Search criteria
82 vulnerabilities found for development_system by codesys
CVE-2023-3669 (GCVE-0-2023-3669)
Vulnerability from nvd – Published: 2023-08-03 11:11 – Updated: 2025-02-27 21:11
VLAI?
Title
CODESYS: Missing Brute-Force protection in CODESYS Development System
Summary
A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.
Severity ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Development System |
Affected:
3.0.0.0 , < 3.5.19.20
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-023"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:51:08.351739Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T21:11:19.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog."
}
],
"value": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:11:05.068Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-023"
}
],
"source": {
"advisory": "VDE-2023-023",
"defect": [
"CERT@VDE#64562"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Missing Brute-Force protection in CODESYS Development System",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3669",
"datePublished": "2023-08-03T11:11:05.068Z",
"dateReserved": "2023-07-14T07:42:23.825Z",
"dateUpdated": "2025-02-27T21:11:19.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Heap-based Buffer Overflow in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity ?
6.5 (Medium)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37555 (GCVE-0-2023-37555)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:51.974Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:33.660Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37555",
"datePublished": "2023-08-03T11:05:33.660Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37554 (GCVE-0-2023-37554)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37554",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:34.979Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553, CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:09.750Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37554",
"datePublished": "2023-08-03T11:05:09.750Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:09:34.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37553 (GCVE-0-2023-37553)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.602Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37553",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:16.403Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:39.061Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37553",
"datePublished": "2023-08-03T11:04:39.061Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:16.403Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37552 (GCVE-0-2023-37552)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37552",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:33.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:04.128Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37552",
"datePublished": "2023-08-03T11:04:04.128Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:33.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37551 (GCVE-0-2023-37551)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Files or Directories Accessible to External Parties in CmpApp
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Severity ?
6.5 (Medium)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37551",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:51.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:37.457Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Files or Directories Accessible to External Parties in CmpApp",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37551",
"datePublished": "2023-08-03T11:03:37.457Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:51.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37550 (GCVE-0-2023-37550)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:11
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37550",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:11:18.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:09.222Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37550",
"datePublished": "2023-08-03T11:03:09.222Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:11:18.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37549 (GCVE-0-2023-37549)
Vulnerability from nvd – Published: 2023-08-03 11:02 – Updated: 2024-10-11 18:12
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37549",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:40.613696Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:01.720Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:02:33.725Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37549",
"datePublished": "2023-08-03T11:02:33.725Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:01.720Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37548 (GCVE-0-2023-37548)
Vulnerability from nvd – Published: 2023-08-03 11:02 – Updated: 2024-10-11 18:12
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37548",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:49.760916Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:26.294Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:02:02.224Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37548",
"datePublished": "2023-08-03T11:02:02.224Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:26.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37547 (GCVE-0-2023-37547)
Vulnerability from nvd – Published: 2023-08-03 11:01 – Updated: 2024-10-11 18:12
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.418Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37547",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:39.095120Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:55.550Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:01:10.534Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37547",
"datePublished": "2023-08-03T11:01:10.534Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:55.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37546 (GCVE-0-2023-37546)
Vulnerability from nvd – Published: 2023-08-03 11:00 – Updated: 2024-10-11 18:14
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37546",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:33.810402Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:14:28.818Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:00:33.624Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37546",
"datePublished": "2023-08-03T11:00:33.624Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:14:28.818Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3663 (GCVE-0-2023-3663)
Vulnerability from nvd – Published: 2023-08-03 10:55 – Updated: 2025-02-27 21:11
VLAI?
Title
CODESYS: Missing integrity check in CODESYS Development System
Summary
In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server.
Severity ?
8.8 (High)
CWE
- CWE-940 - Improper Verification of Source of a Communication Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Development System |
Affected:
3.5.11.20 , < 3.5.19.20
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.323Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-022/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3663",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:54:28.867674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T21:11:34.700Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.20",
"status": "affected",
"version": "3.5.11.20",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server."
