Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

10 vulnerabilities found for bl-x26_da3_firmware by b-link

CVE-2025-45988 (GCVE-0-2025-45988)

Vulnerability from nvd – Published: 2025-06-13 00:00 – Updated: 2025-06-13 15:06
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45988",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T15:05:11.705282Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T15:06:37.196Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:21.904Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_cmd%20Indicates%20the%20unauthorized%20command%20injection/The%20LB-LINK_cmd%20command%20is%20used%20to%20inject%20information.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45988",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T15:06:37.196Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45987 (GCVE-0-2025-45987)

Vulnerability from nvd – Published: 2025-06-13 00:00 – Updated: 2025-06-13 15:03
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45987",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T15:01:29.839740Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T15:03:03.641Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:20.882Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_dns1%20Unauthorized%20command%20injection/The%20LB-LINK_dns1%20command%20is%20used%20to%20inject%20the%20information.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45987",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T15:03:03.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45986 (GCVE-0-2025-45986)

Vulnerability from nvd – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:59
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45986",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:58:55.450224Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:59:24.580Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:20.100Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_mac%20Unauthorized%20command%20injection/LB-LINK_mac%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45986",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:59:24.580Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45985 (GCVE-0-2025-45985)

Vulnerability from nvd – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:51
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45985",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:47:55.878294Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:51:09.050Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:19.167Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_enable%20Unauthorized%20command%20injection/LB-LINK_enable%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45985",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:51:09.050Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45984 (GCVE-0-2025-45984)

Vulnerability from nvd – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:15
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45984",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:13:00.770998Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:15:14.650Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:18.203Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_routepwd%20Indicates%20the%20unauthorized%20command%20injection/LB-LINK_routepwd%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45984",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:15:14.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45986 (GCVE-0-2025-45986)

Vulnerability from cvelistv5 – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:59
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45986",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:58:55.450224Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:59:24.580Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:20.100Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_mac%20Unauthorized%20command%20injection/LB-LINK_mac%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45986",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:59:24.580Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45988 (GCVE-0-2025-45988)

Vulnerability from cvelistv5 – Published: 2025-06-13 00:00 – Updated: 2025-06-13 15:06
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45988",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T15:05:11.705282Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T15:06:37.196Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:21.904Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_cmd%20Indicates%20the%20unauthorized%20command%20injection/The%20LB-LINK_cmd%20command%20is%20used%20to%20inject%20information.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45988",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T15:06:37.196Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45987 (GCVE-0-2025-45987)

Vulnerability from cvelistv5 – Published: 2025-06-13 00:00 – Updated: 2025-06-13 15:03
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45987",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T15:01:29.839740Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T15:03:03.641Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:20.882Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_dns1%20Unauthorized%20command%20injection/The%20LB-LINK_dns1%20command%20is%20used%20to%20inject%20the%20information.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45987",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T15:03:03.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45984 (GCVE-0-2025-45984)

Vulnerability from cvelistv5 – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:15
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45984",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:13:00.770998Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:15:14.650Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:18.203Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_routepwd%20Indicates%20the%20unauthorized%20command%20injection/LB-LINK_routepwd%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45984",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:15:14.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45985 (GCVE-0-2025-45985)

Vulnerability from cvelistv5 – Published: 2025-06-13 00:00 – Updated: 2025-06-13 14:51
VLAI?
Summary
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45985",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T14:47:55.878294Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-13T14:51:09.050Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T11:30:19.167Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_enable%20Unauthorized%20command%20injection/LB-LINK_enable%20command%20injection.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45985",
    "datePublished": "2025-06-13T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-06-13T14:51:09.050Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",