e3-Series",
"vendor": "Linear",
"versions": [
{
"lessThanOrEqual": "1.00-07",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP.\u003cbr\u003e"
}
],
"value": "The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T18:50:10.938Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory",
"exploit"
],
"url": "https://ssd-disclosure.com/ssd-advisory-nortek-linear-emerge-e3-pre-auth-rce/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/linear-emerge-forgot-password"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Linear eMerge e3-Series Forgot Password Command Injection",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-9441",
"datePublished": "2024-10-02T18:50:10.938Z",
"dateReserved": "2024-10-02T17:45:57.005Z",
"dateUpdated": "2024-10-02T19:08:03.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31798 (GCVE-0-2022-31798)
Vulnerability from nvd – Published: 2022-08-25 22:15 – Updated: 2024-08-03 07:26
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| http://packetstormsecurity.com/files/167992/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/bccdcec70ab… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:17:26.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31798",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"name": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31798",
"datePublished": "2022-08-25T22:15:45.000Z",
"dateReserved": "2022-05-29T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:26:01.358Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31499 (GCVE-0-2022-31499)
Vulnerability from nvd – Published: 2022-08-25 22:09 – Updated: 2024-08-03 07:19
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| http://packetstormsecurity.com/files/167991/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/5f0c6f13940… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:19:06.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:11:40.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"name": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31499",
"datePublished": "2022-08-25T22:09:38.000Z",
"dateReserved": "2022-05-23T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:19:06.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31269 (GCVE-0-2022-31269)
Vulnerability from nvd – Published: 2022-08-25 21:59 – Updated: 2024-08-03 07:11
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building's doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| https://www.nortekcontrol.com/access-control/ | x_refsource_MISC |
| http://packetstormsecurity.com/files/167990/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/71ec9223e90… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:11:39.944Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building\u0027s doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:02:26.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31269",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building\u0027s doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "https://www.nortekcontrol.com/access-control/",
"refsource": "MISC",
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"name": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"name": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31269",
"datePublished": "2022-08-25T21:59:52.000Z",
"dateReserved": "2022-05-21T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:11:39.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5439 (GCVE-0-2018-5439)
Vulnerability from nvd – Published: 2018-02-19 18:00 – Updated: 2024-08-05 05:33
VLAI
EPSS
VEX
Summary
A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges.
Severity
No CVSS data available.
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Nortek Linear eMerge E3 Series |
Affected:
Nortek Linear eMerge E3 Series
|
Date Public
2018-02-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:33:44.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Nortek Linear eMerge E3 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Nortek Linear eMerge E3 Series"
}
]
}
],
"datePublic": "2018-02-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-02-19T17:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2018-5439",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Nortek Linear eMerge E3 Series",
"version": {
"version_data": [
{
"version_value": "Nortek Linear eMerge E3 Series"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-5439",
"datePublished": "2018-02-19T18:00:00.000Z",
"dateReserved": "2018-01-12T00:00:00.000Z",
"dateUpdated": "2024-08-05T05:33:44.375Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9441 (GCVE-0-2024-9441)
Vulnerability from cvelistv5 – Published: 2024-10-02 18:50 – Updated: 2024-10-02 19:08
VLAI
EPSS
VEX
Title
Linear eMerge e3-Series Forgot Password Command Injection
Summary
The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-02 19:05 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://ssd-disclosure.com/ssd-advisory-nortek-li… | vendor-advisoryexploit |
| https://vulncheck.com/advisories/linear-emerge-fo… | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Linear | eMerge e3-Series |
Affected:
0 , ≤ 1.00-07
(custom)
|
|
| nortekcontrol | emerge_e3_firmware |
Affected:
0 , ≤ 1.00-07
(custom)
cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:nortekcontrol:emerge_e3_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "emerge_e3_firmware",
"vendor": "nortekcontrol",
"versions": [
{
"lessThanOrEqual": "1.00-07",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9441",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-02T19:05:04.240743Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T19:08:03.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "eMerge e3-Series",
"vendor": "Linear",
"versions": [
{
"lessThanOrEqual": "1.00-07",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP.\u003cbr\u003e"
}
],
