Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for dcs-5010l by dlink

    VAR-201704-1588

    Vulnerability from variot - Updated: 2025-04-20 22:12

    D-Link DCS cameras have a weak/insecure CrossDomain.XML file that allows sites hosting malicious Flash objects to access and/or change the device's settings via a CSRF attack. This is because of the 'allow-access-from domain' child element set to *, thus accepting requests from any domain. If a victim logged into the camera's web console visits a malicious site hosting a malicious Flash file from another Browser tab, the malicious Flash file then can send requests to the victim's DCS series Camera without knowing the credentials. An attacker can host a malicious Flash file that can retrieve Live Feeds or information from the victim's DCS series Camera, add new admin users, or make other changes to the device. Known affected devices are DCS-933L with firmware before 1.13.05, DCS-5030L, DCS-5020L, DCS-2530L, DCS-2630L, DCS-930L, DCS-932L, and DCS-932LB1. plural D-Link DCS The camera contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. D-LinkDCS-933L is a wireless surveillance camera device from D-Link. There are security holes in several D-LinkDCS cameras. D-Link DCS-933L, etc. The following products are affected: D-Link DCS-5030L; DCS-5020L; DCS-2530L; DCS-2630L;

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201704-1588",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dcs-5009l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.07.05"
          },
          {
            "model": "dcs-7010l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.08.01"
          },
          {
            "model": "dcs-2136l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.04.01"
          },
          {
            "model": "dcs-930l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.13.15"
          },
          {
            "model": "dcs-2330l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.00"
          },
          {
            "model": "dcs-931l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.05"
          },
          {
            "model": "dcs-2310l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.08.01"
          },
          {
            "model": "dcs-5000l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.02.02"
          },
          {
            "model": "dcs-5222l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.12.00"
          },
          {
            "model": "dcs-942l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.11.03"
          },
          {
            "model": "dcs-2132l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.08.01"
          },
          {
            "model": "dcs-932l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.13.15"
          },
          {
            "model": "dcs-2310l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.03.00"
          },
          {
            "model": "dcs-932l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.04"
          },
          {
            "model": "dcs-6212l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.00.12"
          },
          {
            "model": "dcs-2132l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.12.00"
          },
          {
            "model": "dcs-7000l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.04.00"
          },
          {
            "model": "dcs-5025l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.02.10"
          },
          {
            "model": "dcs-5029l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.12.00"
          },
          {
            "model": "dcs-942l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.27"
          },
          {
            "model": "dcs-5010l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.05"
          },
          {
            "model": "dcs-5020l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.05"
          },
          {
            "model": "dcs-930l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.15.04"
          },
          {
            "model": "dcs-934l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.04.15"
          },
          {
            "model": "dcs-2210l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.03.01"
          },
          {
            "model": "dcs-6010l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.15.01"
          },
          {
            "model": "dcs-2530l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.00.21"
          },
          {
            "model": "dcs-2332l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.08.01"
          },
          {
            "model": "dcs-5030l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.01.06"
          },
          {
            "model": "dcs-2230l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.03.01"
          },
          {
            "model": "dcs-933l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.13.05"
          },
          {
            "model": "dcs-2132l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2136l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2210l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2230l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2310l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2330l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2332l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-2530l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5000l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5009l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5010l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5020l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5025l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5029l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5030l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-5222l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-6010l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-6212l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-7000l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-7010l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-930l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-931l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-932l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-933l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-934l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs-942l",
            "scope": null,
            "trust": 0.8,
            "vendor": "d link",
            "version": null
          },
          {
            "model": "dcs",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-933l",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-5030l",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-5020l",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-2530l",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-2630l",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.05"
          },
          {
            "model": "dcs-7000l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.04.00"
          },
          {
            "model": "dcs-2136l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.04.01"
          },
          {
            "model": "dcs-5000l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.02.02"
          },
          {
            "model": "dcs-5029l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.12.00"
          },
          {
            "model": "dcs-2310l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "2.03.00"
          },
          {
            "model": "dcs-2330l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.13.00"
          },
          {
            "model": "dcs-2132l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "2.12.00"
          },
          {
            "model": "dcs-2132l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.08.01"
          },
          {
            "model": "dcs-2210l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.03.01"
          },
          {
            "model": "dcs-5025l",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "d link",
            "version": "1.02.10"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dcs 932l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dcs 942l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dcs 2310l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dcs 2132l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dcs 930l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2230l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 934l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 931l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 933l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5009l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5010l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5020l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5000l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5025l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5030l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2210l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2136l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 7000l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 6212l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5222l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 5029l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2332l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2330l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 6010l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 7010l",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dcs 2530l",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2132l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2136l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2210l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2230l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2310l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2330l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2332l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-2530l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5000l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5009l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5010l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5020l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5025l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5029l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5030l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5222l__firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-6010l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-6212l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-7000l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-7010l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-930l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-931l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-932l_camera_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-933l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-934l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-942l_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          }
        ]
      },
      "cve": "CVE-2017-7852",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2017-7852",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2017-06729",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-116055",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-7852",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-7852",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-7852",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-7852",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-06729",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201704-783",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-116055",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "D-Link DCS cameras have a weak/insecure CrossDomain.XML file that allows sites hosting malicious Flash objects to access and/or change the device\u0027s settings via a CSRF attack. This is because of the \u0027allow-access-from domain\u0027 child element set to *, thus accepting requests from any domain. If a victim logged into the camera\u0027s web console visits a malicious site hosting a malicious Flash file from another Browser tab, the malicious Flash file then can send requests to the victim\u0027s DCS series Camera without knowing the credentials. An attacker can host a malicious Flash file that can retrieve Live Feeds or information from the victim\u0027s DCS series Camera, add new admin users, or make other changes to the device. Known affected devices are DCS-933L with firmware before 1.13.05, DCS-5030L, DCS-5020L, DCS-2530L, DCS-2630L, DCS-930L, DCS-932L, and DCS-932LB1. plural D-Link DCS The camera contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. D-LinkDCS-933L is a wireless surveillance camera device from D-Link. There are security holes in several D-LinkDCS cameras. D-Link DCS-933L, etc. The following products are affected: D-Link DCS-5030L; DCS-5020L; DCS-2530L; DCS-2630L;",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          }
        ],
        "trust": 2.43
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-116055",
            "trust": 0.1,
            "type": "unknown"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-7852",
            "trust": 3.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "76B829DA-D734-4842-BAE5-3DD9FF5F23DC",
            "trust": 0.2
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "EXPLOIT-DB",
            "id": "42074",
            "trust": 0.1
          },
          {
            "db": "PACKETSTORM",
            "id": "142702",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "id": "VAR-201704-1588",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          }
        ],
        "trust": 1.675429490909091
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT",
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          },
          {
            "category": [
              "camera device"
            ],
            "sub_category": "camera",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          }
        ]
      },
      "last_update_date": "2025-04-20T22:12:28.666000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "http://us.dlink.com/"
          },
          {
            "title": "Patch for D-LinkDCS Cross-site Forgery Request Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/93817"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://www.qualys.com/2017/02/22/qsa-2017-02-22/qsa-2017-02-22.pdf"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7852"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7852"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-16T00:00:00",
            "db": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
          },
          {
            "date": "2017-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "date": "2017-04-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "date": "2017-06-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "date": "2017-04-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "date": "2017-04-24T10:59:00.160000",
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06729"
          },
          {
            "date": "2017-05-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116055"
          },
          {
            "date": "2017-06-01T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          },
          {
            "date": "2021-04-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-7852"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  D-Link DCS Cross-site request forgery vulnerability in camera",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-003648"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "cross-site request forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-783"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201905-1066

    Vulnerability from variot - Updated: 2025-01-30 20:44

    The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). plural D-Link DCS series Product Wi-Fi camera Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DCS-5009L and so on are all DCS series IP cameras produced by Taiwan D-Link Company. Alphapd in several D-Link products has a stack-based buffer overflow vulnerability. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc. The following products and versions are affected: D-Link DCS-5009L 1.08.11 and earlier; DCS-5010L 1.14.09 and earlier; DCS-5020L 1.15.12 and earlier; DCS-5025L 1.03.07 and earlier; DCS-5030L 1.04.10 and earlier; DCS-930L 2.16.01 and earlier; DCS-931L 1.14.11 and earlier; DCS-932L 2.17.01 and earlier; DCS-933L 1.14.11 and earlier; DCS-934L 1.05.04 and earlier versions

