Search
Find a vulnerability
Search criteria
6 vulnerabilities found for ds-a80316s_firmware by hikvision
CVE-2023-28808 (GCVE-0-2023-28808)
Vulnerability from nvd – Published: 2023-04-11 00:00 – Updated: 2025-02-07 19:35
VLAI
EPSS
VEX
Summary
Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-8
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2023-04-11 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28808",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T19:35:09.080119Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T19:35:13.163Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-8",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4 ",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Souvik Kandar, Arko Dhar"
}
],
"datePublic": "2023-04-11T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/notice/security-notification-23-4-10/Fixing-Security-Vulnerability-of-Hybrid-SAN-230407.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2023-28808",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-23T00:00:00.000Z",
"dateUpdated": "2025-02-07T19:35:13.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28172 (GCVE-0-2022-28172)
Vulnerability from nvd – Published: 2022-06-27 17:50 – Updated: 2024-09-17 01:10
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device.
Severity
6.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-31T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28172",
"datePublished": "2022-06-27T17:50:40.922Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:46.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28171 (GCVE-0-2022-28171)
Vulnerability from nvd – Published: 2022-06-27 17:48 – Updated: 2024-09-16 17:03
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device.
Severity
7.5 (High)
CWE
- CWE-78 - OS Command Injection
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-20T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28171",
"datePublished": "2022-06-27T17:48:51.569Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:03:49.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28808 (GCVE-0-2023-28808)
Vulnerability from cvelistv5 – Published: 2023-04-11 00:00 – Updated: 2025-02-07 19:35
VLAI
EPSS
VEX
Summary
Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-8
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2023-04-11 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28808",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T19:35:09.080119Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T19:35:13.163Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-8",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4 ",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Souvik Kandar, Arko Dhar"
}
],
"datePublic": "2023-04-11T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-cluster-stor/"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/notice/security-notification-23-4-10/Fixing-Security-Vulnerability-of-Hybrid-SAN-230407.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2023-28808",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-03-23T00:00:00.000Z",
"dateUpdated": "2025-02-07T19:35:13.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28172 (GCVE-0-2022-28172)
Vulnerability from cvelistv5 – Published: 2022-06-27 17:50 – Updated: 2024-09-17 01:10
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device.
Severity
6.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-31T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28172",
"datePublished": "2022-06-27T17:50:40.922Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:46.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28171 (GCVE-0-2022-28171)
Vulnerability from cvelistv5 – Published: 2022-06-27 17:48 – Updated: 2024-09-16 17:03
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device.
Severity
7.5 (High)
CWE
- CWE-78 - OS Command Injection
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-20T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28171",
"datePublished": "2022-06-27T17:48:51.569Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:03:49.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}