Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for berlin-l21hn_firmware by huawei

    CVE-2017-17158 (GCVE-0-2017-17158)

    Vulnerability from nvd – Published: 2018-05-24 14:00 – Updated: 2024-08-05 20:43
    VLAI
    Summary
    Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user's smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure.
    Severity
    No CVSS data available.
    CWE
    • information exposure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Huawei Technologies Co., Ltd. Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A Affected: The versions before Berlin-L21HNC185B381
    Affected: The versions before Prague-AL00AC00B223
    Affected: The versions before Prague-AL00BC00B223
    Affected: The versions before Prague-AL00CC00B223
    Affected: The versions before Prague-L31C432B208
    Affected: The versions before Prague-TL00AC01B223
    Create a notification for this product.
    Date Public
    2018-05-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T20:43:59.933Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A",
              "vendor": "Huawei Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "The versions before Berlin-L21HNC185B381"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00AC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00BC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00CC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-L31C432B208"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-TL00AC01B223"
                }
              ]
            }
          ],
          "datePublic": "2018-05-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user\u0027s smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "information exposure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T13:57:01.000Z",
            "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
            "shortName": "huawei"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@huawei.com",
              "ID": "CVE-2017-17158",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "The versions before Berlin-L21HNC185B381"
                              },
                              {
                                "version_value": "The versions before Prague-AL00AC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-AL00BC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-AL00CC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-L31C432B208"
                              },
                              {
                                "version_value": "The versions before Prague-TL00AC01B223"
                              },
                              {
                                "version_value": "The versions before Prague-TL00AC01B223"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Huawei Technologies Co., Ltd."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user\u0027s smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "information exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en",
                  "refsource": "CONFIRM",
                  "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "assignerShortName": "huawei",
        "cveId": "CVE-2017-17158",
        "datePublished": "2018-05-24T14:00:00.000Z",
        "dateReserved": "2017-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-05T20:43:59.933Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-2721 (GCVE-0-2017-2721)

    Vulnerability from nvd – Published: 2017-11-22 19:00 – Updated: 2024-09-16 19:56
    VLAI
    Summary
    Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed.
    Severity
    No CVSS data available.
    CWE
    • FRP Bypass
    Assigner
    References
    Impacted products
    Vendor Product Version
    Huawei Technologies Co., Ltd. Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19, Affected: Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,
    Create a notification for this product.
    Date Public
    2017-11-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T14:02:07.541Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19,",
              "vendor": "Huawei Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,"
                }
              ]
            }
          ],
          "datePublic": "2017-11-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "FRP Bypass",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-22T18:57:01.000Z",
            "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
            "shortName": "huawei"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@huawei.com",
              "DATE_PUBLIC": "2017-11-15T00:00:00",
              "ID": "CVE-2017-2721",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19,",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Huawei Technologies Co., Ltd."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "FRP Bypass"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en",
                  "refsource": "CONFIRM",
                  "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "assignerShortName": "huawei",
        "cveId": "CVE-2017-2721",
        "datePublished": "2017-11-22T19:00:00.000Z",
        "dateReserved": "2016-12-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:56:17.268Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-17158 (GCVE-0-2017-17158)

    Vulnerability from cvelistv5 – Published: 2018-05-24 14:00 – Updated: 2024-08-05 20:43
    VLAI
    Summary
    Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user's smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure.
    Severity
    No CVSS data available.
    CWE
    • information exposure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Huawei Technologies Co., Ltd. Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A Affected: The versions before Berlin-L21HNC185B381
    Affected: The versions before Prague-AL00AC00B223
    Affected: The versions before Prague-AL00BC00B223
    Affected: The versions before Prague-AL00CC00B223
    Affected: The versions before Prague-L31C432B208
    Affected: The versions before Prague-TL00AC01B223
    Create a notification for this product.
    Date Public
    2018-05-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T20:43:59.933Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A",
              "vendor": "Huawei Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "The versions before Berlin-L21HNC185B381"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00AC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00BC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-AL00CC00B223"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-L31C432B208"
                },
                {
                  "status": "affected",
                  "version": "The versions before Prague-TL00AC01B223"
                }
              ]
            }
          ],
          "datePublic": "2018-05-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user\u0027s smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "information exposure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T13:57:01.000Z",
            "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
            "shortName": "huawei"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@huawei.com",
              "ID": "CVE-2017-17158",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Berlin-L21HN; Prague-AL00A; Prague-AL00B; Prague-AL00C; Prague-L31; Prague-TL00A; Prague-TL10A",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "The versions before Berlin-L21HNC185B381"
                              },
                              {
                                "version_value": "The versions before Prague-AL00AC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-AL00BC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-AL00CC00B223"
                              },
                              {
                                "version_value": "The versions before Prague-L31C432B208"
                              },
                              {
                                "version_value": "The versions before Prague-TL00AC01B223"
                              },
                              {
                                "version_value": "The versions before Prague-TL00AC01B223"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Huawei Technologies Co., Ltd."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Some Huawei smart phones with the versions before Berlin-L21HNC185B381; the versions before Prague-AL00AC00B223; the versions before Prague-AL00BC00B223; the versions before Prague-AL00CC00B223; the versions before Prague-L31C432B208; the versions before Prague-TL00AC01B223; the versions before Prague-TL00AC01B223 have an information exposure vulnerability. When the user\u0027s smart phone connects to the malicious device for charging, an unauthenticated attacker may activate some specific function by sending some specially crafted messages. Due to insufficient input validation of the messages, successful exploit may cause information exposure."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "information exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en",
                  "refsource": "CONFIRM",
                  "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-phone-en"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "assignerShortName": "huawei",
        "cveId": "CVE-2017-17158",
        "datePublished": "2018-05-24T14:00:00.000Z",
        "dateReserved": "2017-12-04T00:00:00.000Z",
        "dateUpdated": "2024-08-05T20:43:59.933Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-2721 (GCVE-0-2017-2721)

    Vulnerability from cvelistv5 – Published: 2017-11-22 19:00 – Updated: 2024-09-16 19:56
    VLAI
    Summary
    Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed.
    Severity
    No CVSS data available.
    CWE
    • FRP Bypass
    Assigner
    References
    Impacted products
    Vendor Product Version
    Huawei Technologies Co., Ltd. Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19, Affected: Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,
    Create a notification for this product.
    Date Public
    2017-11-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T14:02:07.541Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19,",
              "vendor": "Huawei Technologies Co., Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,"
                }
              ]
            }
          ],
          "datePublic": "2017-11-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "FRP Bypass",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-22T18:57:01.000Z",
            "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
            "shortName": "huawei"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@huawei.com",
              "DATE_PUBLIC": "2017-11-15T00:00:00",
              "ID": "CVE-2017-2721",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Berlin-L21,Berlin-L21HN,Berlin-L22,Berlin-L22HN,Berlin-L23,Berlin-L24HN,FRD-L02,FRD-L04,FRD-L09,FRD-L14,FRD-L19,",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130,"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Huawei Technologies Co., Ltd."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "FRP Bypass"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en",
                  "refsource": "CONFIRM",
                  "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170920-01-frpbypass-en"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "assignerShortName": "huawei",
        "cveId": "CVE-2017-2721",
        "datePublished": "2017-11-22T19:00:00.000Z",
        "dateReserved": "2016-12-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:56:17.268Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }