    FKIE_CVE-2022-0778

    Vulnerability from fkie_nvd - Published: 2022-03-15 17:15 - Updated: 2026-10-14 13:17
    Summary
    The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
    References
    openssl-security@openssl.orghttp://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.htmlThird Party Advisory, VDB Entry
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/33Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/35Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/38Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdfThird Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2022/03/msg00023.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2022/03/msg00024.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002Third Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202210-02Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20220321-0002/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20220429-0005/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213255Third Party Advisory
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213256Third Party Advisory
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213257Third Party Advisory
    openssl-security@openssl.orghttps://www.debian.org/security/2022/dsa-5103Third Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20220315.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-06Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-07Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-08Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.htmlThird Party Advisory, VDB Entry
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/33Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/35Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/38Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2022/03/msg00023.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2022/03/msg00024.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202210-02Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20220321-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20220429-0005/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213255Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213256Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213257Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2022/dsa-5103Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20220315.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-06Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-07Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-08Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-09Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-019200.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-028723.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-108696.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-398330.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-712929.html

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "BFCClient",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.17",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge - OPC UA Connector",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.7.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge - SIMATIC S7 Connector App",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.7.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V8.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V9.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V9.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM RM1224 LTE(4G) EU",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX MX5000",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX MX5000RE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1400",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1500",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1501",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1510",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1511",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1524",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1536",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX5000",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9403",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 HF0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M804PB",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M812-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M812-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M816-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M816-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M826-2 SHDSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M874-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M874-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-3 (ROK)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4 (NAM)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM853-1 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM856-1 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM856-1 (RoW)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE S615 EEC LAN-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE S615 LAN-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC622-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC632-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC636-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC642-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC646-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (JP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (ROW)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2 EEC M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2IA M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 (US)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 EEC (US)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM766-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM766-1 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X200-4P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X201-3P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X201-3P IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2P IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2FM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2LD TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X206-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X206-1LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X208PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X212-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X212-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X224",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X304-2FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X306-1LD FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2 RD (inkl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X320-1 FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X320-1-2LD FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X408-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3LD (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3LD (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB208 (E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB208 (PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (ST, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3LD (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3LD (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB216 (E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB216 (PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2 (SC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2 (ST/BFOC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G (EIP def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-3G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-3G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G (EIP Def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G (EIP Def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF201-3P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204 DNA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA DNA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF206-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-4C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-8C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-8C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM416-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM416-4C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208 (Ethernet/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208PoE EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216 (Ethernet/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216POE EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M TS (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M TS (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR326-2C PoE WG",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR326-2C PoE WG (without UL)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 1x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 24V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 24V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 2x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 1x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 24V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 24V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 2x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Security Configuration Tool (SCT)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Cloud Connect 7 CC712",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.9.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Cloud Connect 7 CC716",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.9.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1242-7 V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-7 LTE EU",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-7 LTE US",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-8 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1542SP-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1543-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.37",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1543SP-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1545-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.1.80",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1626",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1628",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 343-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 443-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 443-1 OPC UA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Drive Controller CPU 1504D TF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Drive Controller CPU 1507D TF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V21.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC HMI Unified Comfort Panels family",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18.0 Update 0 SR0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Logon V1.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.6 Upd6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V16 Update 6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 TeleControl",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V8.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V9.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V9.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.1 SP2 UC04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo (Administration Console)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PDM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.2 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Process Historian OPC UA Server",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2020 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF166C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF185C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF186C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF186CI",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF188C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF188CI",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF360R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF610R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF615R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF650R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF680R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF685R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 Software Controller V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V21.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-PLCSIM Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.7 HF4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.4 SP1 Update 22",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.5 SP2 Update 16",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.1",
                  "status": "affected",
                  "version": "V5.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION SCOUT TIA V5.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION SCOUT TIA V5.4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCC V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCC V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAUT Software ST7sc",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAUT ST7CC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC INS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0 SP3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Server",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 1242-7 V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 1543-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.37",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 343-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 443-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE X202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC206-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC206-2SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC216-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CP 1243-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS TIM 1531 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.4.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Safety ES V17 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V15.1 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V16 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TeleControl Server Basic V3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Portal Cloud V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Portal Cloud V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIM 1531 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.4.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3BC593C-D7BB-42A8-9488-BE910A8C3B68",
                  "versionEndExcluding": "1.0.2zd",
                  "versionStartIncluding": "1.0.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "16D7B14C-9D04-40AC-9FCE-73D3DF468DB2",
                  "versionEndExcluding": "1.1.1n",
                  "versionStartIncluding": "1.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7225F27-E0BC-4716-AF68-8D68EE90F7CE",
                  "versionEndExcluding": "3.0.2",
                  "versionStartIncluding": "3.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FA6FEEC2-9F11-4643-8827-749718254FED",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:clustered_data_ontap:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1FE996B1-6951-4F85-AA58-B99A379D2163",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:clustered_data_ontap_antivirus_connector:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "62347994-1353-497C-9C4A-D5D8D95F67E8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:a250_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1236B66D-EB11-4324-929F-E2B86683C3C7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:a250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "281DFC67-46BB-4FC2-BE03-3C65C9311F65",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:500f_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ECF32BB1-9A58-4821-AE49-5D5C8200631F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:500f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F21DE67F-CDFD-4D36-9967-633CD0240C6F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:36:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C675112-476C-4D7C-BCB9-A2FB2D0BC9FD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1188273E-D496-41A9-AE16-75C0EB70EFB2",
                  "versionEndExcluding": "8.15.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "644DD241-261E-41A3-86B5-C0834502EA81",
                  "versionEndExcluding": "10.1.2",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49CFE4A3-DDFC-4801-8C68-510EB5CFBC36",
                  "versionEndExcluding": "10.2.42",
                  "versionStartIncluding": "10.2.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F8EB13E9-AFD7-4E82-A471-61201460CAC4",
                  "versionEndExcluding": "10.3.33",
                  "versionStartIncluding": "10.3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3EFE42EF-DB07-4DD4-A40C-6DD6A7D1E6DC",
                  "versionEndExcluding": "10.4.23",
                  "versionStartIncluding": "10.4.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E3C63CE6-6B86-4C48-8D30-DC74CA83C5EC",
                  "versionEndExcluding": "10.5.14",
                  "versionStartIncluding": "10.5.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09ADA35C-125F-4970-ACB7-36A9CC3516BF",
                  "versionEndExcluding": "10.6.6",
                  "versionStartIncluding": "10.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E0435104-B0F9-4997-A769-36821689DF45",
                  "versionEndExcluding": "10.7.2",
                  "versionStartIncluding": "10.7.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
                  "versionEndIncluding": "12.12.0",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "274A9803-2997-4E65-BDB0-8B5C23120CD1",
                  "versionEndExcluding": "12.22.11",
                  "versionStartIncluding": "12.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "05678B4E-5F27-4096-8E9B-38B84A7E7793",
                  "versionEndIncluding": "14.14.0",
                  "versionStartExcluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "CECEE1EE-B2A2-476B-82AE-48DFF6F1729A",
                  "versionEndExcluding": "14.19.1",
                  "versionStartIncluding": "14.15.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "DC9C8402-7102-4BCF-8A49-CFDF1C59B92F",
                  "versionEndIncluding": "16.12.0",
                  "versionStartExcluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "3DF34038-6987-4196-B5E7-FF5656D1EE5A",
                  "versionEndExcluding": "16.14.2",
                  "versionStartIncluding": "16.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "0AD8D8BB-702C-4FDF-A0A2-872744B8BF68",
                  "versionEndExcluding": "17.7.2",
                  "versionStartExcluding": "17.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)."
        },
        {
          "lang": "es",
          "value": "La funci\u00f3n BN_mod_sqrt(), que calcula una ra\u00edz cuadrada modular, contiene un error que puede causar un bucle eterno para m\u00f3dulos no primos. Internamente, esta funci\u00f3n es usado cuando son analizados certificados que contienen claves p\u00fablicas de curva el\u00edptica en forma comprimida o par\u00e1metros de curva el\u00edptica expl\u00edcitos con un punto base codificado en forma comprimida. Es posible desencadenar el bucle infinito si es dise\u00f1ado un certificado con par\u00e1metros de curva expl\u00edcitos no v\u00e1lidos. Dado que el an\u00e1lisis del certificado es realizado antes de la verificaci\u00f3n de la firma del certificado, cualquier proceso que analice un certificado suministrado externamente puede ser objeto de un ataque de denegaci\u00f3n de servicio. El bucle infinito tambi\u00e9n puede alcanzarse cuando son analizadas claves privadas dise\u00f1adas, ya que pueden contener par\u00e1metros expl\u00edcitos de la curva el\u00edptica. Por lo tanto, las situaciones vulnerables incluyen: - Clientes TLS que consumen certificados de servidor - Servidores TLS que consumen certificados de cliente - Proveedores de hosting que toman certificados o claves privadas de clientes - Autoridades de certificaci\u00f3n que analizan peticiones de certificaci\u00f3n de suscriptores - Cualquier otra cosa que analice par\u00e1metros de curva el\u00edptica ASN.1 Tambi\u00e9n cualquier otra aplicaci\u00f3n que utilice BN_mod_sqrt() donde el atacante pueda controlar los valores de los par\u00e1metros es vulnerable a este problema de DoS. En OpenSSL versi\u00f3n 1.0.2, la clave p\u00fablica no es analizada durante el an\u00e1lisis inicial del certificado, lo que dificulta ligeramente la activaci\u00f3n del bucle infinito. Sin embargo, cualquier operaci\u00f3n que requiera la clave p\u00fablica del certificado desencadenar\u00e1 el bucle infinito. En particular, el atacante puede usar un certificado autofirmado para desencadenar el bucle durante la verificaci\u00f3n de la firma del certificado. Este problema afecta a OpenSSL versiones 1.0.2, 1.1.1 y 3.0. Fue abordado en las versiones 1.1.1n y 3.0.2 del 15 de marzo de 2022. Corregido en OpenSSL versi\u00f3n 3.0.2 (Afectado 3.0.0,3.0.1). Corregido en OpenSSL versi\u00f3n 1.1.1n (Afectado 1.1.1-1.1.1m). Corregido en OpenSSL versi\u00f3n 1.0.2zd (Afectado 1.0.2-1.0.2zc)"
        }
      ],
      "id": "CVE-2022-0778",
      "lastModified": "2026-10-14T13:17:14.377",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-0778",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-05-22T13:27:14.476267Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-03-15T17:15:08.513",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/33"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/35"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/38"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202210-02"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213255"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213256"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213257"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5103"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20220315.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-06"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-07"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-08"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/33"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/35"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/38"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202210-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213255"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213256"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213257"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5103"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20220315.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-06"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-07"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-08"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-09"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-028723.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-108696.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2019-20907

    Vulnerability from fkie_nvd - Published: 2020-07-13 13:15 - Updated: 2026-10-14 08:17
    Summary
    In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation.
    References
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.htmlMailing List, Third Party Advisory
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.htmlMailing List, Third Party Advisory
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.htmlMailing List, Third Party Advisory
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://bugs.python.org/issue39017Issue Tracking, Vendor Advisory
    cve@mitre.orghttps://github.com/python/cpython/pull/21454Patch, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/08/msg00034.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/11/msg00032.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2023/05/msg00024.html
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/
    cve@mitre.orghttps://security.gentoo.org/glsa/202008-01Third Party Advisory
    cve@mitre.orghttps://security.netapp.com/advisory/ntap-20200731-0002/Third Party Advisory
    cve@mitre.orghttps://usn.ubuntu.com/4428-1/Third Party Advisory
    cve@mitre.orghttps://www.oracle.com/security-alerts/cpujan2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://bugs.python.org/issue39017Issue Tracking, Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/python/cpython/pull/21454Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/08/msg00034.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/11/msg00032.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202008-01Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20200731-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://usn.ubuntu.com/4428-1/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujan2021.htmlPatch, Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-398330.html

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:python:python:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "190C1D3B-648D-46B5-AB7E-8575DB03585B",
                  "versionEndExcluding": "3.5.10",
                  "versionStartIncluding": "3.5.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:python:python:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7EB6A6FC-6C82-4543-8DAA-96FF2BACDB5C",
                  "versionEndExcluding": "3.6.12",
                  "versionStartIncluding": "3.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:python:python:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "045171F0-A76D-4385-B2AE-51479B425C45",
                  "versionEndExcluding": "3.7.9",
                  "versionStartIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:python:python:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9065C407-4FE5-4895-84FC-21B706581C0F",
                  "versionEndExcluding": "3.8.5",
                  "versionStartIncluding": "3.8.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:opensuse:leap:15.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B620311B-34A3-48A6-82DF-6F078D7A4493",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:opensuse:leap:15.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B009C22E-30A4-4288-BCF6-C3E81DEAF45A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:31:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80F0FA5D-8D3B-4C0E-81E2-87998286AF33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:32:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36D96259-24BD-44E2-96D9-78CE1D41F956",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:12.04:*:*:*:esm:*:*:*",
                  "matchCriteriaId": "8D305F7A-D159-4716-AB26-5E38BB5CD991",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm:*:*:*",
                  "matchCriteriaId": "815D70A8-47D3-459C-A32C-9FEACA0659D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "902B8056-9E37-443B-8905-8AA93E2447FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:*:*:*:*:*:vsphere:*:*",
                  "matchCriteriaId": "B64FC591-5854-4480-A6E2-5E953C2415B3",
                  "versionStartIncluding": "9.5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation."
        },
        {
          "lang": "es",
          "value": "En la biblioteca Lib/tarfile.py en Python versiones hasta 3.8.3, un atacante puede dise\u00f1ar un archivo TAR conllevando a un bucle infinito cuando se abri\u00f3 mediante tarfile.open, porque la funci\u00f3n _proc_pax carece de comprobaci\u00f3n  de encabezado"
        }
      ],
      "id": "CVE-2019-20907",
      "lastModified": "2026-10-14T08:17:01.633",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2019-20907",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-07T17:58:36.334729Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2020-07-13T13:15:10.763",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugs.python.org/issue39017"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/python/cpython/pull/21454"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202008-01"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4428-1/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugs.python.org/issue39017"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/python/cpython/pull/21454"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202008-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4428-1/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-3449