}
],
"value": "In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-940",
"description": "CWE-940 Improper Verification of Source of a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T05:35:40.245Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-022/"
}
],
"source": {
"advisory": "VDE-2023-022",
"defect": [
"CERT@VDE#64561"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Missing integrity check in CODESYS Development System",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3663",
"datePublished": "2023-08-03T10:55:08.945Z",
"dateReserved": "2023-07-13T13:04:46.976Z",
"dateUpdated": "2025-02-27T21:11:34.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3662 (GCVE-0-2023-3662)
Vulnerability from nvd – Published: 2023-08-03 10:55 – Updated: 2025-02-27 21:11
VLAI?
Title
CODESYS: Vulnerability in CODESYS Development System allows for execution of binaries
Summary
In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context .
Severity ?
7.3 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Development System |
Affected:
3.5.17.0 , < 3.5.19.20
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-021/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3662",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:54:27.291596Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T21:11:28.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.20",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context ."
}
],
"value": "In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context ."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T10:55:43.844Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-021/"
}
],
"source": {
"advisory": "VDE-2023-021",
"defect": [
"CERT@VDE#64560"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Vulnerability in CODESYS Development System allows for execution of binaries",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3662",
"datePublished": "2023-08-03T10:55:43.844Z",
"dateReserved": "2023-07-13T12:54:10.262Z",
"dateUpdated": "2025-02-27T21:11:28.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37545 (GCVE-0-2023-37545)
Vulnerability from nvd – Published: 2023-08-03 10:59 – Updated: 2024-10-11 18:14
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.338Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37545",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:27.383050Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:14:47.934Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T10:59:28.961Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37545",
"datePublished": "2023-08-03T10:59:28.961Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:14:47.934Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3669 (GCVE-0-2023-3669)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:11 – Updated: 2025-02-27 21:11
VLAI?
Title
CODESYS: Missing Brute-Force protection in CODESYS Development System
Summary
A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.
Severity ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Development System |
Affected:
3.0.0.0 , < 3.5.19.20
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-023"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:51:08.351739Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T21:11:19.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog."
}
],
"value": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:11:05.068Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-023"
}
],
"source": {
"advisory": "VDE-2023-023",
"defect": [
"CERT@VDE#64562"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Missing Brute-Force protection in CODESYS Development System",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3669",
"datePublished": "2023-08-03T11:11:05.068Z",
"dateReserved": "2023-07-14T07:42:23.825Z",
"dateUpdated": "2025-02-27T21:11:19.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Heap-based Buffer Overflow in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity ?
6.5 (Medium)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37555 (GCVE-0-2023-37555)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:51.974Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:33.660Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37555",
"datePublished": "2023-08-03T11:05:33.660Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37554 (GCVE-0-2023-37554)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:05 – Updated: 2024-10-11 18:09
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37554",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:34.979Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553, CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:09.750Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37554",
"datePublished": "2023-08-03T11:05:09.750Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:09:34.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37553 (GCVE-0-2023-37553)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.602Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37553",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:16.403Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:39.061Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37553",
"datePublished": "2023-08-03T11:04:39.061Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:16.403Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37552 (GCVE-0-2023-37552)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37552",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:33.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:04.128Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37552",
"datePublished": "2023-08-03T11:04:04.128Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:33.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37551 (GCVE-0-2023-37551)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:10
VLAI?
Title
CODESYS Files or Directories Accessible to External Parties in CmpApp
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Severity ?
6.5 (Medium)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37551",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:51.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:37.457Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Files or Directories Accessible to External Parties in CmpApp",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37551",
"datePublished": "2023-08-03T11:03:37.457Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:51.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37550 (GCVE-0-2023-37550)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:11
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37550",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:11:18.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:09.222Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37550",
"datePublished": "2023-08-03T11:03:09.222Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:11:18.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37549 (GCVE-0-2023-37549)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:02 – Updated: 2024-10-11 18:12
VLAI?
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37549",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:40.613696Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:01.720Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:02:33.725Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37549",
"datePublished": "2023-08-03T11:02:33.725Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:01.720Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}