Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for carescape_b850_monitor_firmware by gehealthcare

    FKIE_CVE-2020-6965

    Vulnerability from fkie_nvd - Published: 2020-01-24 18:15 - Updated: 2026-06-17 03:24
    Summary
    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59",
                  "versionEndIncluding": "4.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b450_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9607F33-BAC9-4F45-8685-9091CBBF4336",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b450_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDF68D5F-E436-492A-965E-0E9E254ACBFF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF1DCCAF-A4E6-484B-953D-9352C85DE894",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9A5B8CF-5214-4056-87CD-CD1F98142BD6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b650_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B149BFB-BB31-4FFC-BC4D-299AB326136D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BDE014C2-9814-4137-9270-9B2AB55D3ABF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD10A852-3E11-4436-B771-53A9947A355E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b850_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7B8CA355-421A-44DE-A7EA-0BC0ACFDD697",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610",
                  "versionEndIncluding": "4.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."
        },
        {
          "lang": "es",
          "value": "En ApexPro Telemetry Server Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Central Station (CSCS) Versiones 1.X, B450 Versi\u00f3n 2.X, B650 Versi\u00f3n 1.X, B650 Versi\u00f3n 2.X, B850 Versi\u00f3n 1.X, B850 Versi\u00f3n 2.X, una vulnerabilidad en el mecanismo de actualizaci\u00f3n de software permite a un atacante autenticado cargar archivos arbitrarios en el sistema por medio de un paquete de actualizaci\u00f3n dise\u00f1ado."
        }
      ],
      "id": "CVE-2020-6965",
      "lastModified": "2026-06-17T03:24:01.800",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.9,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-01-24T18:15:12.647",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-434"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            },
            {
              "lang": "en",
              "value": "CWE-434"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-6962

    Vulnerability from fkie_nvd - Published: 2020-01-24 17:15 - Updated: 2026-06-17 03:24
    Summary
    In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server,v4.2 \u0026 prior,Clinical Information Center,v4.X \u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59",
                  "versionEndIncluding": "4.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:4.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A7CD125-E50C-4A1E-BF2B-318162D634CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b450_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9607F33-BAC9-4F45-8685-9091CBBF4336",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b450_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDF68D5F-E436-492A-965E-0E9E254ACBFF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF1DCCAF-A4E6-484B-953D-9352C85DE894",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9A5B8CF-5214-4056-87CD-CD1F98142BD6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b650_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B149BFB-BB31-4FFC-BC4D-299AB326136D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BDE014C2-9814-4137-9270-9B2AB55D3ABF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD10A852-3E11-4436-B771-53A9947A355E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_b850_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7B8CA355-421A-44DE-A7EA-0BC0ACFDD697",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9304DE75-4BCB-4C13-97D5-547195441591",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43F897B5-1F21-466D-A99C-2E6A98E93FFA",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610",
                  "versionEndIncluding": "4.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:4.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "13F7A4D6-2B11-4B74-A645-8AB1ADDBBC95",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
        },
        {
          "lang": "es",
          "value": "En ApexPro Telemetry Server, Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Telemetry Server Versi\u00f3n 4.3, CARESCAPE Central Station (CSCS) Versiones 1.X, CARESCAPE Central Station (CSCS) Versiones 2.X, B450 Versi\u00f3n 2.X, B650 Versi\u00f3n 1.X, B650 Versi\u00f3n 2.X, B850 Versi\u00f3n 1.X, B850 Versi\u00f3n 2.X, se presenta una vulnerabilidad de comprobaci\u00f3n de entrada en la utilidad de configuraci\u00f3n del sistema basada en web que podr\u00eda permitir a un atacante obtener una ejecuci\u00f3n arbitraria de c\u00f3digo remoto."
        }
      ],
      "id": "CVE-2020-6962",
      "lastModified": "2026-06-17T03:24:01.457",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 10.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-01-24T17:15:13.127",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2020-6965 (GCVE-0-2020-6965)

    Vulnerability from nvd – Published: 2020-01-24 17:06 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
    Severity
    No CVSS data available.
    CWE
    • CWE-434 - UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors Affected: ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server, v4.2 & prior,Clinical Information Center,v4.X& 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.543Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:06:53.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6965",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6965",
        "datePublished": "2020-01-24T17:06:53.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.543Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6962 (GCVE-0-2020-6962)

    Vulnerability from nvd – Published: 2020-01-24 16:07 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors Affected: ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server,v4.2 & prior,Clinical Information Center,v4.X & 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:01.628Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server,v4.2 \u0026 prior,Clinical Information Center,v4.X \u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "IMPROPER INPUT VALIDATION CWE-20",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T16:07:54.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6962",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server,v4.2 \u0026 prior,Clinical Information Center,v4.X \u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER INPUT VALIDATION CWE-20"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6962",
        "datePublished": "2020-01-24T16:07:54.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:01.628Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6965 (GCVE-0-2020-6965)

    Vulnerability from cvelistv5 – Published: 2020-01-24 17:06 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
    Severity
    No CVSS data available.
    CWE
    • CWE-434 - UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors Affected: ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server, v4.2 & prior,Clinical Information Center,v4.X& 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.543Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:06:53.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6965",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6965",
        "datePublished": "2020-01-24T17:06:53.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.543Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6962 (GCVE-0-2020-6962)

    Vulnerability from cvelistv5 – Published: 2020-01-24 16:07 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors Affected: ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server,v4.2 & prior,Clinical Information Center,v4.X & 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:01.628Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server,v4.2 \u0026 prior,Clinical Information Center,v4.X \u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "IMPROPER INPUT VALIDATION CWE-20",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T16:07:54.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6962",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server,v4.2 \u0026 prior,Clinical Information Center,v4.X \u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER INPUT VALIDATION CWE-20"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6962",
        "datePublished": "2020-01-24T16:07:54.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:01.628Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }