Search

Find a vulnerability

Search criteria

    5 vulnerabilities found for dpc3941t by cisco

    VAR-201707-1025

    Vulnerability from variot - Updated: 2025-04-20 23:42

    The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices allows remote attackers to execute arbitrary code via a specific (but unstated) exposed service. NOTE: the scope of this CVE does NOT include the concept of "Unnecessary Services" in general; the scope is only a single service that is unnecessarily exposed, leading to remote code execution. The details of that service might be disclosed at a later date. plural Cisco DPC Products and Arris TG1682G Contains vulnerabilities related to security features.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Cisco DPC3939 (XB3) and so on are Cisco's wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a set of firmware developed by Comcast, Inc., which runs on gateways and modem devices. A remote attacker can exploit this vulnerability to execute arbitrary code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1025",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421733-160420a-cmcst"
          },
          {
            "model": "dpc3941t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939b",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939b-v303r204217-150321a-cmcst"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "10.0.132.sip.pc20.ct"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "tg1682_2.2p7s2_prod_sey"
          },
          {
            "model": "tg1682g",
            "scope": null,
            "trust": 0.8,
            "vendor": "arris group",
            "version": null
          },
          {
            "model": "dpc3939 wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939b business wireless gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:arris:tg1682g_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939_wireless_residential_voice_gateway_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939b_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3941t_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          }
        ]
      },
      "cve": "CVE-2017-9521",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2017-9521",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-19463",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-117724",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2017-9521",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-9521",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9521",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9521",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-19463",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-276",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117724",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA\u0026DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices allows remote attackers to execute arbitrary code via a specific (but unstated) exposed service. NOTE: the scope of this CVE does NOT include the concept of \"Unnecessary Services\" in general; the scope is only a single service that is unnecessarily exposed, leading to remote code execution. The details of that service might be disclosed at a later date. plural Cisco DPC Products and Arris TG1682G Contains vulnerabilities related to security features.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Cisco DPC3939 (XB3) and so on are Cisco\u0027s wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a set of firmware developed by Comcast, Inc., which runs on gateways and modem devices. A remote attacker can exploit this vulnerability to execute arbitrary code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9521",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "id": "VAR-201707-1025",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          }
        ],
        "trust": 1.304761895
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:42:58.622000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "TG1682G",
            "trust": 0.8,
            "url": "http://arris.force.com/consumers/ConsumerProductDetail?p=a0ha000000TnNmSAAV\u0026c=Touchstone%20Modems%20and%20Gateways"
          },
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "https://www.cisco.com/c/ja_jp/index.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-254",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://github.com/bastilleresearch/cabletap/blob/master/doc/advisories/bastille-32.unnecessary-services.txt"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9521"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9521"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "date": "2017-07-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "date": "2017-06-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "date": "2017-07-31T03:29:00.973000",
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-19463"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117724"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9521"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Cisco DPC Products and  Arris TG1682G Vulnerabilities related to security functions",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006594"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "lack of information",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-276"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201707-1017

    Vulnerability from variot - Updated: 2025-04-20 23:42

    The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not set the secure flag for cookies in an https session to an administration application, which makes it easier for remote attackers to capture these cookies by intercepting their transmission within an http session. plural Cisco DPC Products and Arris TG1682G Contains an information disclosure vulnerability.Information may be obtained. Cisco DPC3939 (XB3) and so on are Cisco's wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. There are security holes in the Comcast firmware in several products. A remote attacker can exploit this vulnerability to take a screenshot of a cookie

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1017",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dpc3941t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939b",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939b-v303r204217-150321a-cmcst"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421733-160420a-cmcst"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "10.0.132.sip.pc20.ct"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "tg1682_2.2p7s2_prod_sey"
          },
          {
            "model": "tg1682g",
            "scope": null,
            "trust": 0.8,
            "vendor": "arris group",
            "version": null
          },
          {
            "model": "dpc3939 wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939b business wireless gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421746-170221a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t dpc3941 2.5s3 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939b dpc3939b-v303r204217-150321a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421733-160420a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "tg1682g emta\u0026docsis 10.0.132.sip.pc20.ct",
            "scope": null,
            "trust": 0.6,
            "vendor": "arris",
            "version": null
          },
          {
            "model": "tg1682g tg1682 2.2p7s2 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "arris",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:arris:tg1682g_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939_wireless_residential_voice_gateway_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939b_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3941t_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          }
        ]
      },
      "cve": "CVE-2017-9491",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2017-9491",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-26626",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-117694",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2017-9491",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.3,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2017-9491",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9491",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9491",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-26626",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-226",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117694",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA\u0026DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not set the secure flag for cookies in an https session to an administration application, which makes it easier for remote attackers to capture these cookies by intercepting their transmission within an http session. plural Cisco DPC Products and Arris TG1682G Contains an information disclosure vulnerability.Information may be obtained. Cisco DPC3939 (XB3) and so on are Cisco\u0027s wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. There are security holes in the Comcast firmware in several products. A remote attacker can exploit this vulnerability to take a screenshot of a cookie",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9491",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "id": "VAR-201707-1017",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          }
        ],
        "trust": 1.5870748271428572
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:42:11.161000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "TG1682G",
            "trust": 0.8,
            "url": "http://arris.force.com/consumers/ConsumerProductDetail?p=a0ha000000TnNmSAAV\u0026c=Touchstone%20Modems%20and%20Gateways"
          },
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "https://www.cisco.com/c/ja_jp/index.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://github.com/bastilleresearch/cabletap/blob/master/doc/advisories/bastille-35.improper-cookie-flags.txt"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9491"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9491"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "date": "2017-07-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "date": "2017-06-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "date": "2017-07-31T03:29:00.707000",
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26626"
          },
          {
            "date": "2017-08-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117694"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          },
          {
            "date": "2021-09-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9491"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Cisco DPC Products and  Arris TG1682G Vulnerable to information disclosure",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006592"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-226"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201707-1013

    Vulnerability from variot - Updated: 2025-04-20 23:32

    The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to discover a WAN IPv6 IP address by leveraging knowledge of the CM MAC address. Cisco DPC3939 and DPC3941T Contains an information disclosure vulnerability.Information may be obtained. The Cisco DPC3939 and DPC3941T are both Cisco Wireless Voice Gateway products. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. A security vulnerability exists in the Cisco DPC3939 using the dpc3939-P20-18-v303r20421746-170221a-CMCST firmware and the Comcast firmware in the DPC3941T using the DPC3941_2.5s3_PROD_sey firmware. A remote attacker could exploit this vulnerability to obtain a WANIPv6 IP address

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1013",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dpc3941t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3939 wireless residential voice gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3941t wireless residential voice gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421746-170221a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t dpc3941 2.5s3 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939_wireless_residential_voice_gateway_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3941t_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          }
        ]
      },
      "cve": "CVE-2017-9487",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2017-9487",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2017-26623",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-117690",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "id": "CVE-2017-9487",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9487",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9487",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-26623",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-230",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117690",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to discover a WAN IPv6 IP address by leveraging knowledge of the CM MAC address. Cisco DPC3939 and DPC3941T Contains an information disclosure vulnerability.Information may be obtained. The Cisco DPC3939 and DPC3941T are both Cisco Wireless Voice Gateway products. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. A security vulnerability exists in the Cisco DPC3939 using the dpc3939-P20-18-v303r20421746-170221a-CMCST firmware and the Comcast firmware in the DPC3941T using the DPC3941_2.5s3_PROD_sey firmware. A remote attacker could exploit this vulnerability to obtain a WANIPv6 IP address",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9487",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "id": "VAR-201707-1013",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          }
        ],
        "trust": 1.521428565
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:32:11.011000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "https://www.cisco.com/c/ja_jp/index.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://github.com/bastilleresearch/cabletap/blob/master/doc/advisories/bastille-30.wan0-ipv6-cm-mac.txt"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9487"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9487"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "date": "2017-07-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "date": "2017-08-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "date": "2017-06-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "date": "2017-07-31T03:29:00.597000",
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26623"
          },
          {
            "date": "2017-08-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117690"
          },
          {
            "date": "2017-08-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          },
          {
            "date": "2017-11-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9487"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cisco DPC3939 and  DPC3941T Vulnerable to information disclosure",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006524"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-230"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201707-1018

