Search
Find a vulnerability
Search criteria
8 vulnerabilities found for edge_insights_for_industrial by intel
CVE-2022-25966 (GCVE-0-2022-25966)
Vulnerability from nvd – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:23
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:36.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-25966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:29:57.510701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:23:05.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:09.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-25966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-25966",
"datePublished": "2022-08-18T19:47:09.000Z",
"dateReserved": "2022-03-02T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:23:05.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-22730 (GCVE-0-2022-22730)
Vulnerability from nvd – Published: 2022-08-18 19:44 – Updated: 2025-05-05 16:29
VLAI
EPSS
VEX
Summary
Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- CWE-287 - Improper Authentication
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.106Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-22730",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:27:31.545763Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:29:50.904Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:44:53.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-22730",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-22730",
"datePublished": "2022-08-18T19:44:53.000Z",
"dateReserved": "2022-02-03T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:29:50.904Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21152 (GCVE-0-2022-21152)
Vulnerability from nvd – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:38
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access.
Severity
5.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- information disclosure
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.004Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-21152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:20:00.392319Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:38:00.171Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:35.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-21152",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21152",
"datePublished": "2022-08-18T19:47:35.000Z",
"dateReserved": "2021-12-09T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:38:00.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21148 (GCVE-0-2022-21148)
Vulnerability from nvd – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:38
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.004Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-21148",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:29:55.618273Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:38:21.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:20.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-21148",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21148",
"datePublished": "2022-08-18T19:47:20.000Z",
"dateReserved": "2021-12-09T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:38:21.656Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21152 (GCVE-0-2022-21152)
Vulnerability from cvelistv5 – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:38
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access.
Severity
5.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- information disclosure
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.004Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-21152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:20:00.392319Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:38:00.171Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:35.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-21152",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable information disclosure via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21152",
"datePublished": "2022-08-18T19:47:35.000Z",
"dateReserved": "2021-12-09T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:38:00.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21148 (GCVE-0-2022-21148)
Vulnerability from cvelistv5 – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:38
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.004Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-21148",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:29:55.618273Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:38:21.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:20.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-21148",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21148",
"datePublished": "2022-08-18T19:47:20.000Z",
"dateReserved": "2021-12-09T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:38:21.656Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25966 (GCVE-0-2022-25966)
Vulnerability from cvelistv5 – Published: 2022-08-18 19:47 – Updated: 2025-05-05 16:23
VLAI
EPSS
VEX
Summary
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- NVD-CWE-Other
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:36.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-25966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:29:57.510701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NVD-CWE-Other",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:23:05.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:47:09.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-25966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-25966",
"datePublished": "2022-08-18T19:47:09.000Z",
"dateReserved": "2022-03-02T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:23:05.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-22730 (GCVE-0-2022-22730)
Vulnerability from cvelistv5 – Published: 2022-08-18 19:44 – Updated: 2025-05-05 16:29
VLAI
EPSS
VEX
Summary
Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- escalation of privilege
- CWE-287 - Improper Authentication
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.intel.com/content/www/us/en/security-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Edge Insights for Industrial software |
Affected:
before version 2.6.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.106Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-22730",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:27:31.545763Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:29:50.904Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Edge Insights for Industrial software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-18T19:44:53.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2022-22730",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Edge Insights for Industrial software",
"version": {
"version_data": [
{
"version_value": "before version 2.6.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper authentication in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an unauthenticated user to potentially enable escalation of privilege via network access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-22730",
"datePublished": "2022-08-18T19:44:53.000Z",
"dateReserved": "2022-02-03T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:29:50.904Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}