Search criteria

110 vulnerabilities found for centreon_web by centreon

CVE-2025-12513 (GCVE-0-2025-12513)

Vulnerability from nvd – Published: 2026-01-05 13:43 – Updated: 2026-01-08 15:40
VLAI?
Title
A user with elevated privileges can inject XSS in the Hosts configuration parameters page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T21:18:55.475622Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T21:19:04.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hosts configuration form"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges.\n\nThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:40:41.095Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-12513-centreon-web-medium-severity-5360"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hosts configuration parameters page",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-12513",
    "datePublished": "2026-01-05T13:43:42.969Z",
    "dateReserved": "2025-10-30T15:18:36.025Z",
    "dateUpdated": "2026-01-08T15:40:41.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13056 (GCVE-0-2025-13056)

Vulnerability from nvd – Published: 2026-01-05 10:10 – Updated: 2026-01-08 15:41
VLAI?
Title
A user with elevated privileges can inject XSS in the Administration ACL Menus configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
marceloQJ
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13056",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:29:55.941198Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:30:26.123Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Administration ACL menu configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "marceloQJ"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) \n\nallows Stored XSS to users with high privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) \n\nallows Stored XSS to users with high privileges.\n\nThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:41:37.647Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-13056-centreon-web-medium-severity-5358"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Administration ACL Menus configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-13056",
    "datePublished": "2026-01-05T10:10:35.646Z",
    "dateReserved": "2025-11-12T11:06:17.582Z",
    "dateUpdated": "2026-01-08T15:41:37.647Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12519 (GCVE-0-2025-12519)

Vulnerability from nvd – Published: 2026-01-05 10:15 – Updated: 2026-01-08 15:41
VLAI?
Title
Information disclosure on Administration parameters API endpoint
Summary
Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
Marcelo Quieroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12519",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:28:11.833421Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:28:27.978Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Administration parameters API endpoint"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Quieroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations.\u0026nbsp;\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations.\u00a0This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862 Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:41:12.866Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-12519-centreon-web-medium-severity-5359"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information disclosure on Administration parameters API endpoint",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-12519",
    "datePublished": "2026-01-05T10:15:08.921Z",
    "dateReserved": "2025-10-30T15:49:52.593Z",
    "dateUpdated": "2026-01-08T15:41:12.866Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-5965 (GCVE-0-2025-5965)

Vulnerability from nvd – Published: 2026-01-05 10:06 – Updated: 2026-01-08 15:43
VLAI?
Title
RCE via the backup feature available only to user with high privilege
Summary
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (semver)
Affected: 24.10.0 , < 24.10.15 (semver)
Affected: 24.04.0 , < 24.04.19 (semver)
Create a notification for this product.
Credits
h00die-gr3y
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5965",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:01:00.415596Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:01:20.692Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Backup configuration in the administration setup"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "h00die-gr3y"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:43:03.373Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via the backup feature available only to user with high privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-5965",
    "datePublished": "2026-01-05T10:06:05.494Z",
    "dateReserved": "2025-06-10T08:14:47.529Z",
    "dateUpdated": "2026-01-08T15:43:03.373Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-54890 (GCVE-0-2025-54890)

Vulnerability from nvd – Published: 2025-12-22 11:07 – Updated: 2026-01-05 09:51
VLAI?
Title
A user with elevated privileges can inject XSS in the Hostgroups configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Affected: 23.10.0 , < 23.10.29 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54890",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T13:00:05.415109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T13:00:14.622Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hostgroup configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.29",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored \n\nXSS by users with elevated privileges.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored \n\nXSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-05T09:51:16.625Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54890-centreon-web-medium-severity-5342"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hostgroups configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54890",
    "datePublished": "2025-12-22T11:07:28.095Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2026-01-05T09:51:16.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-10023 (GCVE-0-2025-10023)

Vulnerability from nvd – Published: 2025-10-27 15:07 – Updated: 2025-10-30 13:48
VLAI?
Title
A user with elevated privileges can inject XSS in the Services Meta-services configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Services Meta-services modules) allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.9 (custom)
Affected: 24.04.0 , < 24.04.16 (custom)
Affected: 23.10.0 , < 23.10.26 (custom)
Create a notification for this product.
Credits
SpawnZii
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10023",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-27T15:24:00.829299Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-27T15:24:51.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Services Meta-services"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.9",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.16",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.26",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "24.10.9",
                  "versionStartIncluding": "24.10.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "24.04.16",
                  "versionStartIncluding": "24.04.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "23.10.26",
                  "versionStartIncluding": "23.10.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SpawnZii"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Services Meta-services modules) \n\n\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eallows Stored XSS by users with elevated privileges\u003c/span\u003e.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Services Meta-services modules) \n\nallows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T13:48:16.904Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-10023-centreon-web-all-versions-medium-severity-5179"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Services Meta-services configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-10023",
    "datePublished": "2025-10-27T15:07:21.621Z",
    "dateReserved": "2025-09-05T11:48:20.164Z",
    "dateUpdated": "2025-10-30T13:48:16.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-8459 (GCVE-0-2025-8459)

Vulnerability from nvd – Published: 2025-10-14 17:11 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with low privileges can inject XSS in the Monitoring Recurrent downtimes page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8459",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T17:52:11.705185Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T17:52:20.595Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Monitoring recurrent downtime scheduler"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:21.944Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8459-centreon-web-all-versions-high-severity-5117"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with low privileges can inject XSS in the Monitoring Recurrent downtimes page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8459",
    "datePublished": "2025-10-14T17:11:30.565Z",
    "dateReserved": "2025-08-01T13:53:19.714Z",
    "dateUpdated": "2025-10-15T13:13:21.944Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8430 (GCVE-0-2025-8430)

Vulnerability from nvd – Published: 2025-10-14 16:54 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with elevated privileges can inject XSS in the Commands Connectors configuration configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8430",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T19:18:36.311886Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T19:18:43.961Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Commands Connectors configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:42.544Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8430-centreon-web-all-versions-medium-severity-5118"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Commands Connectors configuration configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8430",
    "datePublished": "2025-10-14T16:54:43.948Z",
    "dateReserved": "2025-07-31T18:25:10.514Z",
    "dateUpdated": "2025-10-15T13:13:42.544Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8429 (GCVE-0-2025-8429)

Vulnerability from nvd – Published: 2025-10-14 15:29 – Updated: 2025-10-15 13:14
VLAI?
Title
A user with elevated privileges can inject XSS in the ACL Action access configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8429",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:08:27.369444Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:08:35.098Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "ACL Action access configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:14:03.171Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8429-centreon-web-all-versions-medium-severity-5119"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the ACL Action access configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8429",
    "datePublished": "2025-10-14T15:29:56.095Z",
    "dateReserved": "2025-07-31T18:24:05.148Z",
    "dateUpdated": "2025-10-15T13:14:03.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54893 (GCVE-0-2025-54893)

Vulnerability from nvd – Published: 2025-10-14 15:24 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with elevated privileges can inject XSS in the Hosts templates configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:07:58.282510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:08:06.222Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hosts templates configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:00.967Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54893-centreon-web-all-versions-medium-severity-5120"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hosts templates configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54893",
    "datePublished": "2025-10-14T15:24:24.017Z",
    "dateReserved": "2025-07-31T18:22:28.421Z",
    "dateUpdated": "2025-10-15T13:13:00.967Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8428 (GCVE-0-2025-8428)

Vulnerability from nvd – Published: 2025-10-14 14:22 – Updated: 2025-10-14 16:01
VLAI?
Title
XSS found in the HTTP loader widget
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
SpawnZii
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8428",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:01:45.943850Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:01:54.470Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "HTTP Loader widget"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SpawnZii"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T14:22:03.098Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8428-centreon-web-all-versions-medium-severity-5103"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "XSS found in the HTTP loader widget",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8428",
    "datePublished": "2025-10-14T14:22:03.098Z",
    "dateReserved": "2025-07-31T18:23:59.321Z",
    "dateUpdated": "2025-10-14T16:01:54.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5946 (GCVE-0-2025-5946)

Vulnerability from nvd – Published: 2025-10-14 14:29 – Updated: 2025-10-14 16:03
VLAI?
Title
RCE via the poller reload feature available only to user with high privilege
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
h00die-gr3y a.k.a. Hanko van Giessen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5946",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:03:02.831678Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:03:12.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Poller reload setup in the configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "h00die-gr3y a.k.a. Hanko van Giessen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInfra Monitoring \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e(Poller reload setup in the configuration modules) allows OS Command Injection.\u003c/span\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\u003c/span\u003e\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T14:29:00.514Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-versions-high-severity-5104"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via the poller reload feature available only to user with high privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-5946",
    "datePublished": "2025-10-14T14:29:00.514Z",
    "dateReserved": "2025-06-09T17:09:29.545Z",
    "dateUpdated": "2025-10-14T16:03:12.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54892 (GCVE-0-2025-54892)

Vulnerability from nvd – Published: 2025-10-14 14:59 – Updated: 2025-10-15 13:12
VLAI?
Title
A user with elevated privileges can inject XSS in the SNMP traps group configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:05:09.568499Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:05:17.713Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "SNMP traps group configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:12:33.859Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54892-centreon-web-all-versions-medium-severity-5121"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the SNMP traps group configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54892",
    "datePublished": "2025-10-14T14:59:10.681Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2025-10-15T13:12:33.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54891 (GCVE-0-2025-54891)

Vulnerability from nvd – Published: 2025-10-14 15:07 – Updated: 2025-10-15 13:12
VLAI?
Title
A user with elevated privileges can inject XSS in the ACL Resource Access configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:06:28.726983Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:06:36.058Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "ACL Resource access configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:12:10.485Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54891-centreon-web-all-versions-medium-severity-5122"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the ACL Resource Access configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54891",
    "datePublished": "2025-10-14T15:07:01.145Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2025-10-15T13:12:10.485Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54889 (GCVE-0-2025-54889)

Vulnerability from nvd – Published: 2025-10-14 14:54 – Updated: 2025-10-15 13:11
VLAI?
Title
A user with elevated privileges can inject XSS in the SNMP traps manufacturer configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54889",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:04:42.477460Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:04:50.878Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "SNMP traps manufacturer configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:11:44.087Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54889-centreon-web-all-versions-medium-severity-5123"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the SNMP traps manufacturer configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54889",
    "datePublished": "2025-10-14T14:54:31.311Z",
    "dateReserved": "2025-07-31T18:22:28.419Z",
    "dateUpdated": "2025-10-15T13:11:44.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-12513 (GCVE-0-2025-12513)

Vulnerability from cvelistv5 – Published: 2026-01-05 13:43 – Updated: 2026-01-08 15:40
VLAI?
Title
A user with elevated privileges can inject XSS in the Hosts configuration parameters page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T21:18:55.475622Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T21:19:04.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hosts configuration form"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges.\n\nThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:40:41.095Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-12513-centreon-web-medium-severity-5360"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hosts configuration parameters page",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-12513",
    "datePublished": "2026-01-05T13:43:42.969Z",
    "dateReserved": "2025-10-30T15:18:36.025Z",
    "dateUpdated": "2026-01-08T15:40:41.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12519 (GCVE-0-2025-12519)

Vulnerability from cvelistv5 – Published: 2026-01-05 10:15 – Updated: 2026-01-08 15:41
VLAI?
Title
Information disclosure on Administration parameters API endpoint
Summary
Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
Marcelo Quieroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12519",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:28:11.833421Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:28:27.978Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Administration parameters API endpoint"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Quieroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations.\u0026nbsp;\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations.\u00a0This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862 Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:41:12.866Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-12519-centreon-web-medium-severity-5359"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information disclosure on Administration parameters API endpoint",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-12519",
    "datePublished": "2026-01-05T10:15:08.921Z",
    "dateReserved": "2025-10-30T15:49:52.593Z",
    "dateUpdated": "2026-01-08T15:41:12.866Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13056 (GCVE-0-2025-13056)

Vulnerability from cvelistv5 – Published: 2026-01-05 10:10 – Updated: 2026-01-08 15:41
VLAI?
Title
A user with elevated privileges can inject XSS in the Administration ACL Menus configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (custom)
Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Create a notification for this product.
Credits
marceloQJ
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13056",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:29:55.941198Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:30:26.123Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Administration ACL menu configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "marceloQJ"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) \n\nallows Stored XSS to users with high privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Administration ACL menu configuration modules) \n\nallows Stored XSS to users with high privileges.\n\nThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:41:37.647Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-13056-centreon-web-medium-severity-5358"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Administration ACL Menus configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-13056",
    "datePublished": "2026-01-05T10:10:35.646Z",
    "dateReserved": "2025-11-12T11:06:17.582Z",
    "dateUpdated": "2026-01-08T15:41:37.647Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-5965 (GCVE-0-2025-5965)

Vulnerability from cvelistv5 – Published: 2026-01-05 10:06 – Updated: 2026-01-08 15:43
VLAI?
Title
RCE via the backup feature available only to user with high privilege
Summary
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 25.10.0 , < 25.10.2 (semver)
Affected: 24.10.0 , < 24.10.15 (semver)
Affected: 24.04.0 , < 24.04.19 (semver)
Create a notification for this product.
Credits
h00die-gr3y
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5965",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-05T20:01:00.415596Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-05T20:01:20.692Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Backup configuration in the administration setup"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "25.10.2",
              "status": "affected",
              "version": "25.10.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "h00die-gr3y"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
            }
          ],
          "value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-08T15:43:03.373Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via the backup feature available only to user with high privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-5965",
    "datePublished": "2026-01-05T10:06:05.494Z",
    "dateReserved": "2025-06-10T08:14:47.529Z",
    "dateUpdated": "2026-01-08T15:43:03.373Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-54890 (GCVE-0-2025-54890)

Vulnerability from cvelistv5 – Published: 2025-12-22 11:07 – Updated: 2026-01-05 09:51
VLAI?
Title
A user with elevated privileges can inject XSS in the Hostgroups configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.15 (custom)
Affected: 24.04.0 , < 24.04.19 (custom)
Affected: 23.10.0 , < 23.10.29 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54890",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T13:00:05.415109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T13:00:14.622Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hostgroup configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.15",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.19",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.29",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored \n\nXSS by users with elevated privileges.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hostgroup configuration page) allows Stored \n\nXSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19, from 23.10.0 before 23.10.29."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-05T09:51:16.625Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54890-centreon-web-medium-severity-5342"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hostgroups configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54890",
    "datePublished": "2025-12-22T11:07:28.095Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2026-01-05T09:51:16.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-10023 (GCVE-0-2025-10023)

Vulnerability from cvelistv5 – Published: 2025-10-27 15:07 – Updated: 2025-10-30 13:48
VLAI?
Title
A user with elevated privileges can inject XSS in the Services Meta-services configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Services Meta-services modules) allows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.9 (custom)
Affected: 24.04.0 , < 24.04.16 (custom)
Affected: 23.10.0 , < 23.10.26 (custom)
Create a notification for this product.
Credits
SpawnZii
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10023",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-27T15:24:00.829299Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-27T15:24:51.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Services Meta-services"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.9",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.16",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.26",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "24.10.9",
                  "versionStartIncluding": "24.10.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "24.04.16",
                  "versionStartIncluding": "24.04.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:centreon:infra_monitoring:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "23.10.26",
                  "versionStartIncluding": "23.10.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SpawnZii"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Services Meta-services modules) \n\n\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eallows Stored XSS by users with elevated privileges\u003c/span\u003e.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Services Meta-services modules) \n\nallows Stored XSS by users with elevated privileges.This issue affects Infra Monitoring: from 24.10.0 before 24.10.9, from 24.04.0 before 24.04.16, from 23.10.0 before 23.10.26."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T13:48:16.904Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-10023-centreon-web-all-versions-medium-severity-5179"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Services Meta-services configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-10023",
    "datePublished": "2025-10-27T15:07:21.621Z",
    "dateReserved": "2025-09-05T11:48:20.164Z",
    "dateUpdated": "2025-10-30T13:48:16.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-8459 (GCVE-0-2025-8459)

Vulnerability from cvelistv5 – Published: 2025-10-14 17:11 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with low privileges can inject XSS in the Monitoring Recurrent downtimes page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8459",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T17:52:11.705185Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T17:52:20.595Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Monitoring recurrent downtime scheduler"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Monitoring recurrent downtime scheduler modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:21.944Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8459-centreon-web-all-versions-high-severity-5117"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with low privileges can inject XSS in the Monitoring Recurrent downtimes page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8459",
    "datePublished": "2025-10-14T17:11:30.565Z",
    "dateReserved": "2025-08-01T13:53:19.714Z",
    "dateUpdated": "2025-10-15T13:13:21.944Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8430 (GCVE-0-2025-8430)

Vulnerability from cvelistv5 – Published: 2025-10-14 16:54 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with elevated privileges can inject XSS in the Commands Connectors configuration configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8430",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T19:18:36.311886Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T19:18:43.961Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Commands Connectors configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:42.544Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8430-centreon-web-all-versions-medium-severity-5118"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Commands Connectors configuration configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8430",
    "datePublished": "2025-10-14T16:54:43.948Z",
    "dateReserved": "2025-07-31T18:25:10.514Z",
    "dateUpdated": "2025-10-15T13:13:42.544Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8429 (GCVE-0-2025-8429)

Vulnerability from cvelistv5 – Published: 2025-10-14 15:29 – Updated: 2025-10-15 13:14
VLAI?
Title
A user with elevated privileges can inject XSS in the ACL Action access configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8429",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:08:27.369444Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:08:35.098Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "ACL Action access configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Action access configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:14:03.171Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8429-centreon-web-all-versions-medium-severity-5119"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the ACL Action access configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8429",
    "datePublished": "2025-10-14T15:29:56.095Z",
    "dateReserved": "2025-07-31T18:24:05.148Z",
    "dateUpdated": "2025-10-15T13:14:03.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54893 (GCVE-0-2025-54893)

Vulnerability from cvelistv5 – Published: 2025-10-14 15:24 – Updated: 2025-10-15 13:13
VLAI?
Title
A user with elevated privileges can inject XSS in the Hosts templates configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:07:58.282510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:08:06.222Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Hosts templates configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (Hosts templates configuration modules) allows Stored \n\n XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:13:00.967Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54893-centreon-web-all-versions-medium-severity-5120"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the Hosts templates configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54893",
    "datePublished": "2025-10-14T15:24:24.017Z",
    "dateReserved": "2025-07-31T18:22:28.421Z",
    "dateUpdated": "2025-10-15T13:13:00.967Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54891 (GCVE-0-2025-54891)

Vulnerability from cvelistv5 – Published: 2025-10-14 15:07 – Updated: 2025-10-15 13:12
VLAI?
Title
A user with elevated privileges can inject XSS in the ACL Resource Access configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:06:28.726983Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:06:36.058Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "ACL Resource access configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (ACL Resource access configuration modules) allows Stored \n\nXSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:12:10.485Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54891-centreon-web-all-versions-medium-severity-5122"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the ACL Resource Access configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54891",
    "datePublished": "2025-10-14T15:07:01.145Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2025-10-15T13:12:10.485Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54892 (GCVE-0-2025-54892)

Vulnerability from cvelistv5 – Published: 2025-10-14 14:59 – Updated: 2025-10-15 13:12
VLAI?
Title
A user with elevated privileges can inject XSS in the SNMP traps group configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:05:09.568499Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:05:17.713Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "SNMP traps group configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:12:33.859Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54892-centreon-web-all-versions-medium-severity-5121"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the SNMP traps group configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54892",
    "datePublished": "2025-10-14T14:59:10.681Z",
    "dateReserved": "2025-07-31T18:22:28.420Z",
    "dateUpdated": "2025-10-15T13:12:33.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54889 (GCVE-0-2025-54889)

Vulnerability from cvelistv5 – Published: 2025-10-14 14:54 – Updated: 2025-10-15 13:11
VLAI?
Title
A user with elevated privileges can inject XSS in the SNMP traps manufacturer configuration page
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
Marcelo Queiroz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54889",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:04:42.477460Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:04:50.878Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "SNMP traps manufacturer configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marcelo Queiroz"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps manufacturer configuration modules) allows Stored XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T13:11:44.087Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54889-centreon-web-all-versions-medium-severity-5123"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A user with elevated privileges can inject XSS in the SNMP traps manufacturer configuration page",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-54889",
    "datePublished": "2025-10-14T14:54:31.311Z",
    "dateReserved": "2025-07-31T18:22:28.419Z",
    "dateUpdated": "2025-10-15T13:11:44.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5946 (GCVE-0-2025-5946)

Vulnerability from cvelistv5 – Published: 2025-10-14 14:29 – Updated: 2025-10-14 16:03
VLAI?
Title
RCE via the poller reload feature available only to user with high privilege
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
h00die-gr3y a.k.a. Hanko van Giessen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5946",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:03:02.831678Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:03:12.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Poller reload setup in the configuration"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "h00die-gr3y a.k.a. Hanko van Giessen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInfra Monitoring \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e(Poller reload setup in the configuration modules) allows OS Command Injection.\u003c/span\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\u003c/span\u003e\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T14:29:00.514Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-versions-high-severity-5104"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via the poller reload feature available only to user with high privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-5946",
    "datePublished": "2025-10-14T14:29:00.514Z",
    "dateReserved": "2025-06-09T17:09:29.545Z",
    "dateUpdated": "2025-10-14T16:03:12.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8428 (GCVE-0-2025-8428)

Vulnerability from cvelistv5 – Published: 2025-10-14 14:22 – Updated: 2025-10-14 16:01
VLAI?
Title
XSS found in the HTTP loader widget
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Centreon Infra Monitoring Affected: 24.10.0 , < 24.10.13 (custom)
Affected: 24.04.0 , < 24.04.18 (custom)
Affected: 23.10.0 , < 23.10.28 (custom)
Create a notification for this product.
Credits
SpawnZii
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8428",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T16:01:45.943850Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T16:01:54.470Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "HTTP Loader widget"
          ],
          "product": "Infra Monitoring",
          "vendor": "Centreon",
          "versions": [
            {
              "lessThan": "24.10.13",
              "status": "affected",
              "version": "24.10.0",
              "versionType": "custom"
            },
            {
              "lessThan": "24.04.18",
              "status": "affected",
              "version": "24.04.0",
              "versionType": "custom"
            },
            {
              "lessThan": "23.10.28",
              "status": "affected",
              "version": "23.10.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SpawnZii"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T14:22:03.098Z",
        "orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "shortName": "Centreon"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://github.com/centreon/centreon/releases"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8428-centreon-web-all-versions-medium-severity-5103"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "XSS found in the HTTP loader widget",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
    "assignerShortName": "Centreon",
    "cveId": "CVE-2025-8428",
    "datePublished": "2025-10-14T14:22:03.098Z",
    "dateReserved": "2025-07-31T18:23:59.321Z",
    "dateUpdated": "2025-10-14T16:01:54.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}