Search criteria Use full-text search for keyword queries.
Combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by dates instead of relevance.

8 vulnerabilities found for clininet by cgm

CVE-2025-58406 (GCVE-0-2025-58406)

Vulnerability from nvd – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:21
VLAI?
Title
Lack of HTTP Response Headers
Summary
The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross‑origin isolation, and missing transport security controls.
CWE
  • CWE-693 - Protection Mechanism Failure
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58406",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:21:06.221923Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:21:46.406Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe CGM CLININET application respond without essential security HTTP headers, exposing users to client\u2011side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross\u2011origin isolation, and missing transport security controls.\u003c/span\u003e"
            }
          ],
          "value": "The CGM CLININET application respond without essential security HTTP headers, exposing users to client\u2011side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross\u2011origin isolation, and missing transport security controls."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693 Protection Mechanism Failure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:56.975Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Lack of HTTP Response Headers",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58406",
    "datePublished": "2026-03-02T11:16:56.975Z",
    "dateReserved": "2025-09-01T07:18:45.944Z",
    "dateUpdated": "2026-03-02T12:21:46.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58405 (GCVE-0-2025-58405)

Vulnerability from nvd – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:27
VLAI?
Title
Lack of protection mechanisms against Clickjacking attacks
Summary
The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses.
CWE
  • CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:24:46.564303Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:27:59.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame\u2011busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
            }
          ],
          "value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame\u2011busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1021",
              "description": "CWE-1021 Improper Restriction of Rendered UI Layers or Frames",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:45.223Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Lack of protection mechanisms against Clickjacking attacks",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58405",
    "datePublished": "2026-03-02T11:16:45.223Z",
    "dateReserved": "2025-09-01T07:18:45.944Z",
    "dateUpdated": "2026-03-02T12:27:59.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58402 (GCVE-0-2025-58402)

Vulnerability from nvd – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:39
VLAI?
Title
Insecure Direct Object Reference Message ID
Summary
The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS4 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58402",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:35:35.178582Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:39:17.339Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET application uses direct, sequential object identifiers \"MessageID\" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users."
            }
          ],
          "value": "The CGM CLININET application uses direct, sequential object identifiers \"MessageID\" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:31.420Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure Direct Object Reference Message ID",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58402",
    "datePublished": "2026-03-02T11:16:31.420Z",
    "dateReserved": "2025-09-01T07:18:45.943Z",
    "dateUpdated": "2026-03-02T12:39:17.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-30042 (GCVE-0-2025-30042)

Vulnerability from nvd – Published: 2026-03-02 11:14 – Updated: 2026-03-02 13:21
VLAI?
Title
Session generation possible with certificate number only
Summary
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.
CWE
  • CWE-603 - Use of Client-Side Authentication
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS2 (custom)
Create a notification for this product.
Credits
Maciej Kazulak
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30042",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T13:20:54.724155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T13:21:10.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Maciej Kazulak"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key."
            }
          ],
          "value": "The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 9,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-603",
              "description": "CWE-603 Use of Client-Side Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:14:46.946Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Session generation possible with certificate number only",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-30042",
    "datePublished": "2026-03-02T11:14:46.946Z",
    "dateReserved": "2025-03-14T14:54:23.999Z",
    "dateUpdated": "2026-03-02T13:21:10.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58406 (GCVE-0-2025-58406)

Vulnerability from cvelistv5 – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:21
VLAI?
Title
Lack of HTTP Response Headers
Summary
The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross‑origin isolation, and missing transport security controls.
CWE
  • CWE-693 - Protection Mechanism Failure
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58406",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:21:06.221923Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:21:46.406Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe CGM CLININET application respond without essential security HTTP headers, exposing users to client\u2011side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross\u2011origin isolation, and missing transport security controls.\u003c/span\u003e"
            }
          ],
          "value": "The CGM CLININET application respond without essential security HTTP headers, exposing users to client\u2011side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross\u2011origin isolation, and missing transport security controls."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693 Protection Mechanism Failure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:56.975Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Lack of HTTP Response Headers",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58406",
    "datePublished": "2026-03-02T11:16:56.975Z",
    "dateReserved": "2025-09-01T07:18:45.944Z",
    "dateUpdated": "2026-03-02T12:21:46.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58405 (GCVE-0-2025-58405)

Vulnerability from cvelistv5 – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:27
VLAI?
Title
Lack of protection mechanisms against Clickjacking attacks
Summary
The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses.
CWE
  • CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:24:46.564303Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:27:59.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame\u2011busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
            }
          ],
          "value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame\u2011busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1021",
              "description": "CWE-1021 Improper Restriction of Rendered UI Layers or Frames",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:45.223Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Lack of protection mechanisms against Clickjacking attacks",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58405",
    "datePublished": "2026-03-02T11:16:45.223Z",
    "dateReserved": "2025-09-01T07:18:45.944Z",
    "dateUpdated": "2026-03-02T12:27:59.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58402 (GCVE-0-2025-58402)

Vulnerability from cvelistv5 – Published: 2026-03-02 11:16 – Updated: 2026-03-02 12:39
VLAI?
Title
Insecure Direct Object Reference Message ID
Summary
The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS4 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58402",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T12:35:35.178582Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T12:39:17.339Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET application uses direct, sequential object identifiers \"MessageID\" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users."
            }
          ],
          "value": "The CGM CLININET application uses direct, sequential object identifiers \"MessageID\" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:16:31.420Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure Direct Object Reference Message ID",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-58402",
    "datePublished": "2026-03-02T11:16:31.420Z",
    "dateReserved": "2025-09-01T07:18:45.943Z",
    "dateUpdated": "2026-03-02T12:39:17.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-30042 (GCVE-0-2025-30042)

Vulnerability from cvelistv5 – Published: 2026-03-02 11:14 – Updated: 2026-03-02 13:21
VLAI?
Title
Session generation possible with certificate number only
Summary
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.
CWE
  • CWE-603 - Use of Client-Side Authentication
Assigner
Impacted products
Vendor Product Version
CGM CGM CLININET Affected: 0 , < 2025.MS2 (custom)
Create a notification for this product.
Credits
Maciej Kazulak
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30042",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-02T13:20:54.724155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-02T13:21:10.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CGM CLININET",
          "vendor": "CGM",
          "versions": [
            {
              "lessThan": "2025.MS2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Maciej Kazulak"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key."
            }
          ],
          "value": "The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 9,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-603",
              "description": "CWE-603 Use of Client-Side Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-02T11:14:46.946Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Session generation possible with certificate number only",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-30042",
    "datePublished": "2026-03-02T11:14:46.946Z",
    "dateReserved": "2025-03-14T14:54:23.999Z",
    "dateUpdated": "2026-03-02T13:21:10.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}