    Vulnerability from fkie_nvd - Published: 2021-03-25 15:15 - Updated: 2026-10-08 22:17
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    References
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
    openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    openssl-security@openssl.orghttps://www.debian.org/security/2021/dsa-4875Third Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-06Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-10Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2021/dsa-4875Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-06Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-10Third Party Advisory
    Impacted products
    Vendor Product Version
    openssl openssl *
    debian debian_linux 9.0
    debian debian_linux 10.0
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    netapp active_iq_unified_manager -
    netapp cloud_volumes_ontap_mediator -
    netapp e-series_performance_analyzer -
    netapp oncommand_insight -
    netapp oncommand_workflow_automation -
    netapp ontap_select_deploy_administration_utility -
    netapp santricity_smi-s_provider -
    netapp snapcenter -
    netapp storagegrid -
    tenable log_correlation_engine *
    tenable nessus *
    tenable nessus_network_monitor 5.11.0
    tenable nessus_network_monitor 5.11.1
    tenable nessus_network_monitor 5.12.0
    tenable nessus_network_monitor 5.12.1
    tenable nessus_network_monitor 5.13.0
    tenable tenable.sc *
    fedoraproject fedora 34
    mcafee web_gateway 8.2.19
    mcafee web_gateway 9.2.10
    mcafee web_gateway 10.1.1
    mcafee web_gateway_cloud_service 8.2.19
    mcafee web_gateway_cloud_service 9.2.10
    mcafee web_gateway_cloud_service 10.1.1
    checkpoint quantum_security_management_firmware r80.40
    checkpoint quantum_security_management_firmware r81
    checkpoint quantum_security_management -
    checkpoint multi-domain_management_firmware r80.40
    checkpoint multi-domain_management_firmware r81
    checkpoint multi-domain_management -
    checkpoint quantum_security_gateway_firmware r80.40
    checkpoint quantum_security_gateway_firmware r81
    checkpoint quantum_security_gateway -
    oracle communications_communications_policy_management 12.6.0.0.0
    oracle enterprise_manager_for_storage_management 13.4.0.0
    oracle essbase 21.2
    oracle graalvm 19.3.5
    oracle graalvm 20.3.1.2
    oracle graalvm 21.0.0.2
    oracle jd_edwards_enterpriseone_tools *
    oracle jd_edwards_world_security a9.4
    oracle mysql_connectors *
    oracle mysql_server *
    oracle mysql_server *
    oracle mysql_workbench *
    oracle peoplesoft_enterprise_peopletools 8.57
    oracle peoplesoft_enterprise_peopletools 8.58
    oracle peoplesoft_enterprise_peopletools 8.59
    oracle primavera_unifier *
    oracle primavera_unifier 19.12
    oracle primavera_unifier 20.12
    oracle primavera_unifier 21.12
    oracle secure_backup *
    oracle secure_global_desktop 5.6
    oracle zfs_storage_appliance_kit 8.8
    sonicwall sma100_firmware *
    sonicwall sma100 -
    sonicwall capture_client 3.5
    sonicwall sonicos 7.0.1.0
    siemens ruggedcom_rcm1224_firmware *
    siemens ruggedcom_rcm1224 -
    siemens scalance_lpe9403_firmware *
    siemens scalance_lpe9403 -
    siemens scalance_m-800_firmware *
    siemens scalance_m-800 -
    siemens scalance_s602_firmware *
    siemens scalance_s602 -
    siemens scalance_s612_firmware *
    siemens scalance_s612 -
    siemens scalance_s615_firmware *
    siemens scalance_s615 -
    siemens scalance_s623_firmware *
    siemens scalance_s623 -
    siemens scalance_s627-2m_firmware *
    siemens scalance_s627-2m -
    siemens scalance_sc-600_firmware *
    siemens scalance_sc-600 -
    siemens scalance_w700_firmware *
    siemens scalance_w700 -
    siemens scalance_w1700_firmware *
    siemens scalance_w1700 -
    siemens scalance_xb-200_firmware *
    siemens scalance_xb-200 -
    siemens scalance_xc-200_firmware *
    siemens scalance_xc-200 -
    siemens scalance_xf-200ba_firmware *
    siemens scalance_xf-200ba -
    siemens scalance_xm-400_firmware *
    siemens scalance_xm-400 -
    siemens scalance_xp-200_firmware *
    siemens scalance_xp-200 -
    siemens scalance_xr-300wg_firmware *
    siemens scalance_xr-300wg -
    siemens scalance_xr524-8c_firmware *
    siemens scalance_xr524-8c -
    siemens scalance_xr526-8c_firmware *
    siemens scalance_xr526-8c -
    siemens scalance_xr528-6m_firmware *
    siemens scalance_xr528-6m -
    siemens scalance_xr552-12_firmware *
    siemens scalance_xr552-12 -
    siemens simatic_cloud_connect_7_firmware *
    siemens simatic_cloud_connect_7_firmware -
    siemens simatic_cloud_connect_7 -
    siemens simatic_cp_1242-7_gprs_v2_firmware *
    siemens simatic_cp_1242-7_gprs_v2_firmware -
    siemens simatic_cp_1242-7_gprs_v2 -
    siemens simatic_hmi_basic_panels_2nd_generation_firmware *
    siemens simatic_hmi_basic_panels_2nd_generation -
    siemens simatic_hmi_comfort_outdoor_panels_firmware *
    siemens simatic_hmi_comfort_outdoor_panels -
    siemens simatic_hmi_ktp_mobile_panels_firmware *
    siemens simatic_hmi_ktp_mobile_panels -
    siemens simatic_mv500_firmware *
    siemens simatic_mv500 -
    siemens simatic_net_cp_1243-1_firmware *
    siemens simatic_net_cp_1243-1 -
    siemens simatic_net_cp1243-7_lte_eu_firmware *
    siemens simatic_net_cp1243-7_lte_eu -
    siemens simatic_net_cp1243-7_lte_us_firmware *
    siemens simatic_net_cp1243-7_lte_us -
    siemens simatic_net_cp_1243-8_irc_firmware *
    siemens simatic_net_cp_1243-8_irc -
    siemens simatic_net_cp_1542sp-1_irc_firmware *
    siemens simatic_net_cp_1542sp-1_irc -
    siemens simatic_net_cp_1543-1_firmware *
    siemens simatic_net_cp_1543-1 -
    siemens simatic_net_cp_1543sp-1_firmware *
    siemens simatic_net_cp_1543sp-1 -
    siemens simatic_net_cp_1545-1_firmware *
    siemens simatic_net_cp_1545-1 -
    siemens simatic_pcs_7_telecontrol_firmware *
    siemens simatic_pcs_7_telecontrol -
    siemens simatic_pcs_neo_firmware *
    siemens simatic_pcs_neo -
    siemens simatic_pdm_firmware *
    siemens simatic_pdm -
    siemens simatic_process_historian_opc_ua_server_firmware *
    siemens simatic_process_historian_opc_ua_server -
    siemens simatic_rf166c_firmware *
    siemens simatic_rf166c -
    siemens simatic_rf185c_firmware *
    siemens simatic_rf185c -
    siemens simatic_rf186c_firmware *
    siemens simatic_rf186c -
    siemens simatic_rf186ci_firmware *
    siemens simatic_rf186ci -
    siemens simatic_rf188c_firmware *
    siemens simatic_rf188c -
    siemens simatic_rf188ci_firmware *
    siemens simatic_rf188ci -
    siemens simatic_rf360r_firmware *
    siemens simatic_rf360r -
    siemens simatic_s7-1200_cpu_1211c_firmware *
    siemens simatic_s7-1200_cpu_1211c -
    siemens simatic_s7-1200_cpu_1212c_firmware *
    siemens simatic_s7-1200_cpu_1212c -
    siemens simatic_s7-1200_cpu_1212fc_firmware *
    siemens simatic_s7-1200_cpu_1212fc -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1214c_firmware *
    siemens simatic_s7-1200_cpu_1214c -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1215_fc_firmware *
    siemens simatic_s7-1200_cpu_1215_fc -
    siemens simatic_s7-1200_cpu_1215c_firmware *
    siemens simatic_s7-1200_cpu_1215c -
    siemens simatic_s7-1200_cpu_1217c_firmware *
    siemens simatic_s7-1200_cpu_1217c -
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
    siemens sinamics_connect_300_firmware *
    siemens sinamics_connect_300 -
    siemens tim_1531_irc_firmware *
    siemens tim_1531_irc -
    siemens simatic_logon *
    siemens simatic_logon 1.5
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_telecontrol -
    siemens sinec_nms 1.0
    siemens sinec_nms 1.0
    siemens sinec_pni -
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinumerik_opc_ua_server *
    siemens tia_administrator *
    siemens sinec_infrastructure_network_services *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8",
                  "versionEndExcluding": "1.1.1k",
                  "versionStartIncluding": "1.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
                  "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
                  "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014",
                  "versionEndExcluding": "6.0.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
                  "versionEndIncluding": "8.13.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05",
                  "versionEndIncluding": "5.17.0",
                  "versionStartIncluding": "5.13.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
                  "versionEndExcluding": "9.2.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
                  "versionEndIncluding": "5.7.33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
                  "versionEndIncluding": "8.0.23",
                  "versionStartIncluding": "8.0.15",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9",
                  "versionEndIncluding": "17.12",
                  "versionStartIncluding": "17.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
                  "versionEndExcluding": "18.1.0.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D",
                  "versionEndExcluding": "10.2.1.0-17sv",
                  "versionStartIncluding": "10.2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C",
                  "versionStartIncluding": "6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80",
                  "versionStartIncluding": "1.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB",
                  "versionEndExcluding": "3.0",
                  "versionStartIncluding": "2.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF",
                  "versionStartIncluding": "1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8",
                  "versionStartIncluding": "9.1.0.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D",
                  "versionStartIncluding": "2019",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059",
                  "versionEndExcluding": "2.2",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A",
                  "versionStartIncluding": "1.6.0.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*",
                  "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*",
                  "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*",
                  "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
                  "versionEndExcluding": "1.0.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
                  "versionEndIncluding": "10.12.0",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C",
                  "versionEndIncluding": "10.24.0",
                  "versionStartIncluding": "10.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
                  "versionEndIncluding": "12.12.0",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3",
                  "versionEndExcluding": "12.22.1",
                  "versionStartIncluding": "12.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
                  "versionEndIncluding": "14.14.0",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58",
                  "versionEndExcluding": "14.16.1",
                  "versionStartIncluding": "14.15.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
                  "versionEndExcluding": "15.14.0",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
        },
        {
          "lang": "es",
          "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)"
        }
      ],
      "id": "CVE-2021-3449",
      "lastModified": "2026-10-08T22:17:11.243",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-3449",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:05:43.522199Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-03-25T15:15:13.450",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-3450

    Vulnerability from fkie_nvd - Published: 2021-03-25 15:15 - Updated: 2026-10-08 21:17
    Summary
    The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a "purpose" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named "purpose" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j).
    References
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b
    openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    openssl-security@openssl.orghttps://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.htmlMailing List, Vendor Advisory
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-08Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b
    af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    af854a3a-2127-422b-91ae-364da2661108https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.htmlMailing List, Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-08Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
    Impacted products
    Vendor Product Version
    openssl openssl *
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    netapp santricity_smi-s_provider_firmware -
    netapp santricity_smi-s_provider -
    netapp storagegrid_firmware -
    netapp storagegrid -
    windriver linux -
    windriver linux 17.0
    windriver linux 18.0
    windriver linux 19.0
    netapp cloud_volumes_ontap_mediator -
    netapp oncommand_workflow_automation -
    netapp ontap_select_deploy_administration_utility -
    netapp storagegrid -
    fedoraproject fedora 34
    tenable nessus *
    tenable nessus_agent *
    tenable nessus_network_monitor 5.11.0
    tenable nessus_network_monitor 5.11.1
    tenable nessus_network_monitor 5.12.0
    tenable nessus_network_monitor 5.12.1
    tenable nessus_network_monitor 5.13.0
    oracle commerce_guided_search 11.3.2
    oracle enterprise_manager_for_storage_management 13.4.0.0
    oracle graalvm 19.3.5
    oracle graalvm 20.3.1.2
    oracle graalvm 21.0.0.2
    oracle jd_edwards_enterpriseone_tools *
    oracle jd_edwards_world_security a9.4
    oracle mysql_connectors *
    oracle mysql_enterprise_monitor *
    oracle mysql_server *
    oracle mysql_server *
    oracle mysql_workbench *
    oracle peoplesoft_enterprise_peopletools *
    oracle secure_backup *
    oracle secure_global_desktop 5.6
    oracle weblogic_server 12.2.1.4.0
    oracle weblogic_server 14.1.1.0.0
    mcafee web_gateway 8.2.19
    mcafee web_gateway 9.2.10
    mcafee web_gateway 10.1.1
    mcafee web_gateway_cloud_service 8.2.19
    mcafee web_gateway_cloud_service 9.2.10
    mcafee web_gateway_cloud_service 10.1.1
    sonicwall sma100_firmware *
    sonicwall sma100 -
    sonicwall capture_client *
    sonicwall email_security *
    sonicwall sonicos *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "34F17CB9-A706-45F7-ADCB-F095B0581798",
                  "versionEndExcluding": "1.1.1k",
                  "versionStartIncluding": "1.1.1h",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
                  "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
                  "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:santricity_smi-s_provider_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "255C64D2-51AF-425B-8A01-91DB4D126812",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC1E143B-C678-4F62-B51C-CF2A22E11B12",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:storagegrid_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AA225A10-CED4-484F-ADDB-932FAAECAF5D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "151055B2-9F63-420B-97F4-A434BFBC9A06",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:windriver:linux:-:*:*:*:cd:*:*:*",
                  "matchCriteriaId": "1662CB7A-B0E8-4D57-AEE4-2115F682D2BE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:windriver:linux:17.0:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "7B99877A-BCA1-49D0-99E6-F95409821B5E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:windriver:linux:18.0:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "6F7913BB-308B-47B0-80FC-F820784843EB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:windriver:linux:19.0:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "67613657-08D6-4CBF-AAF4-9355054D24C4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
                  "versionEndIncluding": "8.13.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_agent:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB8B7710-2558-4153-B018-55943E10CBE0",
                  "versionEndIncluding": "8.2.3",
                  "versionStartIncluding": "8.2.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:commerce_guided_search:11.3.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2A3622F5-5976-4BBC-A147-FC8A6431EA79",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
                  "versionEndExcluding": "9.2.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_enterprise_monitor:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F48F2267-61EA-4F12-ADE9-85CB6F6B290E",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
                  "versionEndIncluding": "5.7.33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
                  "versionEndIncluding": "8.0.23",
                  "versionStartIncluding": "8.0.15",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "73DC7DDB-3405-4734-9A8E-7E1D4646CDEF",
                  "versionEndIncluding": "8.59",
                  "versionStartIncluding": "8.57",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
                  "versionEndExcluding": "18.1.0.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:weblogic_server:12.2.1.4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A5BB153-68E0-4DDA-87D1-0D9AB7F0A418",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:weblogic_server:14.1.1.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04BCDC24-4A21-473C-8733-0D9CFB38A752",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1F6C5D7-AEC1-4792-BBA7-A83542430E1A",
                  "versionEndExcluding": "10.2.1.0-17sv",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:sonicwall:capture_client:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1F7545BE-AB25-4BB7-8091-8D03BBD910A6",
                  "versionEndExcluding": "3.6.24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:sonicwall:email_security:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F0B75C3A-7E3A-434A-A045-44A071CB193B",
                  "versionEndExcluding": "10.0.11",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "50478447-8102-4BC4-9E96-3165B20B8BE8",
                  "versionEndIncluding": "7.0.1-r1456",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5C547B5B-8C6D-49AF-90D4-2F6E2F7E512B",
                  "versionEndExcluding": "10.24.1",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3469E4CF-1739-4BE4-B513-4DC771CD2805",
                  "versionEndExcluding": "12.22.1",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "1D2CA9D6-98EE-44B7-9C9D-5A6B55BCA025",
                  "versionEndExcluding": "14.16.1",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
                  "versionEndExcluding": "15.14.0",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a \"purpose\" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named \"purpose\" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)."
        },
        {
          "lang": "es",
          "value": "El flag X509_V_FLAG_X509_STRICT permite llevar a cabo comprobaciones de seguridad adicionales de los certificados presentes en una cadena de certificados. No est\u00e1 establecido por defecto. A partir de la versi\u00f3n 1.1.1h de OpenSSL, se a\u00f1adi\u00f3 como comprobaci\u00f3n estricta adicional la de no permitir certificados en la cadena que tengan par\u00e1metros de curva el\u00edptica codificados expl\u00edcitamente. Un error en la implementaci\u00f3n de esta comprobaci\u00f3n significaba que el resultado de una comprobaci\u00f3n previa para confirmar que los certificados de la cadena son certificados de CA v\u00e1lidos fueron sobrescritos. De este modo, se omite la comprobaci\u00f3n de que los certificados que no son de CA no deben poder emitir otros certificados. Si se ha configurado un \"purpose\", se presenta la posibilidad de comprobar posteriormente que el certificado es una CA v\u00e1lida. Todos los valores de \"purpose\" implementados en libcrypto llevan a cabo esta comprobaci\u00f3n. Por lo tanto, cuando se establece un prop\u00f3sito, la cadena de certificados seguir\u00e1 siendo rechazada inclusive cuando se haya usado el flag strict. Se establece un prop\u00f3sito por defecto en las rutinas de verificaci\u00f3n de certificados de cliente servidor de libssl, pero puede ser anulado o eliminado por una aplicaci\u00f3n. Para que se vea afectada, una aplicaci\u00f3n debe establecer expl\u00edcitamente el flag de verificaci\u00f3n X509_V_FLAG_X509_STRICT y no establecer un prop\u00f3sito para la verificaci\u00f3n de certificados o, en el caso de las aplicaciones de cliente o servidor TLS, anular el prop\u00f3sito por defecto. Este problema afecta a las versiones 1.1.1h y posteriores de OpenSSL. Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k. OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema. Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1h-1.1.1j)"
        }
      ],
      "id": "CVE-2021-3450",
      "lastModified": "2026-10-08T21:17:40.070",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-3450",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:02:24.642640Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-03-25T15:15:13.560",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Vendor Advisory"
          ],
          "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-08"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Vendor Advisory"
          ],
          "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-08"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-295"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2024-26462

    Vulnerability from fkie_nvd - Published: 2024-02-29 01:44 - Updated: 2026-06-17 07:17

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F95920FF-DDA8-4D74-9CFE-81FCD071031D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:management_services_for_element_software_and_netapp_hci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDAC85F0-93AF-4BE3-AE1A-8ADAF1CDF9AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89612649-BACF-4FAC-9BA4-324724FD93A6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3D9B255-C1AF-42D1-BF9B-13642FBDC080",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD7CFE0E-9D1E-4495-B302-89C3096FC0DF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F63A3FA7-AAED-4A9D-9FDE-6195302DA0F6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5921A877-18BF-43FE-915C-D226E140ACFC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7296A1F2-D315-4FD5-8A73-65C480C855BE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/kdc/ndr.c."
        },
        {
          "lang": "es",
          "value": "Kerberos 5 (tambi\u00e9n conocido como krb5) 1.21.2 contiene una vulnerabilidad de p\u00e9rdida de memoria en /krb5/src/kdc/ndr.c."
        }
      ],
      "id": "CVE-2024-26462",
      "lastModified": "2026-06-17T07:17:41.193",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-26462",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-25T20:04:17.090842Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-29T01:44:18.857",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-401"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-401"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-26461

    Vulnerability from fkie_nvd - Published: 2024-02-29 01:44 - Updated: 2026-06-17 07:17

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "kerberos_5",
              "vendor": "mit",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.21.2"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F95920FF-DDA8-4D74-9CFE-81FCD071031D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:management_services_for_element_software_and_netapp_hci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDAC85F0-93AF-4BE3-AE1A-8ADAF1CDF9AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_9:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD886814-B4A0-4764-9F08-2060601D8E89",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89612649-BACF-4FAC-9BA4-324724FD93A6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3D9B255-C1AF-42D1-BF9B-13642FBDC080",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD7CFE0E-9D1E-4495-B302-89C3096FC0DF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F63A3FA7-AAED-4A9D-9FDE-6195302DA0F6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5921A877-18BF-43FE-915C-D226E140ACFC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7296A1F2-D315-4FD5-8A73-65C480C855BE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c."
        },
        {
          "lang": "es",
          "value": "Kerberos 5 (tambi\u00e9n conocido como krb5) 1.21.2 contiene una vulnerabilidad de p\u00e9rdida de memoria en /krb5/src/lib/gssapi/krb5/k5sealv3.c."
        }
      ],
      "id": "CVE-2024-26461",
      "lastModified": "2026-06-17T07:17:41.003",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-26461",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-08-14T15:09:48.143388Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-29T01:44:18.820",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-26458

    Vulnerability from fkie_nvd - Published: 2024-02-29 01:44 - Updated: 2026-06-17 07:17

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F95920FF-DDA8-4D74-9CFE-81FCD071031D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:management_services_for_element_software_and_netapp_hci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDAC85F0-93AF-4BE3-AE1A-8ADAF1CDF9AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_9:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD886814-B4A0-4764-9F08-2060601D8E89",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89612649-BACF-4FAC-9BA4-324724FD93A6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3D9B255-C1AF-42D1-BF9B-13642FBDC080",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD7CFE0E-9D1E-4495-B302-89C3096FC0DF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F63A3FA7-AAED-4A9D-9FDE-6195302DA0F6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5921A877-18BF-43FE-915C-D226E140ACFC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7296A1F2-D315-4FD5-8A73-65C480C855BE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c."
        },
        {
          "lang": "es",
          "value": "Kerberos 5 (tambi\u00e9n conocido como krb5) 1.21.2 contiene una p\u00e9rdida de memoria en /krb5/src/lib/rpc/pmap_rmt.c."
        }
      ],
      "id": "CVE-2024-26458",
      "lastModified": "2026-06-17T07:17:40.823",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-26458",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-02-29T20:47:58.786706Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-29T01:44:18.780",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-401"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-1678

    Vulnerability from fkie_nvd - Published: 2022-05-25 15:15 - Updated: 2026-06-17 04:22
    Summary
    An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients.
    References
    security@openanolis.orghttps://anas.openanolis.cn/cves/detail/CVE-2022-1678Third Party Advisory
    security@openanolis.orghttps://anas.openanolis.cn/errata/detail/ANSA-2022:0143Third Party Advisory
    security@openanolis.orghttps://bugzilla.openanolis.cn/show_bug.cgi?id=61Issue Tracking, Patch, Third Party Advisory
    security@openanolis.orghttps://gitee.com/anolis/cloud-kernel/commit/bed537da691bPermissions Required
    security@openanolis.orghttps://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25aPatch, Third Party Advisory
    security@openanolis.orghttps://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/
    security@openanolis.orghttps://security.netapp.com/advisory/ntap-20220715-0001/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://anas.openanolis.cn/cves/detail/CVE-2022-1678Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://anas.openanolis.cn/errata/detail/ANSA-2022:0143Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://bugzilla.openanolis.cn/show_bug.cgi?id=61Issue Tracking, Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://gitee.com/anolis/cloud-kernel/commit/bed537da691bPermissions Required
    af854a3a-2127-422b-91ae-364da2661108https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25aPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20220715-0001/Third Party Advisory

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "kernel",
              "vendor": "n/a",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "4.18",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "4.19",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "security@openanolis.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B2A2E0DA-9949-495C-AC30-A21F364D71E1",
                  "versionEndIncluding": "4.19",
                  "versionStartIncluding": "4.18",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_santricity_os_controller:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0DA944C-4992-424D-BC82-474585DAC5DF",
                  "versionEndIncluding": "11.70.2",
                  "versionStartIncluding": "11.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:element_software:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "85DF4B3F-4BBC-42B7-B729-096934523D63",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:hci_management_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A3C19813-E823-456A-B1CE-EC0684CE1953",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:solidfire:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A6E9EF0C-AFA8-4F7B-9FDC-1E0F7C26E737",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95BA156C-C977-4F0C-8DFB-3FAE9CC8C02D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD7447BC-F315-4298-A822-549942FC118B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6770B6C3-732E-4E22-BF1C-2D2FD610061C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F9C8C20-42EB-4AB5-BD97-212DEB070C43",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7FFF7106-ED78-49BA-9EC5-B889E3685D53",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E63D8B0F-006E-4801-BF9D-1C001BBFB4F9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "56409CEC-5A1E-4450-AA42-641E459CC2AF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B06F4839-D16A-4A61-9BB5-55B13F41E47F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "108A2215-50FB-4074-94CF-C130FA14566D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h300e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7AFC73CE-ABB9-42D3-9A71-3F5BC5381E0E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32F0B6C0-F930-480D-962B-3F4EFDCC13C7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h500e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "803BC414-B250-4E3A-A478-A3881340D6B8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FEB3337-BFDE-462A-908B-176F92053CEC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h700e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "736AEAE9-782B-4F71-9893-DED53367E102",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0B4AD8A-F172-4558-AEC6-FF424BA2D912",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8497A4C9-8474-4A62-8331-3FE862ED4098",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "234DEFE0-5CE5-4B0A-96B8-5D227CB8ED31",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDDF61B7-EC5C-467C-B710-B89F502CD04F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients."
        },
        {
          "lang": "es",
          "value": "Se ha detectado un problema en el Kernel de Linux de la 4.18 a 4.19, una actualizaci\u00f3n inapropiada de la referencia sock en el paso TCP puede conllevar a una p\u00e9rdida de memoria/netns, que puede ser usada por clientes remotos"
        }
      ],
      "id": "CVE-2022-1678",
      "lastModified": "2026-06-17T04:22:54.573",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "security@openanolis.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-05-25T15:15:07.887",
      "references": [
        {
          "source": "security@openanolis.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
        },
        {
          "source": "security@openanolis.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
        },
        {
          "source": "security@openanolis.org",
          "tags": [
            "Issue Tracking",
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
        },
        {
          "source": "security@openanolis.org",
          "tags": [
            "Permissions Required"
          ],
          "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
        },
        {
          "source": "security@openanolis.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
        },
        {
          "source": "security@openanolis.org",
          "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
        },
        {
          "source": "security@openanolis.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required"
          ],
          "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
        }
      ],
      "sourceIdentifier": "security@openanolis.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-911"
            }
          ],
          "source": "security@openanolis.org",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-36516

    Vulnerability from fkie_nvd - Published: 2022-02-26 04:15 - Updated: 2026-06-17 03:15

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDB8BD32-CDED-49F6-9973-4CE2DC1F79A4",
                  "versionEndIncluding": "5.6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_santricity_os_controller:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "020C93EF-D94B-43CC-9F92-65F046D7EC19",
                  "versionStartIncluding": "11.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:solidfire\\,_enterprise_sds_\\\u0026_hci_storage_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DAA3919C-B2B1-4CB5-BA76-7A079AAFFC52",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:solidfire_\\\u0026_hci_management_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6D700C5-F67F-4FFB-BE69-D524592A3D2E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6770B6C3-732E-4E22-BF1C-2D2FD610061C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F9C8C20-42EB-4AB5-BD97-212DEB070C43",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7FFF7106-ED78-49BA-9EC5-B889E3685D53",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E63D8B0F-006E-4801-BF9D-1C001BBFB4F9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "56409CEC-5A1E-4450-AA42-641E459CC2AF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B06F4839-D16A-4A61-9BB5-55B13F41E47F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "108A2215-50FB-4074-94CF-C130FA14566D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h300e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7AFC73CE-ABB9-42D3-9A71-3F5BC5381E0E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32F0B6C0-F930-480D-962B-3F4EFDCC13C7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h500e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "803BC414-B250-4E3A-A478-A3881340D6B8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FEB3337-BFDE-462A-908B-176F92053CEC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h700e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "736AEAE9-782B-4F71-9893-DED53367E102",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0B4AD8A-F172-4558-AEC6-FF424BA2D912",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8497A4C9-8474-4A62-8331-3FE862ED4098",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "234DEFE0-5CE5-4B0A-96B8-5D227CB8ED31",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDDF61B7-EC5C-467C-B710-B89F502CD04F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89612649-BACF-4FAC-9BA4-324724FD93A6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3D9B255-C1AF-42D1-BF9B-13642FBDC080",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5921A877-18BF-43FE-915C-D226E140ACFC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7296A1F2-D315-4FD5-8A73-65C480C855BE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD7CFE0E-9D1E-4495-B302-89C3096FC0DF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F63A3FA7-AAED-4A9D-9FDE-6195302DA0F6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95BA156C-C977-4F0C-8DFB-3FAE9CC8C02D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD7447BC-F315-4298-A822-549942FC118B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim\u0027s TCP session or terminate that session."
        },
        {
          "lang": "es",
          "value": "Se ha detectado un problema en el kernel de Linux versiones hasta 5.16.11. El m\u00e9todo de asignaci\u00f3n de IPID mixto con la pol\u00edtica de asignaci\u00f3n de IPID basada en hash permite a un atacante fuera de la ruta inyectar datos en la sesi\u00f3n TCP de una v\u00edctima o terminar esa sesi\u00f3n."
        }
      ],
      "id": "CVE-2020-36516",
      "lastModified": "2026-06-17T03:15:37.927",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.9,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 1.6,
            "impactScore": 4.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-02-26T04:15:06.933",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Technical Description",
            "Third Party Advisory"
          ],
          "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Technical Description",
            "Third Party Advisory"
          ],
          "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-327"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-16166

    Vulnerability from fkie_nvd - Published: 2020-07-30 21:15 - Updated: 2026-06-17 02:57
    Summary
    The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c.
    References
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.htmlMailing List, Third Party Advisory
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://arxiv.org/pdf/2012.07432.pdfTechnical Description, Third Party Advisory
    cve@mitre.orghttps://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4Patch, Vendor Advisory
    cve@mitre.orghttps://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638Patch, Vendor Advisory
    cve@mitre.orghttps://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4Patch, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/09/msg00025.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/10/msg00032.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/10/msg00034.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/
    cve@mitre.orghttps://security.netapp.com/advisory/ntap-20200814-0004/Third Party Advisory
    cve@mitre.orghttps://usn.ubuntu.com/4525-1/Third Party Advisory
    cve@mitre.orghttps://usn.ubuntu.com/4526-1/Third Party Advisory
    cve@mitre.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://arxiv.org/pdf/2012.07432.pdfTechnical Description, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4Patch, Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638Patch, Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/09/msg00025.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/10/msg00032.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/10/msg00034.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20200814-0004/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://usn.ubuntu.com/4525-1/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://usn.ubuntu.com/4526-1/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F999DECE-5A01-4DCC-9FE0-EFA5001598EE",
                  "versionEndIncluding": "5.7.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:opensuse:leap:15.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B620311B-34A3-48A6-82DF-6F078D7A4493",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:opensuse:leap:15.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B009C22E-30A4-4288-BCF6-C3E81DEAF45A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:31:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80F0FA5D-8D3B-4C0E-81E2-87998286AF33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:32:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36D96259-24BD-44E2-96D9-78CE1D41F956",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm:*:*:*",
                  "matchCriteriaId": "815D70A8-47D3-459C-A32C-9FEACA0659D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "902B8056-9E37-443B-8905-8AA93E2447FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:*:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "0CB28AF5-5AF0-4475-A7B6-12E1795FFDCB",
                  "versionStartIncluding": "9.5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_santricity_os_controller:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD1E9594-C46F-40D1-8BC2-6B16635B55C4",
                  "versionEndIncluding": "11.60.3",
                  "versionStartIncluding": "11.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:hci_bootstrap_os:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "84574629-EB00-4235-8962-45070F3C9F6A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:hci_management_node:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A3C19813-E823-456A-B1CE-EC0684CE1953",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:solidfire:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A6E9EF0C-AFA8-4F7B-9FDC-1E0F7C26E737",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:steelstore_cloud_integrated_storage:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E94F7F59-1785-493F-91A7-5F5EA5E87E4D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "73019FE2-F7CE-4B12-9DC1-8333F08A7D9C",
                  "versionEndIncluding": "9.0.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "234DEFE0-5CE5-4B0A-96B8-5D227CB8ED31",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDDF61B7-EC5C-467C-B710-B89F502CD04F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:sd-wan_edge:8.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "78C99571-0F3C-43E6-84B3-7D80E045EF8E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c."
        },
        {
          "lang": "es",
          "value": "El kernel de Linux versiones hasta 5.7.11, permite a atacantes remotos realizar observaciones que ayudan a obtener informaci\u00f3n confidencial sobre el estado interno de la red RNG, tambi\u00e9n se conoce como CID-f227e3ec3b5c. Esto est\u00e1 relacionado con los archivos drivers/char/random.c y kernel/time/timer.c"
        }
      ],
      "id": "CVE-2020-16166",
      "lastModified": "2026-06-17T02:57:49.130",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 3.7,
              "baseSeverity": "LOW",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-07-30T21:15:11.533",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Technical Description",
            "Third Party Advisory"
          ],
          "url": "https://arxiv.org/pdf/2012.07432.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4525-1/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4526-1/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Technical Description",
            "Third Party Advisory"
          ],
          "url": "https://arxiv.org/pdf/2012.07432.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4525-1/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4526-1/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-330"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2024-26462 (GCVE-0-2024-26462)

    Vulnerability from nvd – Published: 2024-02-26 00:00 – Updated: 2025-03-25 20:05
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/kdc/ndr.c.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-25 20:04 UTC
    CWE
    • n/a
    • CWE-401 - Missing Release of Memory after Effective Lifetime
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 5.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26462",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-25T20:04:17.090842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-401",
                    "description": "CWE-401 Missing Release of Memory after Effective Lifetime",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T20:05:04.705Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/kdc/ndr.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:05.191Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26462",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2025-03-25T20:05:04.705Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-26461 (GCVE-0-2024-26461)

    Vulnerability from nvd – Published: 2024-02-26 00:00 – Updated: 2024-08-14 15:15
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-14 15:09 UTC
    CWE
    • n/a
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Impacted products
    Vendor Product Version
    mit kerberos_5 Affected: 1.21.2
        cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.361Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "kerberos_5",
                "vendor": "mit",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.21.2"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26461",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T15:09:48.143388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-770",
                    "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-14T15:15:42.206Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:17.596Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26461",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2024-08-14T15:15:42.206Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-26458 (GCVE-0-2024-26458)

    Vulnerability from nvd – Published: 2024-02-26 00:00 – Updated: 2024-12-06 21:01
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-02-29 20:47 UTC
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26458",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-29T20:47:58.786706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-06T21:01:53.155Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.467Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:14.610Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26458",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2024-12-06T21:01:53.155Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-1678 (GCVE-0-2022-1678)

    Vulnerability from nvd – Published: 2022-05-25 14:49 – Updated: 2024-08-03 00:10
    VLAI
    Summary
    An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients.
    CWE
    • CWE-911 - Improper Update of Reference Count
    Assigner
    Anolis CNA under the mitre root
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    n/a kernel Affected: 4.18 , < unspecified (custom)
    Affected: unspecified , ≤ 4.19 (custom)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:10:03.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "kernel",
              "vendor": "n/a",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "4.18",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "4.19",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-911",
                  "description": "CWE-911 Improper Update of Reference Count",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-15T15:06:58.000Z",
            "orgId": "cb8f1db9-b4b1-487b-a760-f65c4f368d8e",
            "shortName": "Anolis"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "security@openanolis.org",
              "ID": "CVE-2022-1678",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "kernel",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "4.18"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.19"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients."
                }
              ]
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-911 Improper Update of Reference Count"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61",
                  "refsource": "CONFIRM",
                  "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
                },
                {
                  "name": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing@gmail.com/",
                  "refsource": "MISC",
                  "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing@gmail.com/"
                },
                {
                  "name": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a",
                  "refsource": "MISC",
                  "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
                },
                {
                  "name": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b",
                  "refsource": "MISC",
                  "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
                },
                {
                  "name": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678",
                  "refsource": "MISC",
                  "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
                },
                {
                  "name": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143",
                  "refsource": "MISC",
                  "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220715-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cb8f1db9-b4b1-487b-a760-f65c4f368d8e",
        "assignerShortName": "Anolis",
        "cveId": "CVE-2022-1678",
        "datePublished": "2022-05-25T14:49:30.000Z",
        "dateReserved": "2022-05-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T00:10:03.820Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0778 (GCVE-0-2022-0778)

    Vulnerability from nvd – Published: 2022-03-15 17:05 – Updated: 2026-10-14 12:12
    VLAI
    Title
    Infinite loop in BN_mod_sqrt() reachable when parsing certificates
    Summary
    The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-22 13:27 UTC
    CWE
    • Infinite loop
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20220315.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://www.debian.org/security/2022/dsa-5103 vendor-advisory
    https://lists.debian.org/debian-lts-announce/2022… mailing-list
    https://lists.debian.org/debian-lts-announce/2022… mailing-list
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://security.netapp.com/advisory/ntap-2022032…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://www.tenable.com/security/tns-2022-06
    https://www.tenable.com/security/tns-2022-07
    https://www.tenable.com/security/tns-2022-08
    http://seclists.org/fulldisclosure/2022/May/33 mailing-list
    http://seclists.org/fulldisclosure/2022/May/35 mailing-list
    http://seclists.org/fulldisclosure/2022/May/38 mailing-list
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://support.apple.com/kb/HT213257
    https://support.apple.com/kb/HT213256
    https://support.apple.com/kb/HT213255
    https://www.tenable.com/security/tns-2022-09
    https://security.netapp.com/advisory/ntap-2022042…
    http://packetstormsecurity.com/files/167344/OpenS…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://security.gentoo.org/glsa/202210-02 vendor-advisory
    https://security.netapp.com/advisory/ntap-2024062…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)
    Affected: Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)
    Affected: Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)
    Create a notification for this product.
    Siemens BFCClient Affected: 0 , < V2.17 (custom)
    Create a notification for this product.
    Siemens Industrial Edge - OPC UA Connector Affected: 0 , < V1.7.0.0 (custom)
    Create a notification for this product.
    Siemens Industrial Edge - SIMATIC S7 Connector App Affected: 0 , < V1.7.0.0 (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V8.2 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V9.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V9.1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) EU Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) NAM Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX MX5000 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX MX5000RE Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1400 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1500 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1501 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1510 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1511 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1512 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1524 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1536 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX5000 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9403 Affected: 0 , < V2.0 HF0 (custom)
    Create a notification for this product.
    Siemens SCALANCE M804PB Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M826-2 SHDSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M874-2 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M874-3 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-3 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-3 (ROK) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 (NAM) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM853-1 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM856-1 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM856-1 (RoW) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE S615 EEC LAN-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE S615 LAN-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1748-1 M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (JP) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (ROW) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (USA) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-1 M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-2 EEC M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-2 M12 Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 484 products shown. All of them on the page of CVE-2022-0778.

