Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
10 vulnerabilities found for bizhub series by KONICA MINOLTA, INC.
CVE-2021-20872 (GCVE-0-2021-20872)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
Severity ?
No CVSS data available.
CWE
- Protection mechanism failure
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Protection mechanism failure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:27.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Protection mechanism failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20872",
"datePublished": "2022-01-04T03:05:27.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20871 (GCVE-0-2021-20871)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:25.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20871",
"datePublished": "2022-01-04T03:05:25.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20870 (GCVE-0-2021-20870)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
Severity ?
No CVSS data available.
CWE
- Improper handling of exceptional conditions
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper handling of exceptional conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:24.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20870",
"datePublished": "2022-01-04T03:05:24.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20869 (GCVE-0-2021-20869)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:22.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20869",
"datePublished": "2022-01-04T03:05:22.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:22.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20868 (GCVE-0-2021-20868)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
Severity ?
No CVSS data available.
CWE
- Incorrect authorization
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:20.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20868",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20868",
"datePublished": "2022-01-04T03:05:20.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20872 (GCVE-0-2021-20872)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
Severity ?
No CVSS data available.
CWE
- Protection mechanism failure
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Protection mechanism failure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:27.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Protection mechanism failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20872",
"datePublished": "2022-01-04T03:05:27.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20871 (GCVE-0-2021-20871)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:25.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20871",
"datePublished": "2022-01-04T03:05:25.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20870 (GCVE-0-2021-20870)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
Severity ?
No CVSS data available.
CWE
- Improper handling of exceptional conditions
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper handling of exceptional conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:24.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20870",
"datePublished": "2022-01-04T03:05:24.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20869 (GCVE-0-2021-20869)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:22.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20869",
"datePublished": "2022-01-04T03:05:22.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:22.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20868 (GCVE-0-2021-20868)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
Severity ?
No CVSS data available.
CWE
- Incorrect authorization
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:20.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20868",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20868",
"datePublished": "2022-01-04T03:05:20.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:53:23.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}