Search criteria
2 vulnerabilities found for eds_hardware_installation_tool by rockwellautomation
CVE-2011-2530 (GCVE-0-2011-2530)
Vulnerability from nvd – Published: 2011-06-22 21:00 – Updated: 2024-09-17 01:07
VLAI?
Summary
Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:08:22.014Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/48092"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2011-06-22T21:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/48092"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-2530",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/48092"
},
{
"name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194",
"refsource": "CONFIRM",
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-2530",
"datePublished": "2011-06-22T21:00:00Z",
"dateReserved": "2011-06-22T00:00:00Z",
"dateUpdated": "2024-09-17T01:07:00.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-2530 (GCVE-0-2011-2530)
Vulnerability from cvelistv5 – Published: 2011-06-22 21:00 – Updated: 2024-09-17 01:07
VLAI?
Summary
Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:08:22.014Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/48092"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2011-06-22T21:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/48092"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-2530",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/MAPG-8G9PWX"
},
{
"name": "VU#127584",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/127584"
},
{
"name": "48092",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/48092"
},
{
"name": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194",
"refsource": "CONFIRM",
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/279194"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-2530",
"datePublished": "2011-06-22T21:00:00Z",
"dateReserved": "2011-06-22T00:00:00Z",
"dateUpdated": "2024-09-17T01:07:00.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}