    Date Public
    2022-03-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.765Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20220315.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
              },
              {
                "name": "DSA-5103",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2022/dsa-5103"
              },
              {
                "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
              },
              {
                "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
              },
              {
                "name": "FEDORA-2022-a5f51502f0",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
              },
              {
                "name": "FEDORA-2022-9e88b5d8d7",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
              },
              {
                "name": "FEDORA-2022-8bb51f6901",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-07"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-08"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/33"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/35"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/38"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213257"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213256"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213255"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
              },
              {
                "name": "GLSA-202210-02",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202210-02"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "BFCClient",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge - OPC UA Connector",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.7.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge - SIMATIC S7 Connector App",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.7.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V8.2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V9.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V9.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM RM1224 LTE(4G) EU",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX MX5000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX MX5000RE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1400",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1501",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1510",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1511",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1524",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1536",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX5000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9403",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0 HF0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M804PB",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M812-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M812-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M816-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M816-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M826-2 SHDSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M874-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M874-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-3 (ROK)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4 (NAM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM853-1 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM856-1 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM856-1 (RoW)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE S615 EEC LAN-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE S615 LAN-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC622-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC632-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC636-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC642-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC646-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (JP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (ROW)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2 EEC M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2IA M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 (US)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 EEC (US)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM766-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM766-1 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X200-4P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X201-3P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X201-3P IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2P IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2FM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2LD TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X206-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X206-1LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X208PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X212-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X212-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X224",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X304-2FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X306-1LD FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2 RD (inkl. SIPLUS variants)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH+",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH+",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X320-1 FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X320-1-2LD FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X408-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3LD (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3LD (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB208 (E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB208 (PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (ST, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3LD (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3LD (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB216 (E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB216 (PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2 (SC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2 (ST/BFOC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G (EIP def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-3G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-3G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G (EIP Def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G (EIP Def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF201-3P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204 DNA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA DNA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF206-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-4C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-8C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-8C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM416-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM416-4C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208 (Ethernet/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208PoE EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216 (Ethernet/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216POE EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M TS (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M TS (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR326-2C PoE WG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR326-2C PoE WG (without UL)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 1x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 24V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 24V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 2x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 1x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 24V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 24V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 2x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Security Configuration Tool (SCT)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Cloud Connect 7 CC712",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.9.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Cloud Connect 7 CC716",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.9.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1242-7 V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-7 LTE EU",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-7 LTE US",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-8 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1542SP-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1543-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.37",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1543SP-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1545-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.1.80",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1626",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1628",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 343-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 443-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 443-1 OPC UA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Drive Controller CPU 1504D TF",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Drive Controller CPU 1507D TF",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC HMI Unified Comfort Panels family",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V18.0 Update 0 SR0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Logon V1.6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.6 Upd6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV540 H",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV540 S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV550 H",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV550 S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV560 U",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV560 X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V14",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V15",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V16 Update 6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 SP1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 TeleControl",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V8.2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V9.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V9.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.1 SP2 UC04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS neo (Administration Console)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PDM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.2 SP2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Process Historian OPC UA Server",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2020 SP1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF166C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF185C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF186C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF186CI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF188C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF188CI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF360R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF610R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF615R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF650R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF680R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF685R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 Software Controller V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-PLCSIM Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.7 HF4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.4 SP1 Update 22",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.5 SP2 Update 16",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.1",
                    "status": "affected",
                    "version": "V5.1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION SCOUT TIA V5.3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION SCOUT TIA V5.4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS DCC V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS DCC V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAUT Software ST7sc",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAUT ST7CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC INS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0 SP2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC NMS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0 SP3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Server",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 1242-7 V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 1543-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.37",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 343-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 443-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE X202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC206-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC206-2SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC216-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CP 1243-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS TIM 1531 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.4.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Safety ES V17 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V15.1 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V16 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TeleControl Server Basic V3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Portal Cloud V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Portal Cloud V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIM 1531 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.4.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-14T12:12:36.346Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-108696.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-028723.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
              }
            ],
            "x_adpType": "supplier"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-22T13:27:14.476267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-835",
                    "description": "CWE-835 Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-22T13:28:08.544Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Tavis Ormandy (Google)"
            }
          ],
          "datePublic": "2022-03-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Infinite loop",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:07:01.186Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20220315.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
            },
            {
              "name": "DSA-5103",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2022/dsa-5103"
            },
            {
              "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
            },
            {
              "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
            },
            {
              "name": "FEDORA-2022-a5f51502f0",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
            },
            {
              "name": "FEDORA-2022-9e88b5d8d7",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
            },
            {
              "name": "FEDORA-2022-8bb51f6901",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-07"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-08"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/33"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/35"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/38"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://support.apple.com/kb/HT213257"
            },
            {
              "url": "https://support.apple.com/kb/HT213256"
            },
            {
              "url": "https://support.apple.com/kb/HT213255"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
            },
            {
              "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
            },
            {
              "name": "GLSA-202210-02",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202210-02"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "Infinite loop in BN_mod_sqrt() reachable when parsing certificates"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2022-0778",
        "datePublished": "2022-03-15T17:05:20.382Z",
        "dateReserved": "2022-02-28T00:00:00.000Z",
        "dateUpdated": "2026-10-14T12:12:36.346Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-36516 (GCVE-0-2020-36516)

    Vulnerability from nvd – Published: 2022-02-26 03:14 – Updated: 2024-08-04 17:30
    VLAI
    Summary
    An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim's TCP session or terminate that session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T17:30:08.304Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim\u0027s TCP session or terminate that session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-31T08:06:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-36516",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim\u0027s TCP session or terminate that session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://dl.acm.org/doi/10.1145/3372297.3417884",
                  "refsource": "MISC",
                  "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220331-0003/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-36516",
        "datePublished": "2022-02-26T03:14:46.000Z",
        "dateReserved": "2022-02-26T00:00:00.000Z",
        "dateUpdated": "2024-08-04T17:30:08.304Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3450 (GCVE-0-2021-3450)

    Vulnerability from nvd – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:03
    VLAI
    Title
    CA certificate check bypass with X509_V_FLAG_X509_STRICT
    Summary
    The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a "purpose" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named "purpose" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:02 UTC
    CWE
    • Invalid Certificate Verification
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt x_refsource_CONFIRM
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba… x_refsource_CONFIRM
    https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-listx_refsource_MLIST
    https://security.gentoo.org/glsa/202103-03 vendor-advisoryx_refsource_GENTOO
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://www.oracle.com/security-alerts/cpuApr2021.html x_refsource_MISC
    https://www.tenable.com/security/tns-2021-09 x_refsource_CONFIRM
    https://security.netapp.com/advisory/ntap-2021032… x_refsource_CONFIRM
    https://security.FreeBSD.org/advisories/FreeBSD-S… x_refsource_MISC
    https://www.tenable.com/security/tns-2021-05 x_refsource_CONFIRM
    https://kc.mcafee.com/corporate/index?page=conten… x_refsource_CONFIRM
    https://www.tenable.com/security/tns-2021-08 x_refsource_CONFIRM
    https://mta.openssl.org/pipermail/openssl-announc… x_refsource_MISC
    https://www.oracle.com//security-alerts/cpujul2021.html x_refsource_MISC
    https://kb.pulsesecure.net/articles/Pulse_Securit… x_refsource_CONFIRM
    https://psirt.global.sonicwall.com/vuln-detail/SN… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/cpuoct2021.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpuapr2022.html x_refsource_MISC
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/cpujul2022.html x_refsource_MISC
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.644Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_CISCO",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_GENTOO",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-08"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:02:24.642640Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:03:32.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Benjamin Kaduk (Akamai), Xiang Ding (Akamai), others at Akamai"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a \"purpose\" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named \"purpose\" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Invalid Certificate Verification",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-25T16:35:11.000Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory",
                "x_refsource_CISCO"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory",
                "x_refsource_GENTOO"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-08"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            }
          ],
          "title": "CA certificate check bypass with X509_V_FLAG_X509_STRICT",
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "openssl-security@openssl.org",
              "DATE_PUBLIC": "2021-03-25",
              "ID": "CVE-2021-3450",
              "STATE": "PUBLIC",
              "TITLE": "CA certificate check bypass with X509_V_FLAG_X509_STRICT"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OpenSSL",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OpenSSL"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Benjamin Kaduk (Akamai), Xiang Ding (Akamai), others at Akamai"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a \"purpose\" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named \"purpose\" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)."
                }
              ]
            },
            "impact": [
              {
                "lang": "eng",
                "url": "https://www.openssl.org/policies/secpolicy.html#High",
                "value": "High"
              }
            ],
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Invalid Certificate Verification"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.openssl.org/news/secadv/20210325.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.openssl.org/news/secadv/20210325.txt"
                },
                {
                  "name": "https://www.openssl.org/news/secadv/20210325.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.openssl.org/news/secadv/20210325.txt"
                },
                {
                  "name": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b",
                  "refsource": "CONFIRM",
                  "url": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
                },
                {
                  "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                  "refsource": "CISCO",
                  "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
                },
                {
                  "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
                },
                {
                  "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
                },
                {
                  "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
                },
                {
                  "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
                },
                {
                  "name": "GLSA-202103-03",
                  "refsource": "GENTOO",
                  "url": "https://security.gentoo.org/glsa/202103-03"
                },
                {
                  "name": "FEDORA-2021-cbf14ab8f9",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuApr2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-09",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-09"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20210326-0006/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
                },
                {
                  "name": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc",
                  "refsource": "MISC",
                  "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-05"
                },
                {
                  "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356",
                  "refsource": "CONFIRM",
                  "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-08",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-08"
                },
                {
                  "name": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html",
                  "refsource": "MISC",
                  "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
                },
                {
                  "name": "https://www.oracle.com//security-alerts/cpujul2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
                },
                {
                  "name": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845",
                  "refsource": "CONFIRM",
                  "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
                },
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuoct2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3450",
        "datePublished": "2021-03-25T14:25:14.287Z",
        "dateReserved": "2021-03-19T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:03:32.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-3449 (GCVE-0-2021-3449)

    Vulnerability from nvd – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:13
    VLAI
    Title
    NULL pointer deref in signature_algorithms processing
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:05 UTC
    CWE
    • NULL pointer dereference
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    https://www.debian.org/security/2021/dsa-4875 vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-list
    https://security.gentoo.org/glsa/202103-03 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuApr2021.html
    https://www.tenable.com/security/tns-2021-10
    https://www.tenable.com/security/tns-2021-09
    https://security.netapp.com/advisory/ntap-2021051…
    https://security.netapp.com/advisory/ntap-2021032…
    https://security.FreeBSD.org/advisories/FreeBSD-S…
    https://www.tenable.com/security/tns-2021-06
    https://www.tenable.com/security/tns-2021-05
    https://kc.mcafee.com/corporate/index?page=conten…
    https://www.oracle.com//security-alerts/cpujul2021.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://kb.pulsesecure.net/articles/Pulse_Securit…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://www.oracle.com/security-alerts/cpuoct2021.html
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://security.netapp.com/advisory/ntap-2024062…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.609Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "DSA-4875",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-4875"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-10"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:05:43.522199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:13:50.095Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL pointer dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:05:57.096Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "DSA-4875",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-4875"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-10"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
            },
            {
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "NULL pointer deref in signature_algorithms processing"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3449",
        "datePublished": "2021-03-25T14:25:13.659Z",
        "dateReserved": "2021-03-17T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:13:50.095Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-16166 (GCVE-0-2020-16166)

