Search criteria
10 vulnerabilities found for emc_unisphere_for_powermax by dell
CVE-2021-21548 (GCVE-0-2021-21548)
Vulnerability from nvd – Published: 2023-03-17 05:07 – Updated: 2025-02-26 14:56
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim's traffic to view or modify a victim’s data in transit.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax, Dell EMC Unisphere for PowerMax Virtual Appliance , PowerMax OS |
Affected:
Versions before 9.1.0.27
Affected: 5978 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.985Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000189606/dsa-2021-134-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-and-dell-emc-powermax-embedded-management-security-update-for-multiple-third-party-component-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-21548",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T14:54:45.735135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T14:56:10.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax, Dell EMC Unisphere for PowerMax Virtual Appliance , PowerMax OS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions before 9.1.0.27"
},
{
"status": "affected",
"version": "5978"
}
]
}
],
"datePublic": "2021-07-22T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit.\u003c/span\u003e\n\n"
}
],
"value": "\nDell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-17T05:07:42.867Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000189606/dsa-2021-134-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-and-dell-emc-powermax-embedded-management-security-update-for-multiple-third-party-component-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21548",
"datePublished": "2023-03-17T05:07:42.867Z",
"dateReserved": "2021-01-04T15:38:42.784Z",
"dateUpdated": "2025-02-26T14:56:10.218Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45103 (GCVE-0-2022-45103)
Vulnerability from nvd – Published: 2023-01-18 14:31 – Updated: 2025-04-03 18:04
VLAI?
Summary
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.
Severity ?
6.5 (Medium)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax vApp |
Affected:
9.2.3.x
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.587Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45103",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:10:27.465411Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T18:04:23.945Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax vApp",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "9.2.3.x"
}
]
}
],
"datePublic": "2023-01-04T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T14:31:56.582Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-45103",
"datePublished": "2023-01-18T14:31:56.582Z",
"dateReserved": "2022-11-09T15:48:33.040Z",
"dateUpdated": "2025-04-03T18:04:23.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5367 (GCVE-0-2020-5367)
Vulnerability from nvd – Published: 2020-06-23 20:00 – Updated: 2024-09-16 17:58
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim's traffic to view or modify a victim's data in transit.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax, Unisphere for PowerMax Virtual Appliance, PowerMax OS |
Affected:
9.1.0.17
Affected: 5978 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000153935/dsa-2020-065-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-and-dell-emc-powermax-embedded-management-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax, Unisphere for PowerMax Virtual Appliance, PowerMax OS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "9.1.0.17"
},
{
"status": "affected",
"version": "5978"
}
]
}
],
"datePublic": "2021-04-08T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u0027s data in transit. \u003c/span\u003e"
}
],
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u0027s data in transit."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-17T05:15:29.817Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000153935/dsa-2020-065-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-and-dell-emc-powermax-embedded-management-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-06-18",
"ID": "CVE-2020-5367",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.17"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.4,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-295: Improper Certificate Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5367",
"datePublished": "2020-06-23T20:00:17.667661Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-16T17:58:28.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5345 (GCVE-0-2020-5345)
Vulnerability from nvd – Published: 2020-06-23 20:00 – Updated: 2024-09-17 01:51
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics.
Severity ?
6.4 (Medium)
CWE
- CWE-602 - Client-Side Enforcement of Server-Side Security
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
unspecified , < 9.1.0.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.278Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.1.0.17",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-06-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602: Client-Side Enforcement of Server-Side Security",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-23T20:00:17",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-06-18",
"ID": "CVE-2020-5345",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.17"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.4,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-602: Client-Side Enforcement of Server-Side Security"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5345",
"datePublished": "2020-06-23T20:00:17.264990Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-17T01:51:14.465Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18588 (GCVE-0-2019-18588)
Vulnerability from nvd – Published: 2020-01-10 18:20 – Updated: 2024-09-17 02:21
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users' sessions.
Severity ?