    Vulnerability from variot - Updated: 2025-04-20 23:27

    The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not include the HTTPOnly flag in a Set-Cookie header for administration applications, which makes it easier for remote attackers to obtain potentially sensitive information via script access to cookies. plural Cisco DPC Products and Arris TG1682G Contains an information disclosure vulnerability.Information may be obtained. Cisco DPC3939 (XB3) and so on are Cisco's wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. There are security holes in the Comcast firmware in several products. A remote attacker can exploit this vulnerability to obtain sensitive information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1018",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dpc3941t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939b",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939b-v303r204217-150321a-cmcst"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421733-160420a-cmcst"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "10.0.132.sip.pc20.ct"
          },
          {
            "model": "arris tg1682g",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "commscope",
            "version": "tg1682_2.2p7s2_prod_sey"
          },
          {
            "model": "tg1682g",
            "scope": null,
            "trust": 0.8,
            "vendor": "arris group",
            "version": null
          },
          {
            "model": "dpc3939 wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939b business wireless gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t wireless residential voice gateway",
            "scope": null,
            "trust": 0.8,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421746-170221a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t dpc3941 2.5s3 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939b dpc3939b-v303r204217-150321a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421733-160420a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "tg1682g emta\u0026docsis 10.0.132.sip.pc20.ct",
            "scope": null,
            "trust": 0.6,
            "vendor": "arris",
            "version": null
          },
          {
            "model": "tg1682g tg1682 2.2p7s2 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "arris",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:arris:tg1682g_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939_wireless_residential_voice_gateway_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939b_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3941t_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          }
        ]
      },
      "cve": "CVE-2017-9492",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2017-9492",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-26627",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-117695",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2017-9492",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-9492",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9492",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9492",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-26627",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-225",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117695",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA\u0026DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not include the HTTPOnly flag in a Set-Cookie header for administration applications, which makes it easier for remote attackers to obtain potentially sensitive information via script access to cookies. plural Cisco DPC Products and Arris TG1682G Contains an information disclosure vulnerability.Information may be obtained. Cisco DPC3939 (XB3) and so on are Cisco\u0027s wireless home voice gateway products. The ArrisTG1682G is a modem product from Arris, USA. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. There are security holes in the Comcast firmware in several products. A remote attacker can exploit this vulnerability to obtain sensitive information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9492",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "id": "VAR-201707-1018",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          }
        ],
        "trust": 1.5870748271428572
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:27:22.204000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "TG1682G",
            "trust": 0.8,
            "url": "http://arris.force.com/consumers/ConsumerProductDetail?p=a0ha000000TnNmSAAV\u0026c=Touchstone%20Modems%20and%20Gateways"
          },
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "https://www.cisco.com/c/ja_jp/index.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://github.com/bastilleresearch/cabletap/blob/master/doc/advisories/bastille-35.improper-cookie-flags.txt"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9492"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9492"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "date": "2017-07-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "date": "2017-06-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "date": "2017-07-31T03:29:00.737000",
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26627"
          },
          {
            "date": "2017-08-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117695"
          },
          {
            "date": "2017-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          },
          {
            "date": "2021-09-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9492"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Cisco DPC Products and  Arris TG1682G Vulnerable to information disclosure",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006593"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-225"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201707-1014

    Vulnerability from variot - Updated: 2025-04-20 23:26

    The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to access the web UI by establishing a session to the wan0 WAN IPv6 address and then entering unspecified hardcoded credentials. This wan0 interface cannot be accessed from the public Internet. Cisco DPC3939 and DPC3941T Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Cisco DPC3939 and DPC3941T are both Cisco Wireless Voice Gateway products. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. A security vulnerability exists in the Cisco DPC3939 using the dpc3939-P20-18-v303r20421746-170221a-CMCST firmware and the Comcast firmware in the DPC3941T using the DPC3941_2.5s3_PROD_sey firmware. A remote attacker could exploit the vulnerability to access the WebUI with a hard-coded certificate

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1014",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dpc3941t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3939 wireless residential voice gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "cisco",
            "version": "dpc3939-p20-18-v303r20421746-170221a-cmcst"
          },
          {
            "model": "dpc3941t wireless residential voice gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "cisco",
            "version": "dpc3941_2.5s3_prod_sey"
          },
          {
            "model": "dpc3939 dpc3939-p20-18-v303r20421746-170221a-cmcst",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          },
          {
            "model": "dpc3941t dpc3941 2.5s3 prod sey",
            "scope": null,
            "trust": 0.6,
            "vendor": "cisco",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3939_wireless_residential_voice_gateway_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:cisco:dpc3941t_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          }
        ]
      },
      "cve": "CVE-2017-9488",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2017-9488",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2017-26624",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "VHN-117691",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-9488",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9488",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9488",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-26624",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-229",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117691",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to access the web UI by establishing a session to the wan0 WAN IPv6 address and then entering unspecified hardcoded credentials. This wan0 interface cannot be accessed from the public Internet. Cisco DPC3939 and DPC3941T Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Cisco DPC3939 and DPC3941T are both Cisco Wireless Voice Gateway products. Comcast is a firmware developed by Comcast, Inc., which runs on devices such as gateways and modems. A security vulnerability exists in the Cisco DPC3939 using the dpc3939-P20-18-v303r20421746-170221a-CMCST firmware and the Comcast firmware in the DPC3941T using the DPC3941_2.5s3_PROD_sey firmware. A remote attacker could exploit the vulnerability to access the WebUI with a hard-coded certificate",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9488",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "id": "VAR-201707-1014",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          }
        ],
        "trust": 1.521428565
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:26:02.783000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
            "trust": 0.8,
            "url": "https://www.cisco.com/c/ja_jp/index.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://github.com/bastilleresearch/cabletap/blob/master/doc/advisories/bastille-31.stb-remote-webui.txt"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9488"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9488"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "date": "2017-07-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "date": "2017-08-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "date": "2017-06-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "date": "2017-07-31T03:29:00.613000",
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-26624"
          },
          {
            "date": "2017-08-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117691"
          },
          {
            "date": "2017-08-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          },
          {
            "date": "2017-11-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9488"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "specific network environment",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cisco DPC3939 and  DPC3941T Vulnerabilities related to the use of hard-coded credentials",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-006525"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "lack of information",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-229"
          }
        ],
        "trust": 0.6
      }
    }