    Vulnerability from nvd – Published: 2020-07-30 20:05 – Updated: 2024-08-04 13:37
    VLAI
    Summary
    The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T13:37:53.889Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
              },
              {
                "name": "openSUSE-SU-2020:1153",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
              },
              {
                "name": "FEDORA-2020-8d634e31c0",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
              },
              {
                "name": "FEDORA-2020-2cd6393548",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
              },
              {
                "name": "openSUSE-SU-2020:1236",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
              },
              {
                "name": "USN-4526-1",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_UBUNTU",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4526-1/"
              },
              {
                "name": "USN-4525-1",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_UBUNTU",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4525-1/"
              },
              {
                "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
              },
              {
                "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
              },
              {
                "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2012.07432.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-14T17:20:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
            },
            {
              "name": "openSUSE-SU-2020:1153",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
            },
            {
              "name": "FEDORA-2020-8d634e31c0",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
            },
            {
              "name": "FEDORA-2020-2cd6393548",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
            },
            {
              "name": "openSUSE-SU-2020:1236",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
            },
            {
              "name": "USN-4526-1",
              "tags": [
                "vendor-advisory",
                "x_refsource_UBUNTU"
              ],
              "url": "https://usn.ubuntu.com/4526-1/"
            },
            {
              "name": "USN-4525-1",
              "tags": [
                "vendor-advisory",
                "x_refsource_UBUNTU"
              ],
              "url": "https://usn.ubuntu.com/4525-1/"
            },
            {
              "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
            },
            {
              "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
            },
            {
              "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://arxiv.org/pdf/2012.07432.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-16166",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4",
                  "refsource": "MISC",
                  "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
                },
                {
                  "name": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4",
                  "refsource": "MISC",
                  "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
                },
                {
                  "name": "openSUSE-SU-2020:1153",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
                },
                {
                  "name": "FEDORA-2020-8d634e31c0",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
                },
                {
                  "name": "FEDORA-2020-2cd6393548",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
                },
                {
                  "name": "openSUSE-SU-2020:1236",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
                },
                {
                  "name": "USN-4526-1",
                  "refsource": "UBUNTU",
                  "url": "https://usn.ubuntu.com/4526-1/"
                },
                {
                  "name": "USN-4525-1",
                  "refsource": "UBUNTU",
                  "url": "https://usn.ubuntu.com/4525-1/"
                },
                {
                  "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
                },
                {
                  "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
                },
                {
                  "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuApr2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20200814-0004/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
                },
                {
                  "name": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638",
                  "refsource": "MISC",
                  "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
                },
                {
                  "name": "https://arxiv.org/pdf/2012.07432.pdf",
                  "refsource": "MISC",
                  "url": "https://arxiv.org/pdf/2012.07432.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-16166",
        "datePublished": "2020-07-30T20:05:24.000Z",
        "dateReserved": "2020-07-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T13:37:53.889Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20907 (GCVE-0-2019-20907)

    Vulnerability from nvd – Published: 2020-07-13 00:00 – Updated: 2026-10-14 07:57
    VLAI
    Summary
    In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-07 17:58 UTC
    CWE
    • n/a
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    URL Tags
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://usn.ubuntu.com/4428-1/ vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://security.gentoo.org/glsa/202008-01 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.debian.org/debian-lts-announce/2020… mailing-list
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.debian.org/debian-lts-announce/2020… mailing-list
    https://www.oracle.com/security-alerts/cpujan2021.html
    https://bugs.python.org/issue39017
    https://github.com/python/cpython/pull/21454
    https://security.netapp.com/advisory/ntap-2020073…
    https://lists.debian.org/debian-lts-announce/2023… mailing-list
    https://cert-portal.siemens.com/productcert/html/…
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:53:09.456Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "FEDORA-2020-dfb11916cc",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
              },
              {
                "name": "FEDORA-2020-e9251de272",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
              },
              {
                "name": "USN-4428-1",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4428-1/"
              },
              {
                "name": "FEDORA-2020-c3b07cc5c9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
              },
              {
                "name": "FEDORA-2020-aab24d3714",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
              },
              {
                "name": "FEDORA-2020-bb919e575e",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
              },
              {
                "name": "FEDORA-2020-97d775e649",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
              },
              {
                "name": "GLSA-202008-01",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202008-01"
              },
              {
                "name": "FEDORA-2020-826b24c329",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
              },
              {
                "name": "FEDORA-2020-1ddd5273d6",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
              },
              {
                "name": "FEDORA-2020-87c0a0a52d",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
              },
              {
                "name": "FEDORA-2020-efb908b6a8",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
              },
              {
                "name": "FEDORA-2020-d808fdd597",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
              },
              {
                "name": "FEDORA-2020-982b2950db",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
              },
              {
                "name": "FEDORA-2020-c539babb0a",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
              },
              {
                "name": "[debian-lts-announce] 20200822 [SECURITY] [DLA 2337-1] python2.7 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
              },
              {
                "name": "openSUSE-SU-2020:1254",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
              },
              {
                "name": "openSUSE-SU-2020:1257",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
              },
              {
                "name": "openSUSE-SU-2020:1258",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
              },
              {
                "name": "openSUSE-SU-2020:1265",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
              },
              {
                "name": "FEDORA-2020-d30881c970",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
              },
              {
                "name": "[debian-lts-announce] 20201119 [SECURITY] [DLA 2456-1] python3.5 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://bugs.python.org/issue39017"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/python/cpython/pull/21454"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
              },
              {
                "name": "[debian-lts-announce] 20230524 [SECURITY] [DLA 3432-1] python2.7 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 5.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-20907",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-07T17:58:36.334729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-835",
                    "description": "CWE-835 Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-07T17:59:38.830Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-14T07:57:15.074Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-24T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "FEDORA-2020-dfb11916cc",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
            },
            {
              "name": "FEDORA-2020-e9251de272",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
            },
            {
              "name": "USN-4428-1",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://usn.ubuntu.com/4428-1/"
            },
            {
              "name": "FEDORA-2020-c3b07cc5c9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
            },
            {
              "name": "FEDORA-2020-aab24d3714",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
            },
            {
              "name": "FEDORA-2020-bb919e575e",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
            },
            {
              "name": "FEDORA-2020-97d775e649",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
            },
            {
              "name": "GLSA-202008-01",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202008-01"
            },
            {
              "name": "FEDORA-2020-826b24c329",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
            },
            {
              "name": "FEDORA-2020-1ddd5273d6",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
            },
            {
              "name": "FEDORA-2020-87c0a0a52d",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
            },
            {
              "name": "FEDORA-2020-efb908b6a8",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
            },
            {
              "name": "FEDORA-2020-d808fdd597",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
            },
            {
              "name": "FEDORA-2020-982b2950db",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
            },
            {
              "name": "FEDORA-2020-c539babb0a",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
            },
            {
              "name": "[debian-lts-announce] 20200822 [SECURITY] [DLA 2337-1] python2.7 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
            },
            {
              "name": "openSUSE-SU-2020:1254",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
            },
            {
              "name": "openSUSE-SU-2020:1257",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
            },
            {
              "name": "openSUSE-SU-2020:1258",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
            },
            {
              "name": "openSUSE-SU-2020:1265",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
            },
            {
              "name": "FEDORA-2020-d30881c970",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
            },
            {
              "name": "[debian-lts-announce] 20201119 [SECURITY] [DLA 2456-1] python3.5 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
            },
            {
              "url": "https://bugs.python.org/issue39017"
            },
            {
              "url": "https://github.com/python/cpython/pull/21454"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
            },
            {
              "name": "[debian-lts-announce] 20230524 [SECURITY] [DLA 3432-1] python2.7 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20907",
        "datePublished": "2020-07-13T00:00:00.000Z",
        "dateReserved": "2020-07-13T00:00:00.000Z",
        "dateUpdated": "2026-10-14T07:57:15.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-26461 (GCVE-0-2024-26461)

    Vulnerability from cvelistv5 – Published: 2024-02-26 00:00 – Updated: 2024-08-14 15:15
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-14 15:09 UTC
    CWE
    • n/a
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Impacted products
    Vendor Product Version
    mit kerberos_5 Affected: 1.21.2
        cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.361Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mit:kerberos_5:1.21.2:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "kerberos_5",
                "vendor": "mit",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.21.2"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26461",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T15:09:48.143388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-770",
                    "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-14T15:15:42.206Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:17.596Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_2.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0011/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26461",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2024-08-14T15:15:42.206Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-26462 (GCVE-0-2024-26462)

    Vulnerability from cvelistv5 – Published: 2024-02-26 00:00 – Updated: 2025-03-25 20:05
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/kdc/ndr.c.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-25 20:04 UTC
    CWE
    • n/a
    • CWE-401 - Missing Release of Memory after Effective Lifetime
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 5.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26462",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-25T20:04:17.090842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-401",
                    "description": "CWE-401 Missing Release of Memory after Effective Lifetime",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T20:05:04.705Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/kdc/ndr.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:05.191Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_3.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0012/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26462",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2025-03-25T20:05:04.705Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-26458 (GCVE-0-2024-26458)

    Vulnerability from cvelistv5 – Published: 2024-02-26 00:00 – Updated: 2024-12-06 21:01
    VLAI
    Summary
    Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-02-29 20:47 UTC
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-26458",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-29T20:47:58.786706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-06T21:01:53.155Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:07:19.467Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T15:06:14.610Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LuMingYinDetect/krb5_defects/blob/main/krb5_detect_1.md"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240415-0010/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-26458",
        "datePublished": "2024-02-26T00:00:00.000Z",
        "dateReserved": "2024-02-19T00:00:00.000Z",
        "dateUpdated": "2024-12-06T21:01:53.155Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-1678 (GCVE-0-2022-1678)

    Vulnerability from cvelistv5 – Published: 2022-05-25 14:49 – Updated: 2024-08-03 00:10
    VLAI
    Summary
    An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients.
    CWE
    • CWE-911 - Improper Update of Reference Count
    Assigner
    Anolis CNA under the mitre root
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    n/a kernel Affected: 4.18 , < unspecified (custom)
    Affected: unspecified , ≤ 4.19 (custom)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:10:03.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "kernel",
              "vendor": "n/a",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "4.18",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "4.19",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-911",
                  "description": "CWE-911 Improper Update of Reference Count",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-15T15:06:58.000Z",
            "orgId": "cb8f1db9-b4b1-487b-a760-f65c4f368d8e",
            "shortName": "Anolis"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing%40gmail.com/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "security@openanolis.org",
              "ID": "CVE-2022-1678",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "kernel",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "4.18"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "4.19"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in the Linux Kernel from 4.18 to 4.19, an improper update of sock reference in TCP pacing can lead to memory/netns leak, which can be used by remote clients."
                }
              ]
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-911 Improper Update of Reference Count"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61",
                  "refsource": "CONFIRM",
                  "url": "https://bugzilla.openanolis.cn/show_bug.cgi?id=61"
                },
                {
                  "name": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing@gmail.com/",
                  "refsource": "MISC",
                  "url": "https://lore.kernel.org/all/20200602080425.93712-1-kerneljasonxing@gmail.com/"
                },
                {
                  "name": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a",
                  "refsource": "MISC",
                  "url": "https://github.com/torvalds/linux/commit/0a70f118475e037732557796accd0878a00fc25a"
                },
                {
                  "name": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b",
                  "refsource": "MISC",
                  "url": "https://gitee.com/anolis/cloud-kernel/commit/bed537da691b"
                },
                {
                  "name": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678",
                  "refsource": "MISC",
                  "url": "https://anas.openanolis.cn/cves/detail/CVE-2022-1678"
                },
                {
                  "name": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143",
                  "refsource": "MISC",
                  "url": "https://anas.openanolis.cn/errata/detail/ANSA-2022:0143"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220715-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220715-0001/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cb8f1db9-b4b1-487b-a760-f65c4f368d8e",
        "assignerShortName": "Anolis",
        "cveId": "CVE-2022-1678",
        "datePublished": "2022-05-25T14:49:30.000Z",
        "dateReserved": "2022-05-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T00:10:03.820Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0778 (GCVE-0-2022-0778)

    Vulnerability from cvelistv5 – Published: 2022-03-15 17:05 – Updated: 2026-10-14 12:12
    VLAI
    Title
    Infinite loop in BN_mod_sqrt() reachable when parsing certificates
    Summary
    The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-22 13:27 UTC
    CWE
    • Infinite loop
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20220315.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://www.debian.org/security/2022/dsa-5103 vendor-advisory
    https://lists.debian.org/debian-lts-announce/2022… mailing-list
    https://lists.debian.org/debian-lts-announce/2022… mailing-list
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://security.netapp.com/advisory/ntap-2022032…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://www.tenable.com/security/tns-2022-06
    https://www.tenable.com/security/tns-2022-07
    https://www.tenable.com/security/tns-2022-08
    http://seclists.org/fulldisclosure/2022/May/33 mailing-list
    http://seclists.org/fulldisclosure/2022/May/35 mailing-list
    http://seclists.org/fulldisclosure/2022/May/38 mailing-list
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://support.apple.com/kb/HT213257
    https://support.apple.com/kb/HT213256
    https://support.apple.com/kb/HT213255
    https://www.tenable.com/security/tns-2022-09
    https://security.netapp.com/advisory/ntap-2022042…
    http://packetstormsecurity.com/files/167344/OpenS…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://security.gentoo.org/glsa/202210-02 vendor-advisory
    https://security.netapp.com/advisory/ntap-2024062…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    https://cert-portal.siemens.com/productcert/html/…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)
    Affected: Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)
    Affected: Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)
    Create a notification for this product.
    Siemens BFCClient Affected: 0 , < V2.17 (custom)
    Create a notification for this product.
    Siemens Industrial Edge - OPC UA Connector Affected: 0 , < V1.7.0.0 (custom)
    Create a notification for this product.
    Siemens Industrial Edge - SIMATIC S7 Connector App Affected: 0 , < V1.7.0.0 (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V8.2 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V9.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens OpenPCS 7 V9.1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) EU Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) NAM Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX MX5000 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX MX5000RE Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1400 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1500 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1501 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1510 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1511 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1512 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1524 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX1536 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM ROX RX5000 Affected: 0 , < V2.15.1 (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9403 Affected: 0 , < V2.0 HF0 (custom)
    Create a notification for this product.
    Siemens SCALANCE M804PB Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M826-2 SHDSL-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M874-2 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M874-3 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-3 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-3 (ROK) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE M876-4 (NAM) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM853-1 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM856-1 (EU) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE MUM856-1 (RoW) Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE S615 EEC LAN-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE S615 LAN-Router Affected: 0 , < V7.2 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3.1.0 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1748-1 M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (JP) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (ROW) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1750D (USA) Affected: 0 , < V8.7.1.11 (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-1 M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-2 EEC M12 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE W1788-2 M12 Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 484 products shown. All of them on the page of CVE-2022-0778.

    Date Public
    2022-03-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.765Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20220315.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
              },
              {
                "name": "DSA-5103",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2022/dsa-5103"
              },
              {
                "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
              },
              {
                "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
              },
              {
                "name": "FEDORA-2022-a5f51502f0",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
              },
              {
                "name": "FEDORA-2022-9e88b5d8d7",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
              },
              {
                "name": "FEDORA-2022-8bb51f6901",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-07"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-08"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/33"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/35"
              },
              {
                "name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/May/38"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213257"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213256"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213255"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2022-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
              },
              {
                "name": "GLSA-202210-02",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202210-02"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "BFCClient",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge - OPC UA Connector",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.7.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge - SIMATIC S7 Connector App",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.7.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V8.2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V9.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "OpenPCS 7 V9.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM RM1224 LTE(4G) EU",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX MX5000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX MX5000RE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1400",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1501",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1510",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1511",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1524",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX1536",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM ROX RX5000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9403",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0 HF0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M804PB",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M812-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M812-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M816-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M816-1 ADSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M826-2 SHDSL-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M874-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M874-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-3 (ROK)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE M876-4 (NAM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM853-1 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM856-1 (EU)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE MUM856-1 (RoW)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE S615 EEC LAN-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE S615 LAN-Router",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC622-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC632-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC636-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC642-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE SC646-2C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (JP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (ROW)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1750D (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.7.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2 EEC M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W1788-2IA M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W721-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W722-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W734-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W738-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W748-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W761-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W774-1 RJ45 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W778-1 M12 EEC (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2 SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W786-2IA RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-1 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 M12 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE W788-2 RJ45",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 (US)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WAM766-1 EEC (US)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM763-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM766-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE WUM766-1 (USA)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X200-4P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X201-3P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X201-3P IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X202-2P IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2FM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2LD TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204-2TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X204IRT PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X206-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X206-1LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X208PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X212-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X212-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X224",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X302-7 EEC (2x 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X304-2FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X306-1LD FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-2 EEC (2x 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X307-3LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2 RD (inkl. SIPLUS variants)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LD",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH+",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2LH+",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X308-2M TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X310FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X320-1 FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X320-1-2LD FE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE X408-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3 (ST, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3LD (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB205-3LD (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB208 (E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB208 (PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (ST, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3 (ST, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3LD (SC, E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB213-3LD (SC, PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB216 (E/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XB216 (PN)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2 (SC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2 (ST/BFOC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC206-2SFP G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G (EIP def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC208G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-3G PoE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-3G PoE (54 V DC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G (EIP Def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216-4C G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC216EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G (EIP Def.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XC224-4C G EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF201-3P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204 DNA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA DNA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204-2BA IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF204IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF206-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XF208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-4C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-8C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM408-8C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM416-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XM416-4C (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208 (Ethernet/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP208PoE EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216 (Ethernet/IP)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XP216POE EEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M TS (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-12M TS (24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.1.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR326-2C PoE WG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR326-2C PoE WG (without UL)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 1x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 24V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 24V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 2x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 1x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 24V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 24V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 2x230V",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR528-6M (L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE XR552-12M (2HR2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V6.5.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Security Configuration Tool (SCT)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Cloud Connect 7 CC712",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.9.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Cloud Connect 7 CC716",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.9.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1242-7 V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-7 LTE EU",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-7 LTE US",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1243-8 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1542SP-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1543-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.37",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1543SP-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1545-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.1.80",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1626",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 1628",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 343-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 443-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CP 443-1 OPC UA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Drive Controller CPU 1504D TF",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Drive Controller CPU 1507D TF",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC HMI Unified Comfort Panels family",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V18.0 Update 0 SR0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Logon V1.6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.6 Upd6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV540 H",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV540 S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV550 H",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV550 S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV560 U",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC MV560 X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V14",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V15",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V16 Update 6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC NET PC Software V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 SP1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 TeleControl",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V8.2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V9.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS 7 V9.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.1 SP2 UC04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS neo (Administration Console)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PDM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.2 SP2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Process Historian OPC UA Server",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2020 SP1 Update 1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF166C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF185C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF186C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF186CI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF188C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF188CI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF360R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF610R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF615R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF650R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF680R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC RF685R",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 Software Controller V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-PLCSIM Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC STEP 7 V5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.7 HF4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17.0.0.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.4 SP1 Update 22",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7.5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V7.5 SP2 Update 16",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOCODE ES V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.1",
                    "status": "affected",
                    "version": "V5.1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION SCOUT TIA V5.3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMOTION SCOUT TIA V5.4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS DCC V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS DCC V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V15.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAMICS Startdrive V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAUT Software ST7sc",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINAUT ST7CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC INS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0 SP2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC NMS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0 SP3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Server",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.2.28",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 1242-7 V2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 1543-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.37",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 343-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET CP 443-1 Advanced",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE X202-2P IRT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.5.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC206-2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC206-2SFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC208",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS NET SCALANCE XC216-4C",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CP 1243-1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.4.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.6.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.9.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS TIM 1531 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.4.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Safety ES V17 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V15.1 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V16 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V17 Update 5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TeleControl Server Basic V3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Portal Cloud V16",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Portal Cloud V17",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIM 1531 IRC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.4.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-14T12:12:36.346Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-108696.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-028723.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
              }
            ],
            "x_adpType": "supplier"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-22T13:27:14.476267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-835",
                    "description": "CWE-835 Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-22T13:28:08.544Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Tavis Ormandy (Google)"
            }
          ],
          "datePublic": "2022-03-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Infinite loop",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:07:01.186Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20220315.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
            },
            {
              "name": "DSA-5103",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2022/dsa-5103"
            },
            {
              "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
            },
            {
              "name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
            },
            {
              "name": "FEDORA-2022-a5f51502f0",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
            },
            {
              "name": "FEDORA-2022-9e88b5d8d7",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
            },
            {
              "name": "FEDORA-2022-8bb51f6901",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-07"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-08"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/33"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/35"
            },
            {
              "name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/May/38"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://support.apple.com/kb/HT213257"
            },
            {
              "url": "https://support.apple.com/kb/HT213256"
            },
            {
              "url": "https://support.apple.com/kb/HT213255"
            },
            {
              "url": "https://www.tenable.com/security/tns-2022-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
            },
            {
              "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
            },
            {
              "name": "GLSA-202210-02",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202210-02"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "Infinite loop in BN_mod_sqrt() reachable when parsing certificates"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2022-0778",
        "datePublished": "2022-03-15T17:05:20.382Z",
        "dateReserved": "2022-02-28T00:00:00.000Z",
        "dateUpdated": "2026-10-14T12:12:36.346Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-36516 (GCVE-0-2020-36516)

    Vulnerability from cvelistv5 – Published: 2022-02-26 03:14 – Updated: 2024-08-04 17:30
    VLAI
    Summary
    An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim's TCP session or terminate that session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T17:30:08.304Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim\u0027s TCP session or terminate that session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-31T08:06:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-36516",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in the Linux kernel through 5.16.11. The mixed IPID assignment method with the hash-based IPID assignment policy allows an off-path attacker to inject data into a victim\u0027s TCP session or terminate that session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://dl.acm.org/doi/10.1145/3372297.3417884",
                  "refsource": "MISC",
                  "url": "https://dl.acm.org/doi/10.1145/3372297.3417884"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220331-0003/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220331-0003/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-36516",
        "datePublished": "2022-02-26T03:14:46.000Z",
        "dateReserved": "2022-02-26T00:00:00.000Z",
        "dateUpdated": "2024-08-04T17:30:08.304Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3450 (GCVE-0-2021-3450)

    Vulnerability from cvelistv5 – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:03
    VLAI
    Title
    CA certificate check bypass with X509_V_FLAG_X509_STRICT
    Summary
    The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a "purpose" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named "purpose" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:02 UTC
    CWE
    • Invalid Certificate Verification
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt x_refsource_CONFIRM
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba… x_refsource_CONFIRM
    https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-listx_refsource_MLIST
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-listx_refsource_MLIST
    https://security.gentoo.org/glsa/202103-03 vendor-advisoryx_refsource_GENTOO
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://www.oracle.com/security-alerts/cpuApr2021.html x_refsource_MISC
    https://www.tenable.com/security/tns-2021-09 x_refsource_CONFIRM
    https://security.netapp.com/advisory/ntap-2021032… x_refsource_CONFIRM
    https://security.FreeBSD.org/advisories/FreeBSD-S… x_refsource_MISC
    https://www.tenable.com/security/tns-2021-05 x_refsource_CONFIRM
    https://kc.mcafee.com/corporate/index?page=conten… x_refsource_CONFIRM
    https://www.tenable.com/security/tns-2021-08 x_refsource_CONFIRM
    https://mta.openssl.org/pipermail/openssl-announc… x_refsource_MISC
    https://www.oracle.com//security-alerts/cpujul2021.html x_refsource_MISC
    https://kb.pulsesecure.net/articles/Pulse_Securit… x_refsource_CONFIRM
    https://psirt.global.sonicwall.com/vuln-detail/SN… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/cpuoct2021.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpuapr2022.html x_refsource_MISC
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/cpujul2022.html x_refsource_MISC
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.644Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_CISCO",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_GENTOO",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-08"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:02:24.642640Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:03:32.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Benjamin Kaduk (Akamai), Xiang Ding (Akamai), others at Akamai"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a \"purpose\" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named \"purpose\" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Invalid Certificate Verification",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-25T16:35:11.000Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory",
                "x_refsource_CISCO"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory",
                "x_refsource_GENTOO"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/tns-2021-08"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            }
          ],
          "title": "CA certificate check bypass with X509_V_FLAG_X509_STRICT",
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "openssl-security@openssl.org",
              "DATE_PUBLIC": "2021-03-25",
              "ID": "CVE-2021-3450",
              "STATE": "PUBLIC",
              "TITLE": "CA certificate check bypass with X509_V_FLAG_X509_STRICT"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OpenSSL",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OpenSSL"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Benjamin Kaduk (Akamai), Xiang Ding (Akamai), others at Akamai"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The X509_V_FLAG_X509_STRICT flag enables additional security checks of the certificates present in a certificate chain. It is not set by default. Starting from OpenSSL version 1.1.1h a check to disallow certificates in the chain that have explicitly encoded elliptic curve parameters was added as an additional strict check. An error in the implementation of this check meant that the result of a previous check to confirm that certificates in the chain are valid CA certificates was overwritten. This effectively bypasses the check that non-CA certificates must not be able to issue other certificates. If a \"purpose\" has been configured then there is a subsequent opportunity for checks that the certificate is a valid CA. All of the named \"purpose\" values implemented in libcrypto perform this check. Therefore, where a purpose is set the certificate chain will still be rejected even when the strict flag has been used. A purpose is set by default in libssl client and server certificate verification routines, but it can be overridden or removed by an application. In order to be affected, an application must explicitly set the X509_V_FLAG_X509_STRICT verification flag and either not set a purpose for the certificate verification or, in the case of TLS client or server applications, override the default purpose. OpenSSL versions 1.1.1h and newer are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1h-1.1.1j)."
                }
              ]
            },
            "impact": [
              {
                "lang": "eng",
                "url": "https://www.openssl.org/policies/secpolicy.html#High",
                "value": "High"
              }
            ],
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Invalid Certificate Verification"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.openssl.org/news/secadv/20210325.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.openssl.org/news/secadv/20210325.txt"
                },
                {
                  "name": "https://www.openssl.org/news/secadv/20210325.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.openssl.org/news/secadv/20210325.txt"
                },
                {
                  "name": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b",
                  "refsource": "CONFIRM",
                  "url": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2a40b7bc7b94dd7de897a74571e7024f0cf0d63b"
                },
                {
                  "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                  "refsource": "CISCO",
                  "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
                },
                {
                  "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
                },
                {
                  "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
                },
                {
                  "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
                },
                {
                  "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
                },
                {
                  "name": "GLSA-202103-03",
                  "refsource": "GENTOO",
                  "url": "https://security.gentoo.org/glsa/202103-03"
                },
                {
                  "name": "FEDORA-2021-cbf14ab8f9",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuApr2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-09",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-09"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20210326-0006/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
                },
                {
                  "name": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc",
                  "refsource": "MISC",
                  "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-05"
                },
                {
                  "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356",
                  "refsource": "CONFIRM",
                  "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
                },
                {
                  "name": "https://www.tenable.com/security/tns-2021-08",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/tns-2021-08"
                },
                {
                  "name": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html",
                  "refsource": "MISC",
                  "url": "https://mta.openssl.org/pipermail/openssl-announce/2021-March/000198.html"
                },
                {
                  "name": "https://www.oracle.com//security-alerts/cpujul2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
                },
                {
                  "name": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845",
                  "refsource": "CONFIRM",
                  "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
                },
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuoct2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3450",
        "datePublished": "2021-03-25T14:25:14.287Z",
        "dateReserved": "2021-03-19T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:03:32.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-3449 (GCVE-0-2021-3449)

