Search
Find a vulnerability
Search criteria
8 vulnerabilities found for cMT3092X firmware by Weintek
CVE-2026-61892 (GCVE-0-2026-61892)
Vulnerability from nvd – Published: 2026-07-24 22:16 – Updated: 2026-07-27 14:31
VLAI
EPSS
VEX
Title
Weintek cMT3092X Incorrect Permission Assignment for Critical Resource
Summary
Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:30 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:30:54.856897Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:31:09.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:16:58.155Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Incorrect Permission Assignment for Critical Resource",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-61892",
"datePublished": "2026-07-24T22:16:58.155Z",
"dateReserved": "2026-07-16T16:04:55.185Z",
"dateUpdated": "2026-07-27T14:31:09.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61886 (GCVE-0-2026-61886)
Vulnerability from nvd – Published: 2026-07-24 22:10 – Updated: 2026-07-27 14:32
VLAI
EPSS
VEX
Title
Weintek cMT3092X Plaintext Storage of a Password
Summary
Weintek cMT3092X HMI stores user account passwords in plaintext.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:31 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61886",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:31:58.631398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:32:07.257Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI stores user account passwords in plaintext.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI stores user account passwords in plaintext."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:10:03.065Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Plaintext Storage of a Password",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-61886",
"datePublished": "2026-07-24T22:10:03.065Z",
"dateReserved": "2026-07-16T16:04:55.182Z",
"dateUpdated": "2026-07-27T14:32:07.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-60135 (GCVE-0-2026-60135)
Vulnerability from nvd – Published: 2026-07-24 22:06 – Updated: 2026-07-27 14:32
VLAI
EPSS
VEX
Title
Weintek cMT3092X Incorrect User Management
Summary
An attacker can modify data that should be restricted to read‑only access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:32 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-60135",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:32:24.119978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:32:32.622Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eAn attacker can modify data that should be restricted to read\u2011only access.\u003c/span\u003e"
}
],
"value": "An attacker can modify data that should be restricted to read\u2011only access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-286",
"description": "CWE-286",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:06:12.337Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Incorrect User Management",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-60135",
"datePublished": "2026-07-24T22:06:12.337Z",
"dateReserved": "2026-07-16T16:04:55.177Z",
"dateUpdated": "2026-07-27T14:32:32.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-60134 (GCVE-0-2026-60134)
Vulnerability from nvd – Published: 2026-07-24 22:20 – Updated: 2026-07-27 14:30
VLAI
EPSS
VEX
Title
Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision
Summary
Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:30 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-60134",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:30:24.338784Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:30:33.224Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-784",
"description": "CWE-784",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:20:20.024Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-60134",
"datePublished": "2026-07-24T22:20:20.024Z",
"dateReserved": "2026-07-16T16:04:55.188Z",
"dateUpdated": "2026-07-27T14:30:33.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-60134 (GCVE-0-2026-60134)
Vulnerability from cvelistv5 – Published: 2026-07-24 22:20 – Updated: 2026-07-27 14:30
VLAI
EPSS
VEX
Title
Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision
Summary
Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:30 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-60134",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:30:24.338784Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:30:33.224Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-784",
"description": "CWE-784",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:20:20.024Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-60134",
"datePublished": "2026-07-24T22:20:20.024Z",
"dateReserved": "2026-07-16T16:04:55.188Z",
"dateUpdated": "2026-07-27T14:30:33.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61892 (GCVE-0-2026-61892)
Vulnerability from cvelistv5 – Published: 2026-07-24 22:16 – Updated: 2026-07-27 14:31
VLAI
EPSS
VEX
Title
Weintek cMT3092X Incorrect Permission Assignment for Critical Resource
Summary
Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:30 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:30:54.856897Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:31:09.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:16:58.155Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Incorrect Permission Assignment for Critical Resource",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-61892",
"datePublished": "2026-07-24T22:16:58.155Z",
"dateReserved": "2026-07-16T16:04:55.185Z",
"dateUpdated": "2026-07-27T14:31:09.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61886 (GCVE-0-2026-61886)
Vulnerability from cvelistv5 – Published: 2026-07-24 22:10 – Updated: 2026-07-27 14:32
VLAI
EPSS
VEX
Title
Weintek cMT3092X Plaintext Storage of a Password
Summary
Weintek cMT3092X HMI stores user account passwords in plaintext.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:31 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61886",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:31:58.631398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:32:07.257Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek cMT3092X HMI stores user account passwords in plaintext.\u003c/span\u003e"
}
],
"value": "Weintek cMT3092X HMI stores user account passwords in plaintext."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:10:03.065Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Plaintext Storage of a Password",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-61886",
"datePublished": "2026-07-24T22:10:03.065Z",
"dateReserved": "2026-07-16T16:04:55.182Z",
"dateUpdated": "2026-07-27T14:32:07.257Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-60135 (GCVE-0-2026-60135)
Vulnerability from cvelistv5 – Published: 2026-07-24 22:06 – Updated: 2026-07-27 14:32
VLAI
EPSS
VEX
Title
Weintek cMT3092X Incorrect User Management
Summary
An attacker can modify data that should be restricted to read‑only access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-27 14:32 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weintek | cMT3092X firmware |
Affected:
0 , < 20210218
(custom)
|
|
| Weintek | EasyWeb |
Affected:
0 , < v2.1.20
(custom)
Unaffected: 2.3.17-typeb |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-60135",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-27T14:32:24.119978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-27T14:32:32.622Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "cMT3092X firmware",
"vendor": "Weintek",
"versions": [
{
"lessThan": "20210218",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EasyWeb",
"vendor": "Weintek",
"versions": [
{
"lessThan": "v2.1.20",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eAn attacker can modify data that should be restricted to read\u2011only access.\u003c/span\u003e"
}
],
"value": "An attacker can modify data that should be restricted to read\u2011only access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-286",
"description": "CWE-286",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T22:06:12.337Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
}
],
"value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"title": "Weintek cMT3092X Incorrect User Management",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-60135",
"datePublished": "2026-07-24T22:06:12.337Z",
"dateReserved": "2026-07-16T16:04:55.177Z",
"dateUpdated": "2026-07-27T14:32:32.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}