CVE-2023-6357 (GCVE-0-2023-6357)

Vulnerability from nvd – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI?
Title
OS Command Injection in multiple CODESYS products
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Credits
Chuya Hayakawa of 00One, Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.783Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux ARM SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Runtime Toolkit for Linux or QNX",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.19.50",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chuya Hayakawa of 00One, Inc."
        }
      ],
      "datePublic": "2023-12-05T14:25:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
            }
          ],
          "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-05T14:29:25.649Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
        }
      ],
      "source": {
        "advisory": "VDE-2023-066",
        "defect": [
          "CERT@VDE#64623"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "OS Command Injection in multiple CODESYS products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-6357",
    "datePublished": "2023-12-05T14:29:25.649Z",
    "dateReserved": "2023-11-28T07:20:59.774Z",
    "dateUpdated": "2024-08-02T08:28:21.783Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-29242 (GCVE-0-2021-29242)

Vulnerability from nvd – Published: 2021-05-03 13:56 – Updated: 2024-08-03 22:02
VLAI?
Summary
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.582Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.codesys.com/security/security-reports.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-03T13:56:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.codesys.com/security/security-reports.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-29242",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php"
            },
            {
              "name": "https://www.codesys.com/security/security-reports.html",
              "refsource": "MISC",
              "url": "https://www.codesys.com/security/security-reports.html"
            },
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-29242",
    "datePublished": "2021-05-03T13:56:06",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.582Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6357 (GCVE-0-2023-6357)

Vulnerability from cvelistv5 – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI?
Title
OS Command Injection in multiple CODESYS products
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Credits
Chuya Hayakawa of 00One, Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.783Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux ARM SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.11.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Runtime Toolkit for Linux or QNX",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.19.50",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chuya Hayakawa of 00One, Inc."
        }
      ],
      "datePublic": "2023-12-05T14:25:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
            }
          ],
          "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-05T14:29:25.649Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
        }
      ],
      "source": {
        "advisory": "VDE-2023-066",
        "defect": [
          "CERT@VDE#64623"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "OS Command Injection in multiple CODESYS products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-6357",
    "datePublished": "2023-12-05T14:29:25.649Z",
    "dateReserved": "2023-11-28T07:20:59.774Z",
    "dateUpdated": "2024-08-02T08:28:21.783Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-29242 (GCVE-0-2021-29242)

Vulnerability from cvelistv5 – Published: 2021-05-03 13:56 – Updated: 2024-08-03 22:02
VLAI?
Summary
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.582Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.codesys.com/security/security-reports.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-03T13:56:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.codesys.com/security/security-reports.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-29242",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php"
            },
            {
              "name": "https://www.codesys.com/security/security-reports.html",
              "refsource": "MISC",
              "url": "https://www.codesys.com/security/security-reports.html"
            },
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-29242",
    "datePublished": "2021-05-03T13:56:06",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.582Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}