"value": "The Linear eMerge e3-Series through version 1.00-07 is vulnerable to an OS command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary OS commands via the login_id parameter when invoking the forgot_password functionality over HTTP."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T18:50:10.938Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory",
"exploit"
],
"url": "https://ssd-disclosure.com/ssd-advisory-nortek-linear-emerge-e3-pre-auth-rce/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/linear-emerge-forgot-password"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Linear eMerge e3-Series Forgot Password Command Injection",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-9441",
"datePublished": "2024-10-02T18:50:10.938Z",
"dateReserved": "2024-10-02T17:45:57.005Z",
"dateUpdated": "2024-10-02T19:08:03.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31798 (GCVE-0-2022-31798)
Vulnerability from cvelistv5 – Published: 2022-08-25 22:15 – Updated: 2024-08-03 07:26
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| http://packetstormsecurity.com/files/167992/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/bccdcec70ab… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:17:26.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31798",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series 0.32-07p devices are vulnerable to /card_scan.php?CardFormatNo= XSS with session fixation (via PHPSESSID) when they are chained together. This would allow an attacker to take over an admin account or a user account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167992/Nortek-Linear-eMerge-E3-Series-Account-Takeover.html"
},
{
"name": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/bccdcec70ab7e8f00519d56ea2e3fd79"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31798",
"datePublished": "2022-08-25T22:15:45.000Z",
"dateReserved": "2022-05-29T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:26:01.358Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31499 (GCVE-0-2022-31499)
Vulnerability from cvelistv5 – Published: 2022-08-25 22:09 – Updated: 2024-08-03 07:19
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| http://packetstormsecurity.com/files/167991/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/5f0c6f13940… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:19:06.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:11:40.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series devices before 0.32-08f allow an unauthenticated attacker to inject OS commands via ReaderNo. NOTE: this issue exists because of an incomplete fix for CVE-2019-7256."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167991/Nortek-Linear-eMerge-E3-Series-Command-Injection.html"
},
{
"name": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/5f0c6f1394099b555740fdc5c7651ee2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31499",
"datePublished": "2022-08-25T22:09:38.000Z",
"dateReserved": "2022-05-23T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:19:06.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31269 (GCVE-0-2022-31269)
Vulnerability from cvelistv5 – Published: 2022-08-25 21:59 – Updated: 2024-08-03 07:11
VLAI
EPSS
VEX
Summary
Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building's doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://eg.linkedin.com/in/omar-1-hashem | x_refsource_MISC |
| https://www.nortekcontrol.com/access-control/ | x_refsource_MISC |
| http://packetstormsecurity.com/files/167990/Norte… | x_refsource_MISC |
| https://gist.github.com/omarhashem123/71ec9223e90… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:11:39.944Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building\u0027s doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-25T22:02:26.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-31269",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Nortek Linear eMerge E3-Series devices through 0.32-09c place admin credentials in /test.txt that allow an attacker to open a building\u0027s doors. (This occurs in situations where the CVE-2019-7271 default credentials have been changed.)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://eg.linkedin.com/in/omar-1-hashem",
"refsource": "MISC",
"url": "https://eg.linkedin.com/in/omar-1-hashem"
},
{
"name": "https://www.nortekcontrol.com/access-control/",
"refsource": "MISC",
"url": "https://www.nortekcontrol.com/access-control/"
},
{
"name": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167990/Nortek-Linear-eMerge-E3-Series-Credential-Disclosure.html"
},
{
"name": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c",
"refsource": "MISC",
"url": "https://gist.github.com/omarhashem123/71ec9223e90ea76a76096d777d9b945c"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-31269",
"datePublished": "2022-08-25T21:59:52.000Z",
"dateReserved": "2022-05-21T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:11:39.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5439 (GCVE-0-2018-5439)
Vulnerability from cvelistv5 – Published: 2018-02-19 18:00 – Updated: 2024-08-05 05:33
VLAI
EPSS
VEX
Summary
A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges.
Severity
No CVSS data available.
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Nortek Linear eMerge E3 Series |
Affected:
Nortek Linear eMerge E3 Series
|
Date Public
2018-02-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:33:44.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Nortek Linear eMerge E3 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Nortek Linear eMerge E3 Series"
}
]
}
],
"datePublic": "2018-02-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-02-19T17:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2018-5439",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Nortek Linear eMerge E3 Series",
"version": {
"version_data": [
{
"version_value": "Nortek Linear eMerge E3 Series"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-5439",
"datePublished": "2018-02-19T18:00:00.000Z",
"dateReserved": "2018-01-12T00:00:00.000Z",
"dateUpdated": "2024-08-05T05:33:44.375Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}