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201905-1066",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dcs-934l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.05.04"
          },
          {
            "model": "dcs-5030l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.04.10"
          },
          {
            "model": "dcs-5009l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.08.11"
          },
          {
            "model": "dcs-932l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.17.01"
          },
          {
            "model": "dcs-931l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.14.11"
          },
          {
            "model": "dcs-933l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.14.11"
          },
          {
            "model": "dcs-5025l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.03.07"
          },
          {
            "model": "dcs-930l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "2.16.01"
          },
          {
            "model": "dcs-5010l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.14.09"
          },
          {
            "model": "dcs-5020l",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "dlink",
            "version": "1.15.12"
          },
          {
            "model": "dcs-5009l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.08.11"
          },
          {
            "model": "dcs-5010l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.14.09"
          },
          {
            "model": "dcs-5020l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.15.12"
          },
          {
            "model": "dcs-5025l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.03.07"
          },
          {
            "model": "dcs-5030l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.04.10"
          },
          {
            "model": "dcs-930l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "2.16.01"
          },
          {
            "model": "dcs-931l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.14.11"
          },
          {
            "model": "dcs-932l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "2.17.01"
          },
          {
            "model": "dcs-933l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.14.11"
          },
          {
            "model": "dcs-934l",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "d link",
            "version": "1.05.04"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5009l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5010l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5020l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5025l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-5030l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-930l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-931l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-932l_camera_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-933l_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:d-link:dcs-934l_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          }
        ]
      },
      "cve": "CVE-2019-10999",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2019-10999",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "VHN-142601",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2019-10999",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-10999",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-10999",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201905-138",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-142601",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2019-10999",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera\u0027s web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). plural D-Link DCS series Product Wi-Fi camera Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DCS-5009L and so on are all DCS series IP cameras produced by Taiwan D-Link Company. Alphapd in several D-Link products has a stack-based buffer overflow vulnerability. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc. The following products and versions are affected: D-Link DCS-5009L 1.08.11 and earlier; DCS-5010L 1.14.09 and earlier; DCS-5020L 1.15.12 and earlier; DCS-5025L 1.03.07 and earlier; DCS-5030L 1.04.10 and earlier; DCS-930L 2.16.01 and earlier; DCS-931L 1.14.11 and earlier; DCS-932L 2.17.01 and earlier; DCS-933L 1.14.11 and earlier; DCS-934L 1.05.04 and earlier versions",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-10999",
            "trust": 2.7
          },
          {
            "db": "DLINK",
            "id": "SAP10131",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138",
            "trust": 0.7
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "id": "VAR-201905-1066",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          }
        ],
        "trust": 0.824516308
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "camera device"
            ],
            "sub_category": "camera",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-01-30T20:44:51.193000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.dlink.com/en/consumer"
          },
          {
            "title": "CVE-2019-10999",
            "trust": 0.1,
            "url": "https://github.com/qjh2333/CVE-2019-10999 "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/developer3000S/PoC-in-GitHub "
          },
          {
            "title": "",
            "trust": 0.1,
            "url": "https://github.com/khulnasoft-lab/awesome-security "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/hectorgie/PoC-in-GitHub "
          },
          {
            "title": "CVE-POC",
            "trust": 0.1,
            "url": "https://github.com/0xT11/CVE-POC "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/nomi-sec/PoC-in-GitHub "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/fuzzywalls/cve-2019-10999"
          },
          {
            "trust": 1.8,
            "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=sap10131"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10999"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10999"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/787.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/qjh2333/cve-2019-10999"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/nomi-sec/poc-in-github"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-05-06T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "date": "2019-05-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "date": "2019-05-31T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "date": "2019-05-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "date": "2019-05-06T20:29:01.210000",
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142601"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-10999"
          },
          {
            "date": "2019-05-31T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          },
          {
            "date": "2024-11-21T04:20:19.520000",
            "db": "NVD",
            "id": "CVE-2019-10999"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  D-Link DCS series Product  Wi-Fi camera Buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004361"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201905-138"
          }
        ],
        "trust": 0.6
      }
    }