Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for centro_grande_firmware by swisscom

    CVE-2019-19942 (GCVE-0-2019-19942)

    Vulnerability from nvd – Published: 2020-03-16 15:24 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.044Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:00:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19942",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19942",
        "datePublished": "2020-03-16T15:24:46.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19941 (GCVE-0-2019-19941)

    Vulnerability from nvd – Published: 2020-03-16 15:19 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.104Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:01:39.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19941",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19941",
        "datePublished": "2020-03-16T15:19:52.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.104Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19940 (GCVE-0-2019-19940)

    Vulnerability from nvd – Published: 2020-03-16 15:10 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.067Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:00:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19940",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19940",
        "datePublished": "2020-03-16T15:10:31.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-1188 (GCVE-0-2015-1188)

    Vulnerability from nvd – Published: 2015-05-20 18:00 – Updated: 2024-08-06 04:33
    VLAI
    Summary
    The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2015/Apr/103 mailing-listx_refsource_FULLDISC
    Date Public
    2015-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:33:20.687Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-05-20T18:57:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2015-1188",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2015-1188",
        "datePublished": "2015-05-20T18:00:00.000Z",
        "dateReserved": "2015-01-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:33:20.687Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19942 (GCVE-0-2019-19942)

    Vulnerability from cvelistv5 – Published: 2020-03-16 15:24 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.044Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:00:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19942",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing output sanitation in Swisscom Centro Grande Centro Grande before 6.16.12, Centro Business 1.0 (ADB) before 7.10.18, and Centro Business 2.0 before 8.02.04 allows a remote attacker to perform DNS spoofing against the web interface via crafted hostnames in DHCP requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19942",
        "datePublished": "2020-03-16T15:24:46.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19941 (GCVE-0-2019-19941)

    Vulnerability from cvelistv5 – Published: 2020-03-16 15:19 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.104Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:01:39.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19941",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing hostname validation in Swisscom Centro Grande before 6.16.12 allows a remote attacker to inject its local IP address as a domain entry in the DNS service of the router via crafted hostnames in DHCP requests, causing XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19941",
        "datePublished": "2020-03-16T15:19:52.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.104Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19940 (GCVE-0-2019-19940)

    Vulnerability from cvelistv5 – Published: 2020-03-16 15:10 – Updated: 2024-08-05 02:32
    VLAI
    Summary
    Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:32:10.067Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-01-13T16:00:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19940",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt",
                  "refsource": "CONFIRM",
                  "url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2019-19940ff.txt"
                },
                {
                  "name": "https://www.swisscom.ch/en/residential/help/device/internet-router.html",
                  "refsource": "MISC",
                  "url": "https://www.swisscom.ch/en/residential/help/device/internet-router.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19940",
        "datePublished": "2020-03-16T15:10:31.000Z",
        "dateReserved": "2019-12-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:32:10.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-1188 (GCVE-0-2015-1188)

    Vulnerability from cvelistv5 – Published: 2015-05-20 18:00 – Updated: 2024-08-06 04:33
    VLAI
    Summary
    The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2015/Apr/103 mailing-listx_refsource_FULLDISC
    Date Public
    2015-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:33:20.687Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-05-20T18:57:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2015-1188",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The certificate verification functions in the HNDS service in Swisscom Centro Grande (ADB) DSL routers with firmware before 6.14.00 allows remote attackers to access the management functions via unknown vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20150429 CVE-ID 2015-1188: Swisscom DSL Router Centro Grande (ADB)",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2015/Apr/103"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2015-1188",
        "datePublished": "2015-05-20T18:00:00.000Z",
        "dateReserved": "2015-01-17T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:33:20.687Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }