Search
Find a vulnerability
Search criteria
6 vulnerabilities found for controledge_rtu_firmware by honeywell
CVE-2022-30318 (GCVE-0-2022-30318)
Vulnerability from nvd – Published: 2022-08-31 15:39 – Updated: 2024-08-03 06:48
VLAI
Summary
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.forescout.com/blog/ | x_refsource_MISC |
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:48:35.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.forescout.com/blog/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T15:39:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.forescout.com/blog/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-30318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.forescout.com/blog/",
"refsource": "MISC",
"url": "https://www.forescout.com/blog/"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-30318",
"datePublished": "2022-08-31T15:39:14.000Z",
"dateReserved": "2022-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T06:48:35.988Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10628 (GCVE-0-2020-10628)
Vulnerability from nvd – Published: 2020-06-26 16:06 – Updated: 2024-08-04 11:06
VLAI
Summary
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
Severity
No CVSS data available.
CWE
- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-175-02 | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | ControlEdge PLC |
Affected:
R130.2
Affected: R140 Affected: R150 Affected: R151 |
|
| n/a | ControlEdge RTU |
Affected:
R101
Affected: R110 Affected: R140 Affected: R150 Affected: R151 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:06:10.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ControlEdge PLC",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R130.2"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
},
{
"product": "ControlEdge RTU",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R101"
},
{
"status": "affected",
"version": "R110"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-26T16:06:26.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-10628",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ControlEdge PLC",
"version": {
"version_data": [
{
"version_value": "R130.2"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
},
{
"product_name": "ControlEdge RTU",
"version": {
"version_data": [
{
"version_value": "R101"
},
{
"version_value": "R110"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-10628",
"datePublished": "2020-06-26T16:06:26.000Z",
"dateReserved": "2020-03-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:06:10.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10624 (GCVE-0-2020-10624)
Vulnerability from nvd – Published: 2020-06-26 16:22 – Updated: 2024-08-04 11:06
VLAI
Summary
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
Severity
No CVSS data available.
CWE
- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-175-02 | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | ControlEdge PLC |
Affected:
R130.2
Affected: R140 Affected: R150 Affected: R151 |
|
| n/a | ControlEdge RTU |
Affected:
R101
Affected: R110 Affected: R140 Affected: R150 Affected: R151 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:06:10.188Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ControlEdge PLC",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R130.2"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
},
{
"product": "ControlEdge RTU",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R101"
},
{
"status": "affected",
"version": "R110"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-26T16:22:46.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-10624",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ControlEdge PLC",
"version": {
"version_data": [
{
"version_value": "R130.2"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
},
{
"product_name": "ControlEdge RTU",
"version": {
"version_data": [
{
"version_value": "R101"
},
{
"version_value": "R110"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-10624",
"datePublished": "2020-06-26T16:22:46.000Z",
"dateReserved": "2020-03-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:06:10.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30318 (GCVE-0-2022-30318)
Vulnerability from cvelistv5 – Published: 2022-08-31 15:39 – Updated: 2024-08-03 06:48
VLAI
Summary
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.forescout.com/blog/ | x_refsource_MISC |
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:48:35.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.forescout.com/blog/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T15:39:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.forescout.com/blog/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-30318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.forescout.com/blog/",
"refsource": "MISC",
"url": "https://www.forescout.com/blog/"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-30318",
"datePublished": "2022-08-31T15:39:14.000Z",
"dateReserved": "2022-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T06:48:35.988Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10624 (GCVE-0-2020-10624)
Vulnerability from cvelistv5 – Published: 2020-06-26 16:22 – Updated: 2024-08-04 11:06
VLAI
Summary
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
Severity
No CVSS data available.
CWE
- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-175-02 | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | ControlEdge PLC |
Affected:
R130.2
Affected: R140 Affected: R150 Affected: R151 |
|
| n/a | ControlEdge RTU |
Affected:
R101
Affected: R110 Affected: R140 Affected: R150 Affected: R151 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:06:10.188Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ControlEdge PLC",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R130.2"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
},
{
"product": "ControlEdge RTU",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R101"
},
{
"status": "affected",
"version": "R110"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-26T16:22:46.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-10624",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ControlEdge PLC",
"version": {
"version_data": [
{
"version_value": "R130.2"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
},
{
"product_name": "ControlEdge RTU",
"version": {
"version_data": [
{
"version_value": "R101"
},
{
"version_value": "R110"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-10624",
"datePublished": "2020-06-26T16:22:46.000Z",
"dateReserved": "2020-03-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:06:10.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10628 (GCVE-0-2020-10628)
Vulnerability from cvelistv5 – Published: 2020-06-26 16:06 – Updated: 2024-08-04 11:06
VLAI
Summary
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
Severity
No CVSS data available.
CWE
- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-175-02 | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | ControlEdge PLC |
Affected:
R130.2
Affected: R140 Affected: R150 Affected: R151 |
|
| n/a | ControlEdge RTU |
Affected:
R101
Affected: R110 Affected: R140 Affected: R150 Affected: R151 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:06:10.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ControlEdge PLC",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R130.2"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
},
{
"product": "ControlEdge RTU",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "R101"
},
{
"status": "affected",
"version": "R110"
},
{
"status": "affected",
"version": "R140"
},
{
"status": "affected",
"version": "R150"
},
{
"status": "affected",
"version": "R151"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-26T16:06:26.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-10628",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ControlEdge PLC",
"version": {
"version_data": [
{
"version_value": "R130.2"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
},
{
"product_name": "ControlEdge RTU",
"version": {
"version_data": [
{
"version_value": "R101"
},
{
"version_value": "R110"
},
{
"version_value": "R140"
},
{
"version_value": "R150"
},
{
"version_value": "R151"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-175-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-10628",
"datePublished": "2020-06-26T16:06:26.000Z",
"dateReserved": "2020-03-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:06:10.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}