    Vulnerability from cvelistv5 – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:13
    VLAI
    Title
    NULL pointer deref in signature_algorithms processing
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:05 UTC
    CWE
    • NULL pointer dereference
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 78/100 over 57 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    https://www.debian.org/security/2021/dsa-4875 vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-list
    https://security.gentoo.org/glsa/202103-03 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuApr2021.html
    https://www.tenable.com/security/tns-2021-10
    https://www.tenable.com/security/tns-2021-09
    https://security.netapp.com/advisory/ntap-2021051…
    https://security.netapp.com/advisory/ntap-2021032…
    https://security.FreeBSD.org/advisories/FreeBSD-S…
    https://www.tenable.com/security/tns-2021-06
    https://www.tenable.com/security/tns-2021-05
    https://kc.mcafee.com/corporate/index?page=conten…
    https://www.oracle.com//security-alerts/cpujul2021.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://kb.pulsesecure.net/articles/Pulse_Securit…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://www.oracle.com/security-alerts/cpuoct2021.html
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://security.netapp.com/advisory/ntap-2024062…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.609Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "DSA-4875",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-4875"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-10"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:05:43.522199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:13:50.095Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL pointer dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:05:57.096Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "DSA-4875",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-4875"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-10"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
            },
            {
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "NULL pointer deref in signature_algorithms processing"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3449",
        "datePublished": "2021-03-25T14:25:13.659Z",
        "dateReserved": "2021-03-17T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:13:50.095Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-16166 (GCVE-0-2020-16166)

    Vulnerability from cvelistv5 – Published: 2020-07-30 20:05 – Updated: 2024-08-04 13:37
    VLAI
    Summary
    The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T13:37:53.889Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
              },
              {
                "name": "openSUSE-SU-2020:1153",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
              },
              {
                "name": "FEDORA-2020-8d634e31c0",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
              },
              {
                "name": "FEDORA-2020-2cd6393548",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
              },
              {
                "name": "openSUSE-SU-2020:1236",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
              },
              {
                "name": "USN-4526-1",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_UBUNTU",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4526-1/"
              },
              {
                "name": "USN-4525-1",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_UBUNTU",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4525-1/"
              },
              {
                "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
              },
              {
                "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
              },
              {
                "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2012.07432.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-14T17:20:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
            },
            {
              "name": "openSUSE-SU-2020:1153",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
            },
            {
              "name": "FEDORA-2020-8d634e31c0",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
            },
            {
              "name": "FEDORA-2020-2cd6393548",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
            },
            {
              "name": "openSUSE-SU-2020:1236",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
            },
            {
              "name": "USN-4526-1",
              "tags": [
                "vendor-advisory",
                "x_refsource_UBUNTU"
              ],
              "url": "https://usn.ubuntu.com/4526-1/"
            },
            {
              "name": "USN-4525-1",
              "tags": [
                "vendor-advisory",
                "x_refsource_UBUNTU"
              ],
              "url": "https://usn.ubuntu.com/4525-1/"
            },
            {
              "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
            },
            {
              "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
            },
            {
              "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://arxiv.org/pdf/2012.07432.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-16166",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Linux kernel through 5.7.11 allows remote attackers to make observations that help to obtain sensitive information about the internal state of the network RNG, aka CID-f227e3ec3b5c. This is related to drivers/char/random.c and kernel/time/timer.c."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4",
                  "refsource": "MISC",
                  "url": "https://github.com/torvalds/linux/commit/f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
                },
                {
                  "name": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4",
                  "refsource": "MISC",
                  "url": "https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/commit/?id=f227e3ec3b5cad859ad15666874405e8c1bbc1d4"
                },
                {
                  "name": "openSUSE-SU-2020:1153",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00009.html"
                },
                {
                  "name": "FEDORA-2020-8d634e31c0",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/MFBCLQWJI5I4G25TVJNLXLAXJ4MERQNW/"
                },
                {
                  "name": "FEDORA-2020-2cd6393548",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/AAPTLPAEKVAJYJ4LHN7VH4CN2W75R2YW/"
                },
                {
                  "name": "openSUSE-SU-2020:1236",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00047.html"
                },
                {
                  "name": "USN-4526-1",
                  "refsource": "UBUNTU",
                  "url": "https://usn.ubuntu.com/4526-1/"
                },
                {
                  "name": "USN-4525-1",
                  "refsource": "UBUNTU",
                  "url": "https://usn.ubuntu.com/4525-1/"
                },
                {
                  "name": "[debian-lts-announce] 20200928 [SECURITY] [DLA 2385-1] linux-4.19 security update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00025.html"
                },
                {
                  "name": "[debian-lts-announce] 20201030 [SECURITY] [DLA 2420-1] linux security update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00032.html"
                },
                {
                  "name": "[debian-lts-announce] 20201031 [SECURITY] [DLA 2420-2] linux regression update",
                  "refsource": "MLIST",
                  "url": "https://lists.debian.org/debian-lts-announce/2020/10/msg00034.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuApr2021.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20200814-0004/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20200814-0004/"
                },
                {
                  "name": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638",
                  "refsource": "MISC",
                  "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=c51f8f88d705e06bd696d7510aff22b33eb8e638"
                },
                {
                  "name": "https://arxiv.org/pdf/2012.07432.pdf",
                  "refsource": "MISC",
                  "url": "https://arxiv.org/pdf/2012.07432.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-16166",
        "datePublished": "2020-07-30T20:05:24.000Z",
        "dateReserved": "2020-07-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T13:37:53.889Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-20907 (GCVE-0-2019-20907)

    Vulnerability from cvelistv5 – Published: 2020-07-13 00:00 – Updated: 2026-10-14 07:57
    VLAI
    Summary
    In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-07 17:58 UTC
    CWE
    • n/a
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    URL Tags
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://usn.ubuntu.com/4428-1/ vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://security.gentoo.org/glsa/202008-01 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.debian.org/debian-lts-announce/2020… mailing-list
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    http://lists.opensuse.org/opensuse-security-annou… vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://lists.debian.org/debian-lts-announce/2020… mailing-list
    https://www.oracle.com/security-alerts/cpujan2021.html
    https://bugs.python.org/issue39017
    https://github.com/python/cpython/pull/21454
    https://security.netapp.com/advisory/ntap-2020073…
    https://lists.debian.org/debian-lts-announce/2023… mailing-list
    https://cert-portal.siemens.com/productcert/html/…
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:53:09.456Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "FEDORA-2020-dfb11916cc",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
              },
              {
                "name": "FEDORA-2020-e9251de272",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
              },
              {
                "name": "USN-4428-1",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://usn.ubuntu.com/4428-1/"
              },
              {
                "name": "FEDORA-2020-c3b07cc5c9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
              },
              {
                "name": "FEDORA-2020-aab24d3714",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
              },
              {
                "name": "FEDORA-2020-bb919e575e",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
              },
              {
                "name": "FEDORA-2020-97d775e649",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
              },
              {
                "name": "GLSA-202008-01",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202008-01"
              },
              {
                "name": "FEDORA-2020-826b24c329",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
              },
              {
                "name": "FEDORA-2020-1ddd5273d6",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
              },
              {
                "name": "FEDORA-2020-87c0a0a52d",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
              },
              {
                "name": "FEDORA-2020-efb908b6a8",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
              },
              {
                "name": "FEDORA-2020-d808fdd597",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
              },
              {
                "name": "FEDORA-2020-982b2950db",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
              },
              {
                "name": "FEDORA-2020-c539babb0a",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
              },
              {
                "name": "[debian-lts-announce] 20200822 [SECURITY] [DLA 2337-1] python2.7 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
              },
              {
                "name": "openSUSE-SU-2020:1254",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
              },
              {
                "name": "openSUSE-SU-2020:1257",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
              },
              {
                "name": "openSUSE-SU-2020:1258",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
              },
              {
                "name": "openSUSE-SU-2020:1265",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
              },
              {
                "name": "FEDORA-2020-d30881c970",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
              },
              {
                "name": "[debian-lts-announce] 20201119 [SECURITY] [DLA 2456-1] python3.5 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://bugs.python.org/issue39017"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/python/cpython/pull/21454"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
              },
              {
                "name": "[debian-lts-announce] 20230524 [SECURITY] [DLA 3432-1] python2.7 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 5.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-20907",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-07T17:58:36.334729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-835",
                    "description": "CWE-835 Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-07T17:59:38.830Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.1.5",
                    "status": "affected",
                    "version": "V3.1.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-14T07:57:15.074Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-24T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "FEDORA-2020-dfb11916cc",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VT4AF72TJ2XNIKCR4WEBR7URBJJ4YZRD/"
            },
            {
              "name": "FEDORA-2020-e9251de272",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CAXHCY4V3LPAAJOBCJ26ISZ4NUXQXTUZ/"
            },
            {
              "name": "USN-4428-1",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://usn.ubuntu.com/4428-1/"
            },
            {
              "name": "FEDORA-2020-c3b07cc5c9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V3TALOUBYU2MQD4BPLRTDQUMBKGCAXUA/"
            },
            {
              "name": "FEDORA-2020-aab24d3714",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YSL3XWVDMSMKO23HR74AJQ6VEM3C2NTS/"
            },
            {
              "name": "FEDORA-2020-bb919e575e",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LE4O3PNDNNOMSKHNUKZKD3NGHIFUFDPX/"
            },
            {
              "name": "FEDORA-2020-97d775e649",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/TOGKLGTXZLHQQFBVCAPSUDA6DOOJFNRY/"
            },
            {
              "name": "GLSA-202008-01",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202008-01"
            },
            {
              "name": "FEDORA-2020-826b24c329",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/PDKKRXLNVXRF6VGERZSR3OMQR5D5QI6I/"
            },
            {
              "name": "FEDORA-2020-1ddd5273d6",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YILCHHTNLH4GG4GSQBX2MZRKZBXOLCKE/"
            },
            {
              "name": "FEDORA-2020-87c0a0a52d",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NTBKKOLFFNHG6CM4ACDX4APHSD5ZX5N4/"
            },
            {
              "name": "FEDORA-2020-efb908b6a8",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CNHPQGSP2YM3JAUD2VAMPXTIUQTZ2M2U/"
            },
            {
              "name": "FEDORA-2020-d808fdd597",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/V53P2YOLEQH4J7S5QHXMKMZYFTVVMTMO/"
            },
            {
              "name": "FEDORA-2020-982b2950db",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CTUNTBJ3POHONQOTLEZC46POCIYYTAKZ/"
            },
            {
              "name": "FEDORA-2020-c539babb0a",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/36XI3EEQNMHGOZEI63Y7UV6XZRELYEAU/"
            },
            {
              "name": "[debian-lts-announce] 20200822 [SECURITY] [DLA 2337-1] python2.7 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/08/msg00034.html"
            },
            {
              "name": "openSUSE-SU-2020:1254",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00051.html"
            },
            {
              "name": "openSUSE-SU-2020:1257",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00052.html"
            },
            {
              "name": "openSUSE-SU-2020:1258",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00053.html"
            },
            {
              "name": "openSUSE-SU-2020:1265",
              "tags": [
                "vendor-advisory"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-08/msg00056.html"
            },
            {
              "name": "FEDORA-2020-d30881c970",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OXI72HIHMXCQFWTULUXDG7VDA2BCYL4Y/"
            },
            {
              "name": "[debian-lts-announce] 20201119 [SECURITY] [DLA 2456-1] python3.5 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2020/11/msg00032.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
            },
            {
              "url": "https://bugs.python.org/issue39017"
            },
            {
              "url": "https://github.com/python/cpython/pull/21454"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20200731-0002/"
            },
            {
              "name": "[debian-lts-announce] 20230524 [SECURITY] [DLA 3432-1] python2.7 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2023/05/msg00024.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20907",
        "datePublished": "2020-07-13T00:00:00.000Z",
        "dateReserved": "2020-07-13T00:00:00.000Z",
        "dateUpdated": "2026-10-14T07:57:15.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",