9 (Critical)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
unspecified , < 9.1.0.9 and 9.0.2.16
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:54:14.490Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.1.0.9 and 9.0.2.16",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-12-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-10T18:20:11",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-12-12",
"ID": "CVE-2019-18588",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.9 and 9.0.2.16"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
}
]
},
"impact": {
"cvss": {
"baseScore": 9,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-18588",
"datePublished": "2020-01-10T18:20:11.404654Z",
"dateReserved": "2019-10-29T00:00:00",
"dateUpdated": "2024-09-17T02:21:01.089Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21548 (GCVE-0-2021-21548)
Vulnerability from cvelistv5 – Published: 2023-03-17 05:07 – Updated: 2025-02-26 14:56
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim's traffic to view or modify a victim’s data in transit.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax, Dell EMC Unisphere for PowerMax Virtual Appliance , PowerMax OS |
Affected:
Versions before 9.1.0.27
Affected: 5978 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.985Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000189606/dsa-2021-134-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-and-dell-emc-powermax-embedded-management-security-update-for-multiple-third-party-component-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-21548",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T14:54:45.735135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T14:56:10.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax, Dell EMC Unisphere for PowerMax Virtual Appliance , PowerMax OS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions before 9.1.0.27"
},
{
"status": "affected",
"version": "5978"
}
]
}
],
"datePublic": "2021-07-22T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit.\u003c/span\u003e\n\n"
}
],
"value": "\nDell EMC Unisphere for PowerMax versions before 9.1.0.27, Dell EMC Unisphere for PowerMax Virtual Appliance versions before 9.1.0.27, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-17T05:07:42.867Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000189606/dsa-2021-134-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-and-dell-emc-powermax-embedded-management-security-update-for-multiple-third-party-component-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21548",
"datePublished": "2023-03-17T05:07:42.867Z",
"dateReserved": "2021-01-04T15:38:42.784Z",
"dateUpdated": "2025-02-26T14:56:10.218Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45103 (GCVE-0-2022-45103)
Vulnerability from cvelistv5 – Published: 2023-01-18 14:31 – Updated: 2025-04-03 18:04
VLAI?
Summary
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.
Severity ?
6.5 (Medium)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax vApp |
Affected:
9.2.3.x
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.587Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45103",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:10:27.465411Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T18:04:23.945Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax vApp",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "9.2.3.x"
}
]
}
],
"datePublic": "2023-01-04T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain an information disclosure vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to read arbitrary files on the underlying file system.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T14:31:56.582Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-45103",
"datePublished": "2023-01-18T14:31:56.582Z",
"dateReserved": "2022-11-09T15:48:33.040Z",
"dateUpdated": "2025-04-03T18:04:23.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5367 (GCVE-0-2020-5367)
Vulnerability from cvelistv5 – Published: 2020-06-23 20:00 – Updated: 2024-09-16 17:58
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim's traffic to view or modify a victim's data in transit.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax, Unisphere for PowerMax Virtual Appliance, PowerMax OS |
Affected:
9.1.0.17
Affected: 5978 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000153935/dsa-2020-065-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-and-dell-emc-powermax-embedded-management-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax, Unisphere for PowerMax Virtual Appliance, PowerMax OS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "9.1.0.17"
},
{
"status": "affected",
"version": "5978"
}
]
}
],
"datePublic": "2021-04-08T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u0027s data in transit. \u003c/span\u003e"
}
],
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u0027s data in transit."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-17T05:15:29.817Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-uk/000153935/dsa-2020-065-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-and-dell-emc-powermax-embedded-management-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-06-18",
"ID": "CVE-2020-5367",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.17"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and intercepting the victim\u0027s traffic to view or modify a victim\u2019s data in transit."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.4,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-295: Improper Certificate Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5367",
"datePublished": "2020-06-23T20:00:17.667661Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-16T17:58:28.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5345 (GCVE-0-2020-5345)
Vulnerability from cvelistv5 – Published: 2020-06-23 20:00 – Updated: 2024-09-17 01:51
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics.
Severity ?
6.4 (Medium)
CWE
- CWE-602 - Client-Side Enforcement of Server-Side Security
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
unspecified , < 9.1.0.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.278Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.1.0.17",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-06-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602: Client-Side Enforcement of Server-Side Security",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-23T20:00:17",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-06-18",
"ID": "CVE-2020-5345",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.17"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.4,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-602: Client-Side Enforcement of Server-Side Security"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5345",
"datePublished": "2020-06-23T20:00:17.264990Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-17T01:51:14.465Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18588 (GCVE-0-2019-18588)
Vulnerability from cvelistv5 – Published: 2020-01-10 18:20 – Updated: 2024-09-17 02:21
VLAI?
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users' sessions.
Severity ?
9 (Critical)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
unspecified , < 9.1.0.9 and 9.0.2.16
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:54:14.490Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.1.0.9 and 9.0.2.16",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-12-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-10T18:20:11",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-12-12",
"ID": "CVE-2019-18588",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unisphere for PowerMax",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.1.0.9 and 9.0.2.16"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
}
]
},
"impact": {
"cvss": {
"baseScore": 9,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-18588",
"datePublished": "2020-01-10T18:20:11.404654Z",
"dateReserved": "2019-10-29T00:00:00",
"dateUpdated": "2024-09-17T02:21:01.089Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}