Search criteria
8 vulnerabilities found for connected_grid_network_management_system by cisco
CVE-2017-6780 (GCVE-0-2017-6780)
Vulnerability from nvd – Published: 2017-09-07 21:00 – Updated: 2024-08-05 15:41
VLAI?
Summary
A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Cisco IoT Field Network Director |
Affected:
Cisco IoT Field Network Director
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:41:17.290Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100641"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Cisco IoT Field Network Director",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco IoT Field Network Director"
}
]
}
],
"datePublic": "2017-09-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-399",
"description": "CWE-399",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-08T09:57:01",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100641"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2017-6780",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IoT Field Network Director",
"version": {
"version_data": [
{
"version_value": "Cisco IoT Field Network Director"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-399"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100641"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2017-6780",
"datePublished": "2017-09-07T21:00:00",
"dateReserved": "2017-03-09T00:00:00",
"dateUpdated": "2024-08-05T15:41:17.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-6362 (GCVE-0-2015-6362)
Vulnerability from nvd – Published: 2015-11-10 02:00 – Updated: 2024-08-06 07:22
VLAI?
Summary
The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:22:20.935Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1034106"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-11-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-05T22:57:01",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1034106"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2015-6362",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1034106"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2015-6362",
"datePublished": "2015-11-10T02:00:00",
"dateReserved": "2015-08-17T00:00:00",
"dateUpdated": "2024-08-06T07:22:20.935Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-1171 (GCVE-0-2013-1171)
Vulnerability from nvd – Published: 2013-04-01 19:00 – Updated: 2024-09-16 17:17
VLAI?
Summary
Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:49:20.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-01T19:00:00Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2013-1171",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2013-1171",
"datePublished": "2013-04-01T19:00:00Z",
"dateReserved": "2013-01-11T00:00:00Z",
"dateUpdated": "2024-09-16T17:17:40.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-1163 (GCVE-0-2013-1163)
Vulnerability from nvd – Published: 2013-04-01 19:00 – Updated: 2024-09-16 22:56
VLAI?
Summary
Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:49:20.689Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-01T19:00:00Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2013-1163",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2013-1163",
"datePublished": "2013-04-01T19:00:00Z",
"dateReserved": "2013-01-11T00:00:00Z",
"dateUpdated": "2024-09-16T22:56:12.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6780 (GCVE-0-2017-6780)
Vulnerability from cvelistv5 – Published: 2017-09-07 21:00 – Updated: 2024-08-05 15:41
VLAI?
Summary
A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Cisco IoT Field Network Director |
Affected:
Cisco IoT Field Network Director
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:41:17.290Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100641"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Cisco IoT Field Network Director",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco IoT Field Network Director"
}
]
}
],
"datePublic": "2017-09-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-399",
"description": "CWE-399",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-08T09:57:01",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100641"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2017-6780",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IoT Field Network Director",
"version": {
"version_data": [
{
"version_value": "Cisco IoT Field Network Director"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-399"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd"
},
{
"name": "100641",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100641"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2017-6780",
"datePublished": "2017-09-07T21:00:00",
"dateReserved": "2017-03-09T00:00:00",
"dateUpdated": "2024-08-05T15:41:17.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-6362 (GCVE-0-2015-6362)
Vulnerability from cvelistv5 – Published: 2015-11-10 02:00 – Updated: 2024-08-06 07:22
VLAI?
Summary
The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:22:20.935Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1034106"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-11-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-05T22:57:01",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1034106"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2015-6362",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web GUI in Cisco Connected Grid Network Management System (CG-NMS) 3.0(0.35) and 3.0(0.54) allows remote authenticated users to bypass intended access restrictions and modify the configuration by leveraging the Monitor-Only role, aka Bug ID CSCuw42640."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20151109 Cisco Connected Grid Network Management System Privilege Escalation Vulnerability",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20151109-cg-nms"
},
{
"name": "1034106",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1034106"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2015-6362",
"datePublished": "2015-11-10T02:00:00",
"dateReserved": "2015-08-17T00:00:00",
"dateUpdated": "2024-08-06T07:22:20.935Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-1171 (GCVE-0-2013-1171)
Vulnerability from cvelistv5 – Published: 2013-04-01 19:00 – Updated: 2024-09-16 17:17
VLAI?
Summary
Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:49:20.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-01T19:00:00Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2013-1171",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple cross-site scripting (XSS) vulnerabilities in the element-list implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors, aka Bug IDs CSCue14517, CSCue38914, CSCue38884, CSCue38882, CSCue38881, CSCue38872, CSCue38868, CSCue38866, CSCue38853, and CSCue14540."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130401 Cisco Connected Grid Network Management System Cross-Site Scripting Vulnerabilities",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1171"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2013-1171",
"datePublished": "2013-04-01T19:00:00Z",
"dateReserved": "2013-01-11T00:00:00Z",
"dateUpdated": "2024-09-16T17:17:40.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-1163 (GCVE-0-2013-1163)
Vulnerability from cvelistv5 – Published: 2013-04-01 19:00 – Updated: 2024-09-16 22:56
VLAI?
Summary
Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:49:20.689Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-01T19:00:00Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2013-1163",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple SQL injection vulnerabilities in the device-management implementation in Cisco Connected Grid Network Management System (CG-NMS) allow remote attackers to execute arbitrary SQL commands via unspecified vectors, aka Bug IDs CSCue14553 and CSCue38746."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20130401 Cisco Connected Grid Network Management System SQL Injection Vulnerabilities",
"refsource": "CISCO",
"url": "http://tools.cisco.com/security/center/content/CiscoSecurityNotice/CVE-2013-1163"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2013-1163",
"datePublished": "2013-04-01T19:00:00Z",
"dateReserved": "2013-01-11T00:00:00Z",
"dateUpdated": "2024-09-16T22:56:12.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}